CoChat

Effects of a passive exoskeleton on the mechanical loading of the low back in static holding tasks

Open access
Koopman, Axel S., Kingma, Idsart, Faber, Gert S., de Looze, Michiel P., van Dieën, Jaap H. · 2019 · Journal of Biomechanics
Cited by 192

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

With mechanical loading as the main risk factor for LBP in mind, exoskeletons are designed to reduce the load on the back by taking over a part of the required moment. The present study assessed the effect of a passive exoskeleton on back and abdominal muscle activation, hip and lumbar flexion and on the contribution of both the human and the exoskeleton to the L5/S1 net moment, during static bending at five different hand heights. Two configurations of the exoskeleton (LOW & HIGH) differing in angle-torque characteristics were tested. L5/S1 moments generated by the subjects were significantly reduced (15-20% for the most effective type) at all hand heights. LOW generated 4-11 Nm more support than HIGH at 50%, 25% and 0% upright stance hand height and HIGH generated 4-5 Nm more support than LOW at 100% and 75%. Significant reductions (11-57%) in back muscle activity were found compared to WITHOUT for both exoskeletons for some conditions. However, EMG reductions compared to WITHOUT were highly variable across subjects and not always significant. The device allowed for substantial lumbar bending (up to 70°) so that a number of participants showed the flexion-relaxation phenomenon, which prevented further reduction of back EMG by the device and even an increase from 2% to 6% MVC in abdominal activity at 25% hand height. These results indicate that flexion relaxation and its interindividual variation should be considered in future exoskeleton developments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jbiomech.2018.11.033

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 192

Metadata

Authors
Koopman, A. S., Kingma, I., Faber, G. S., de Looze, M. P., & van Dieën, J. H.
Venue
Journal of Biomechanics
Publisher
Elsevier BV
Published
2019-01
Volume
83
Pages
97-103
ISSN
0021-9290 (ISSN-L)
OpenAlex
W2902417498
Cited by
192
References
26
FWCI
7.08
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of a passive exoskeleton on the mechanical loading of the low back in static holding tasks. https://app.cochat.ai/papers/10.1016/j.jbiomech.2018.11.033
The paper
Koopman, A. S., Kingma, I., Faber, G. S., de Looze, M. P., & van Dieën, J. H. (2019). Effects of a passive exoskeleton on the mechanical loading of the low back in static holding tasks. Journal of Biomechanics. https://doi.org/10.1016/j.jbiomech.2018.11.033

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.