Zhang, Haifeng, Quan, Li, Pei, Pei, Lin, Ye, Feng, Chao, Guan, Hongyan, Wang, Fang, Zhang, Ting +2 more·2018·Journal of Chromatography B

Abstract

A sensitive method for the simultaneous analysis of vitamin A (VA), 25-hydroxyl vitamin D 3 (25-OH VD 3 ) and α-tocopherol (VE) in children plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated. Sample preparation chose the solid phase extraction. 100 μL of plasma was mixed with 300 μL ethanol contained 4 μL isotope-labelled analytes. After a series operation, the supernatant was applied to the solid phase extraction (SPE) plate (HLB μElution plate). The eluate was evaporated, and reconstituted in 100 μL methanol. And then, 6 μL reconstituted sample was injected into LC-MS/MS. Quantitative analysis was carried out by multiple reaction monitoring (MRM) with a positive mode electrospray (ESi + ). Separations of VA, 25-OH VD 3 and VE were performed on an Acquity UPLC reversed-phase Phenyl-Hexyl analytical column (CSH, 2.1 × 50 mm, 1.7 μm). Gradient elution was used at a flow rate of 0.4 mL/min with a mobile phase consisting of 0.1% formic acid solution and 0.1% formic acid, 5 mM ammonium formate in acetonitrile. The total time of analysis was 10 min. The method had a limit of quantification (LOQ) of 10.03, 1.20, and 0.04 ng/mL for VA, 25-OH VD 3 and VE in methanol, respectively. The linear calibration curves were fitted over the range of 0.14-14.32 μg/mL, 1.80-180.29 ng/mL, and 6.03-602.99 ng/mL for VA, 25-OH VD 3 and VE in methanol. The correlation coefficients were greater than 0.998 for all analytes. The recoveries for all analyt…

Integrity signals

Registry

Crossref · 10.1016/j.jchromb.2017.12.017

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • MS/MS is currently the most sensitive method used for making bioanalyses of retinoic acid and is readily coupled with LC separations capable of resolving isomers of retinoic acid.

    “MS/MS is currently the most sensitive method used for making bioanalyses of retinoic acid and is readily coupled with LC separations capable of resolving isomers of retinoic acid.”
  • MS/MS offers appropriate sensitivity for the detection through background reductions of 100-1000-fold over MS.

    “MS/MS offers appropriate sensitivity for the detection through background reductions of 100–1000-fold over MS.”
  • GC-MS allows for good sensitivity but requires additional derivatization steps for making retinoid acid analyses, often representing labor-intensive procedures and a potential source of errors.

    “GC–MS allows for good sensitivity but requires additional derivatization steps for making retinoid acid analyses, often representing labor-intensive procedures and a potential source of errors.”
  • Triple-quadrupole LC-MS/MS facilitates the most effective qualitative-quantitative analysis of retinoic acid with sufficient sensitivity and specificity, yet no requirement for derivatization or definite mass identification.

    “Triple-quadrupole LC–MS/MS facilitates the most effective qualitative–quantitative analysis of retinoic acid with sufficient sensitivity and specificity, yet no requirement for derivatization or definite mass identification.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhang, H., Quan, L., Pei, P., Lin, Y., Feng, C., Guan, H., Wang, F., Zhang, T., Wu, J., & Huo, J.
Affiliations
  • Capital Institute of Pediatrics (CN)
  • Chinese Academy of Medical Sciences & Peking Union Medical College (CN)
  • Chinese Center For Disease Control and Prevention (CN)
Corresponding author
Wu, Jianxin
Venue
Journal of Chromatography B
Publisher
Elsevier BV
Published
2018-03
Volume
1079
Pages
1-8
ISSN
1570-0232 (ISSN-L)
OpenAlex
W2773462249
Cited by
29
References
2
Citations by year
2026: 2 · 2025: 3 · 2024: 2 · 2023: 4 · 2022: 4 · 2021: 4 · 2020: 8 · 2018: 2
FWCI
1.91
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Chromatography B (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • National Natural Science Foundation of China (81501838)
  • Beijing Talents Fund (2014000021469G229)
  • Contract Grant Sponsors: Chinese National “973” Program on Population and Health (2013CB945404)
  • CAMS Initiative for Innovative Medicine (2016-I2M-1-008)
  • Research of Beijing Medical (2016-4)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Physical Sciences › Chemistry › Spectroscopy › Analytical Chemistry and Chromatography
  • Health Sciences › Medicine › Biochemistry › Antioxidant Activity and Oxidative Stress
Keywords
vitamin A, 25-hydroxyvitamin D3, alpha-tocopherol, vitamin E, plasma, children, simultaneous determination, solid-phase extraction, isotope-labeled internal standards, vitamin status
MeSH terms
Calibration, Child, Cholecalciferol, Chromatography, High Pressure Liquid, Humans, Vitamin A, alpha-Tocopherol, Solid Phase Extraction, Tandem Mass Spectrometry, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review