Determination of three tetracyclines in bovine milk using magnetic solid phase extraction in tandem with dispersive liquid-liquid microextraction coupled with HPLC
The DOI matches its Crossref record.
Abstract
A novel analytical method namely magnetic solid phase extraction in tandem with dispersive liquid-liquid microextraction was developed and used for the extraction/preconcentration of tetracycline (TCN), oxytetracycline (OTC) and doxycycline (DC) from bovine milk sample before HPLC-UV analysis. The β-cyclodextrin functionalized silica-coated magnetic graphene oxide (Fe3O4@SiO2@GO-β-CD) was used as an adsorbent. The adsorbent was fully characterized using FT-IR, SEM, EDX and Zeta potential techniques. The effective parameters on the performance of the method such as extraction solvent type and volume, adsorbent amount, desorption solvent type and volume, disperser solvent type, desorption time, ionic strength and pH value were investigated. The limit of detection (LOD) and limit of quantification (LOQ) were obtained in the ranges of 1.8-2.9 μg L-1 and 6.1-9.7 μg L-1, respectively. The linearity was in the range of 10.0-200.0 μg L-1 with satisfactory determination coefficients (R2) higher than 0.9929 and a good precision (RSD < 8.8%). The recovery percentages for the analytes in real samples (bovine milk and water) were achieved in a range from 70.6 to 121.5%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Alipanahpour Dil, E., Ghaedi, M., Asfaram, A., Tayebi, L., & Mehrabi, F. (2020) · Journal of Chromatography A · doi:10.1016/j.chroma.2019.460695 · Cited by 134
Recent advances and applications of graphene-based extraction materials in food safety
Hou, X., Tang, S., & Wang, J. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.07.014 · Cited by 77
Development and challenges of supramolecular solvents in liquid-based microextraction methods
Moradi, M., Yamini, Y., & Feizi, N. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116231 · Cited by 74
Jano, A., Fuente-Ballesteros, A., Ares, A. M., & Bernal, J. (2025) · Microchemical Journal · doi:10.1016/j.microc.2025.113794 · Cited by 48
Sereshti, H., Jamshidi, F., Nouri, N., & Nodeh, H. R. (2020) · Journal of the Science of Food and Agriculture · doi:10.1002/jsfa.10279 · Cited by 38
Self-citation
Metadata
- Authors
- Al-Afy, N., Sereshti, H., Hijazi, A., & Rashidi Nodeh, H.
- Venue
- Journal of Chromatography B
- Publisher
- Elsevier BV
- Published
- 2018-08
- Volume
- 1092
- Pages
- 480-488
- ISSN
- 1570-0232 (ISSN-L)
- OpenAlex
- W2810985174
- Cited by
- 107
- References
- 0
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of three tetracyclines in bovine milk using magnetic solid phase extraction in tandem with dispersive liquid-liquid microextraction coupled with HPLC. https://app.cochat.ai/papers/10.1016/j.jchromb.2018.06.049
- The paper
- Al-Afy, N., Sereshti, H., Hijazi, A., & Rashidi Nodeh, H. (2018). Determination of three tetracyclines in bovine milk using magnetic solid phase extraction in tandem with dispersive liquid-liquid microextraction coupled with HPLC. Journal of Chromatography B. https://doi.org/10.1016/j.jchromb.2018.06.049
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.