Formulation of Nanoparticle-Eluting Stents by a Cationic Electrodeposition Coating Technology
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVES The objective of this study was to formulate a nanoparticle (NP)-eluting drug delivery stent system by a cationic electrodeposition coating technology. BACKGROUND Nanoparticle-mediated drug delivery systems (DDS) are poised to transform the development of innovative therapeutic devices. Therefore, we hypothesized that a bioabsorbable polymeric NP-eluting stent provides an efficient DDS that shows better and more prolonged delivery compared with dip-coating stent. METHODS We prepared cationic NP encapsulated with a fluorescence marker (FITC) by emulsion solvent diffusion method, succeeded to formulate an NP-eluting stent with a novel cation electrodeposition coating technology, and compared the in vitro and in vivo characteristics of the FITC-loaded NP-eluting stent with dip-coated FITC-eluting stent and bare metal stent. RESULTS The NP was taken up stably and efficiently by cultured vascular smooth muscle cells in vitro. In a porcine coronary artery model in vivo, substantial FITC fluorescence was observed in neointimal and medial layers of the stented segments that had received the FITC-NP-eluting stent until 4 weeks. In contrast, no substantial FITC fluorescence was observed in the segments from the polymer-based FITC-eluting stent or from bare metal stent. The magnitudes of stent-induced injury, inflammation, endothelial recovery, and neointima formation were comparable between bare metal stent and NP-eluting stent groups. CONCLUSIONS Therefore, this NP-eluting stent is an efficient NP-mediated DDS that holds as an innovative platform for the delivery of less invasive nano-devices targeting cardiovascular disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Cited by
Sahu, T., Ratre, Y. K., Chauhan, S., Bhaskar, L. V. K. S., Nair, M. P., & Verma, H. K. (2021) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2021.102487 · Cited by 487
Perspectives and opportunities for nanomedicine in the management of atherosclerosis
Lobatto, M. E., Fuster, V., Fayad, Z. A., & Mulder, W. J. M. (2011) · Nature Reviews Drug Discovery · doi:10.1038/nrd3578 · Cited by 423
Nanoscale surface modifications of medically relevant metals: state-of-the art and perspectives
Variola, F., Brunski, J. B., Orsini, G., Tambasco de Oliveira, P., Wazen, R., & Nanci, A. (2011) · Nanoscale · doi:10.1039/c0nr00485e · Cited by 260
Application of the Nano-Drug Delivery System in Treatment of Cardiovascular Diseases
Deng, Y., Zhang, X., Shen, H., He, Q., Wu, Z., Liao, W., & Yuan, M. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00489 · Cited by 259
Adipurnama, I., Yang, M.-C., Ciach, T., & Butruk-Raszeja, B. (2017) · Biomaterials Science · doi:10.1039/c6bm00618c · Cited by 179
Metadata
- Authors
- Nakano, K., Egashira, K., Masuda, S., Funakoshi, K., Zhao, G., Kimura, S., Matoba, T., Sueishi, K., Endo, Y., Kawashima, Y., Hara, K., Tsujimoto, H., Tominaga, R., & Sunagawa, K.
- Venue
- JACC: Cardiovascular Interventions
- Publisher
- Elsevier BV
- Published
- 2009-04
- Volume
- 2
- Issue
- 4
- Pages
- 277-283
- ISSN
- 1876-7605 (ISSN-L)
- 1936-8798
- OpenAlex
- W128958689
- Cited by
- 139
- References
- 1
- FWCI
- 8.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Formulation of Nanoparticle-Eluting Stents by a Cationic Electrodeposition Coating Technology. https://app.cochat.ai/papers/10.1016/j.jcin.2008.08.023
- The paper
- Nakano, K., Egashira, K., Masuda, S., Funakoshi, K., Zhao, G., Kimura, S., Matoba, T., Sueishi, K., Endo, Y., Kawashima, Y., Hara, K., Tsujimoto, H., Tominaga, R., & Sunagawa, K. (2009). Formulation of Nanoparticle-Eluting Stents by a Cationic Electrodeposition Coating Technology. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2008.08.023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.