Slack length of gastrocnemius medialis and Achilles tendon occurs at different ankle angles
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 3,673
Supersonic shear imaging: a new technique for soft tissue elasticity mapping
Bercoff, J., Tanter, M., & Fink, M. (2004) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1295425 · Cited by 2,476 · cited 1×
“SuperLinear 15-4, Vermon, Tours, France) was used in SSI mode (musculo-skeletal preset) as previously described (Bercoff et al., 2004).”
MethodHoy, M. G., Zajac, F. E., & Gordon, M. E. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90349-8 · Cited by 525 · cited 1×
“Although this is a crucial parameter used in muscle models (Ackland et al., 2012; Garner and Pandy, 2003; Hoy et al., 1990; Zajac, 1989) this is one of the most difficult measures to estimate in vivo (Garner and Pandy, 2003).”
MethodMaganaris, C. N., Baltzopoulos, V., & Sargeant, A. J. (1998) · The Journal of Physiology · doi:10.1111/j.1469-7793.1998.603be.x · Cited by 402 · cited 1×
“As it has been shown that the two heads of gastrocnemii behave similarly when passively lengthened (Maganaris et al., 1998), it is unlikely that the slack length of the lateral head of gastrocnemius would occur at a different ankle angle than the medial head.”
BackgroundMaïsetti, O., Hug, F., Bouillard, K., & Nordez, A. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.01.009 · Cited by 263 · cited 4×
“Taking advantage of this technique, muscle slack length was determined on gastrocnemius medialis (Maisetti et al., 2012) and on each head of biceps brachii (Lacourpaille et al.”
MethodResultInfluentialSelf-citationEstimation of Musculotendon Properties in the Human Upper Limb
Garner, B. A., & Pandy, M. G. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1540105 · Cited by 214 · cited 2×
“Although this is a crucial parameter used in muscle models (Ackland et al., 2012; Garner and Pandy, 2003; Hoy et al., 1990; Zajac, 1989) this is one of the most difficult measures to estimate in vivo (Garner and Pandy, 2003).”
BackgroundMethodRelationship between shear elastic modulus and passive muscle force: An ex-vivo study
Koo, T. K., Guo, J.-Y., Cohen, J. H., & Parker, K. J. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.05.016 · Cited by 197 · cited 1×
“We have recently shown that an ultrasound shear wave elastographic technique called “supersonic shear imaging” (SSI) is able to accurately quantify shear elastic modulus of a targeted muscle during passive stretching (Koo et al., 2013; Maisetti et al., 2012).”
Estimation of Individual Muscle Force Using Elastography
Bouillard, K., Nordez, A., & Hug, F. (2011) · PLoS ONE · doi:10.1371/journal.pone.0029261 · Cited by 187
Self-citationAckland, D. C., Lin, Y.-C., & Pandy, M. G. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.02.023 · Cited by 182
Riemann, B. L., DeMont, R. G., Ryu, K., & Lephart, S. M. (2001) · Europe PMC (PubMed Central) · Cited by 181
Barber, L. A., Barrett, R., & Lichtwark, G. A. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.07.018 · Cited by 155 · cited 1×
“Some studies determined the slack length as the muscle–tendon length at which the passive joint torque first exceeds zero (Barber et al., 2012; Muraoka et al., 2004, 2005).”
BackgroundInfluence of tendon slack on electromechanical delay in the human medial gastrocnemius in vivo
Muraoka, T., Muramatsu, T., Fukunaga, T., & Kanehisa, H. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01015.2002 · Cited by 144
Three‐dimensional reconstructions of the Achilles tendon insertion in man
Milz, S., Rufai, A., Büttner, A., Putz, R. V., Ralphs, J. R., & Benjamin, M. (2002) · Journal of Anatomy · doi:10.1046/j.0021-8782.2001.00016.x · Cited by 130
Bouillard, K., Hug, F., Guével, A., & Nordez, A. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00858.2012 · Cited by 118 · cited 1×
“There is experimental evidence that the shear elastic modulus measured by SSI is linearly related to muscle stress during both isometric contraction (Bouillard et al., 2011, 2012) and passive stretching (Maisetti et al., 2012). Taking advantage of this technique, Maisetti et al., (2012) showed that the slack length of…”
ResultSelf-citationHerbert, R., Clarke, J., Kwah, L. K., Diong, J. H. L., Martin, J., Clarke, E., Bilston, L. E., & Gandevia, S. C. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2011.212175 · Cited by 108 · cited 1×
“Other studies have used ultrasonography to isolate the slack length of one muscle–tendon unit (Herbert et al., 2011; Hoang et al., 2007).”
BackgroundA new method for measuring passive length–tension properties of human gastrocnemius muscle in vivo
Hoang, P. D., Gorman, R. B., Todd, G., Gandevia, S. C., & Herbert, R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.046 · Cited by 105
Hoang, P. D., Herbert, R., Todd, G., Gorman, R. B., & Gandevia, S. C. (2007) · Journal of Experimental Biology · doi:10.1242/jeb.002204 · Cited by 101 · cited 1×
“Other studies have used ultrasonography to isolate the slack length of one muscle–tendon unit (Herbert et al., 2011; Hoang et al., 2007).”
BackgroundInfluence of Passive Muscle Tension on Electromechanical Delay in Humans
Lacourpaille, L., Hug, F., & Nordez, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0053159 · Cited by 75 · cited 2×
“The ankle angle corresponding to the tendon and muscle slack length was visually determined (blind to structure, knee angle and trial) by an experienced examiner (Lacourpaille et al., 2013).”
BackgroundMethodSelf-citationNordez, A., McNair, P. J., Casari, P., & Cornu, C. (2008) · International Journal of Sports Medicine · doi:10.1055/s-2007-964980 · Cited by 53
Self-citation
Cited by
Van Hooren, B., & Zolotarjova, J. (2017) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001913 · Cited by 328
Creze, M., Nordez, A., Soubeyrand, M., Rocher, L., Maître, X., & Bellin, M.-F. (2018) · Skeletal Radiology · doi:10.1007/s00256-017-2843-y · Cited by 242
Self-citationBrum, J., Bernal, M., Gennisson, J. L., & Tanter, M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/3/505 · Cited by 190
“As demonstrated by Hug et al (2013), not only the angle between the foot and the tibia plays a role on the Achilles tendon elasticity assessment, but also the knee angle.”
BackgroundSpatial variations in Achilles tendon shear wave speed
DeWall, R. J., Slane, L. C., Lee, K. S., & Thelen, D. G. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.05.008 · Cited by 105
“Shear wave speed in the free Achilles tendon has been measured (Arda et al., 2011; Aubry et al., 2013; Brum et al., 2014; Chen et al., 2013; Hug et al., 2013) and has been shown to increase as the tendon is stretched (Aubry et al.”
Influential
Metadata
- Authors
- Hug, F., Lacourpaille, L., Maïsetti, O., & Nordez, A.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2013-09
- Volume
- 46
- Issue
- 14
- Pages
- 2534-2538
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1989727952
- Cited by
- 162
- References
- 19
- FWCI
- 8.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.