Amino Acid Analysis
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Amino acid analysis is used to determine the amino acid content of amino acid–, peptide‐ and protein‐containing samples. With minor exceptions, proteins are long linear polymers of amino acids connected to each other via peptide bonds. The first step of amino acid analysis involves hydrolyzing these peptide bonds. The liberated amino acids are then separated, detected, and quantified. The method was first developed by Moore, Stein and coworkers in the 1950s using HCl acid hydrolysis, and, despite considerable effort by many workers, the basic methodology remains relatively unchanged. This unit provides an overview and strategic planning for amino acid analysis, discussing a range of methodologies and issues. In addition, several common methods used for analysis of L‐amino acids are described in detail, including: HCl acid hydrolysis, performic acid oxidation for methionine and cysteine analysis, base hydrolysis for tryptophan analysis, analysis of free amino acids, and analysis of reactive lysine. Curr. Protoc. Protein Sci. 58:11.9.1‐11.9.37. © 2009 by John Wiley & Sons, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrolysis and amino acid composition analysis of proteins
Fountoulakis, M., & Lahm, H.-W. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(98)00721-3 · Cited by 606 · cited 1×
“A considerable number of studies have been conducted to examine the efficacy of base hydrolysis, and these have been thoroughly reviewed (Molnár-Perl, 1997; Fountoulakis and Lahm, 1998).”
BackgroundBruce, S. J., Tavazzi, I., Parisod, V., Rezzi, S., Kochhar, S., & Guy, P. A. (2009) · Analytical Chemistry · doi:10.1021/ac8024569 · Cited by 321
Cited by
Villamil, O., Váquiro, H., & Solanilla, J. F. (2017) · Food Chemistry · doi:10.1016/j.foodchem.2016.12.057 · Cited by 310
Empirical evaluation of bone extraction protocols
Cleland, T. P., Voegele, K., & Schweitzer, M. H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031443 · Cited by 60
Tavakoli, Z., Kavoosi, G., Siahbalaei, R., & Karimi, J. (2025) · Applied Food Research · doi:10.1016/j.afres.2025.100741 · Cited by 27
Deuterium labeling enables proteome-wide turnover kinetics analysis in cell culture
Alamillo, L., Ng, D. C. M., Currie, J., Black, A., Pandi, B., Manda, V., Pavelka, J., Schaal, P., Travers, J. G., McKinsey, T. A., et al. (2025) · Cell Reports Methods · doi:10.1016/j.crmeth.2025.101104 · Cited by 6
Metadata
- Authors
- Rutherfurd, S. M., & Gilani, G. S.
- Venue
- Current Protocols in Protein Science
- Publisher
- Wiley
- Published
- 2009-11
- Volume
- 58
- Issue
- 1
- Pages
- 11.9.1-11.9.37
- ISSN
- 1934-3655 (ISSN-L)
- 1934-3663
- OpenAlex
- W1588747168
- Cited by
- 196
- References
- 2
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Amino Acid Analysis. https://app.cochat.ai/papers/10.1002/0471140864.ps1109s58
- The paper
- Rutherfurd, S. M., & Gilani, G. S. (2009). Amino Acid Analysis. Current Protocols in Protein Science. https://doi.org/10.1002/0471140864.ps1109s58
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.