Cited by 179Polymer Surface Interaction StudiesTissue Engineering and Regenerative Medicinebiodegradable polymer synthesis and properties

Surface modification and endothelialization of polyurethane for vascular tissue engineering applications: a review

Adipurnama, Iman, Yang, Ming-Chien, Ciach, Tomasz, Butruk-Raszeja, Beata·2017·Biomaterials Science

Abstract

This review summarizes the surface modification and endothelialization of polyurethane for vascular tissue engineering applications, including recent developments and strategies.

Integrity signals

Registry

Crossref · 10.1039/c6bm00618c

Cites

123 of 123 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Other agents including fucoidan, laminin, hyaluronic acid, chondroitin sulfate, type 1 collagen, and VEGF have been used to improve endothelialization on the surface of nano and metal stents and thin tissues such as heart valve and blood vessels.

    “Other agents, including fucoidan (FU), laminin, hyaluronic acid (HA), chondroitin sulfate, type 1 collagen, and vascular endothelial growth factor (VEGF), have been used to improve endothelialization on the surface of nano and metal stents as well as thin tissues such as heart valve and blood vessels [231,234].”
  • EPCs are circulating cells in peripheral blood originating from the bone marrow, representing approximately 0.01% of all blood mononuclear cells, with some cells residing in adipose tissue of adults.

    “Endothelial progenitor cells (EPCs) are circulating cells in peripheral blood originating from the bone marrow, representing approximately 0.01 % of all blood mononuclear cells, with some cells residing in the adipose tissue of adults [234].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Adipurnama, I., Yang, M.-C., Ciach, T., & Butruk-Raszeja, B.
Affiliations
  • National Taiwan University of Science and Technology (TW)
  • Warsaw University of Technology (PL)
Corresponding author
Yang, Ming-Chien
Venue
Biomaterials Science
Published
2017
Volume
5
Issue
1
Pages
22-37
ISSN
  • 2047-4830 (ISSN-L)
  • 2047-4849
OpenAlex
W2562475264
Cited by
179
References
123
Citations by year
2026: 11 · 2025: 17 · 2024: 15 · 2023: 19 · 2022: 23 · 2021: 19 · 2020: 27 · 2019: 20 · 2018: 16 · 2017: 12
FWCI
0.90
Type
journal article
Language
en
Open access
closed
Locations
  • Biomaterials Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
U.S. Food and Drug Administration
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
Keywords
polyurethane, vascular grafts, endothelialization, surface modification, hemocompatibility, restenosis, thrombus formation, polyethylene glycol, zwitterion, polysaccharides, peptide coating, biomolecules, gene delivery, bioactive polymers, graft patency
MeSH terms
Blood Vessel Prosthesis, Cell Adhesion, Humans, Polyurethanes, Thrombosis, Tissue Engineering, Endothelial Cells

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review