Cited by 12Analytical Methods in PharmaceuticalsBiosimilars and Bioanalytical MethodsForensic Toxicology and Drug Analysis

Development and validation of a UPLC–MS/MS method for quantitation of droxidopa in human plasma: Application to a pharmacokinetic study

Wang, Haidong, Yang, Guangsheng, Zhou, Jinyu, Pei, Jiang, Zhang, Qiangfeng, Song, Xingfa, Sun, Zengxian·2016·Journal of Chromatography B

Abstract

In this study, a simple and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for quantitation of droxidopa in human plasma for the first time. A simple plasma protein precipitation method using methanol containing 3% formic acid was selected, and the separation was achieved by an Acquity UPLC™ BEH Amide column (2.1mm×50mm, 1.7μm) with a gradient elution using acetonitrile, ammonium formate buffer and formic acid as mobile phase. The detection of droxidopa and benserazide (internal standard, IS) was performed using positive-ion electrospray tandem mass spectrometry via multiple reaction monitoring (MRM). The precursor-to-product ion transitions m/z 214.2→m/z 152.0 for droxidopa, and m/z 258.1→m/z 139.1 for IS were used for quantification. A lower limit of quantification of 5.00ng/mL was achieved and the linear curve range was 5.00-4000ng/mL using a weighted (1/x(2)) linear regression model. Intra-assay and inter-assay precision was less than 10.2%, and the accuracy ranged from 0.1% to 2.1%. Stability, recovery and matrix effects were within the acceptance criteria recommended by the regulatory bioanalytical guidelines. The method was successfully applied to a pharmacokinetic study of droxidopa in healthy Chinese volunteers.

Integrity signals

Registry

Crossref · 10.1016/j.jchromb.2016.04.056

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Droxidopa is an orally active, synthetic prodrug of norepinephrine that reaches peak plasma concentration in 2 h.

    “Droxidopa is an orally active, synthetic prodrug of norepinephrine that reaches peak plasma concentration in 2 h (57).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wang, H., Yang, G., Zhou, J., Pei, J., Zhang, Q., Song, X., & Sun, Z.
Affiliations
  • The First People’s Hospital of Lianyungang (CN)
  • Jining First People's Hospital (CN)
Corresponding author
Sun, Zengxian
Venue
Journal of Chromatography B
Publisher
Elsevier BV
Published
2016-08
Volume
1027
Pages
234-238
ISSN
1570-0232 (ISSN-L)
OpenAlex
W2358651311
Cited by
12
References
19
Citations by year
2026: 1 · 2025: 1 · 2023: 3 · 2021: 1 · 2019: 3 · 2018: 1 · 2017: 2
FWCI
1.58
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography B (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
Keywords
droxidopa, UPLC-MS/MS, plasma quantitation, bioanalytical method validation, pharmacokinetics, plasma protein precipitation, multiple reaction monitoring, healthy volunteers
MeSH terms
Adult, Animals, Antiparkinson Agents, Chromatography, High Pressure Liquid, Humans, Male, Droxidopa, Reproducibility of Results, Tandem Mass Spectrometry, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review