Application of the 6-aminoquinolyl-N-hydroxysccinimidyl carbamate (AQC) reagent to the RP-HPLC determination of amino acids in infant foods
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The validation of a pre-column derivatization procedure with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) to the determination of the amino acid content by RP-HPLC with fluorescence detection (lambda excitation 250 nm, lambda emission 395 nm) in milk-cereal based infant foods was carried out. The analytical parameters: linearity (0.0025-0.2mM), precision of the method (0.2-3.5% variation coefficients), accuracy (derivatization: 86-106% average recovery and method: 88.3-118.2% average recovery) and the limits of detection (0.016-0.367 microM) and quantification (0.044-1.073 microM) were determined. Glutamic acid, proline and leucine were the most abundant amino acid whereas the lowest contents corresponded to tyrosine and cysteine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Official Methods of Analysis of AOAC International
Horwitz, W., & LATIMER, G. W. (2006) · Medical Entomology and Zoology · Cited by 11,183
Rapid analysis of amino acids using pre-column derivatization
Bidlingmeyer, B. A., Cohen, S. A., & Tarvin, T. L. (1984) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)85133-6 · Cited by 2,514
Official methods of analysis of AOAC International, 16th ed
(1997) · Choice Reviews Online · doi:10.5860/choice.35-0912 · Cited by 1,240
Cohen, S. A., & Michaud, D. P. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1270 · Cited by 980
Applications of amino acid derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate
Cohen, S. A., & De Antonis, K. M. (1994) · Journal of Chromatography A · doi:10.1016/0021-9673(93)e0821-b · Cited by 209
Heems, D., Luck, G., Fraudeau, C., & Vérette, E. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01007-8 · Cited by 101
Hong, J. (1994) · Journal of Chromatography A · doi:10.1016/0021-9673(94)80280-7 · Cited by 88
Vitamin Content and Amino Acid Composition of Pickled Garlic Processed with and without Fermentation
Montaño, A., Casado, F. J., de Castro, A., Sánchez, A. H., & Rejano, L. (2004) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf040210l · Cited by 77
RP-HPLC Determination of Tiger Nut and Orgeat Amino Acid Contents
Bosch, L., Alegría, A., & FARRÉ, R. (2005) · Food Science and Technology International · doi:10.1177/1082013205051266 · Cited by 73
Self-citationLiu, H. J., Chang, B. Y., Yan, H. W., Yu, F., & Liu, X. X. (1995) · Journal of AOAC International · doi:10.1093/jaoac/78.3.736
Cited by
Rutherfurd, S. M., & Gilani, G. S. (2009) · Current Protocols in Protein Science · doi:10.1002/0471140864.ps1109s58 · Cited by 196
“Bosch et al. (2006) tested the accuracy of the method when applied to infant formulas and pure proteins, and reported excellent overall (interday and intraday) precision for the method (0.24% to 3.49”
MethodInfluentialTibaldi, E., Chini Zittelli, G., Parisi, G., Bruno, M., Giorgi, G., Tulli, F., Venturini, S., Tredici, M. R., & Poli, B. M. (2015) · Aquaculture · doi:10.1016/j.aquaculture.2015.02.002 · Cited by 160
Application of UHPLC for the determination of free amino acids in different cheese varieties
Mayer, H. K., & Fiechter, G. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-6974-2 · Cited by 26
Metadata
- Authors
- Bosch, L., Alegría, A., & Farré, R.
- Venue
- Journal of Chromatography B
- Publisher
- Elsevier BV
- Published
- 2006-02
- Volume
- 831
- Issue
- 1-2
- Pages
- 176-183
- ISSN
- 1570-0232 (ISSN-L)
- OpenAlex
- W2026407790
- Cited by
- 201
- References
- 10
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.