Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 484

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Real-Time Ultrasound Guidance Facilitates Femoral Arterial Access and Reduces Vascular Complications

Open access
Seto, Arnold H., Abu-Fadel, Mazen S., Sparling, Jeffrey M., Zacharias, Soni J., Daly, Timothy S., Harrison, Alexander T., Suh, William M., Vera, Jesus A., Aston, Christopher E., Winters, Rex J., Patel, Pranav M., Hennebry, Thomas A., Kern, Morton J.·2010·JACC: Cardiovascular Interventions

Abstract

OBJECTIVES The aim of this study was to compare the procedural and clinical outcomes of femoral arterial access with ultrasound (US) guidance with standard fluoroscopic guidance. BACKGROUND Real-time US guidance reduces time to access, number of attempts, and complications in central venous access but has not been adequately assessed in femoral artery cannulation. METHODS Patients (n = 1,004) undergoing retrograde femoral arterial access were randomized 1:1 to either fluoroscopic or US guidance. The primary end point was successful common femoral artery (CFA) cannulation by femoral angiography. Secondary end points included time to sheath insertion, number of forward needle advancements, first pass success, accidental venipunctures, and vascular access complications at 30 days. RESULTS Compared with fluoroscopic guidance, US guidance produced no difference in CFA cannulation rates (86.4% vs. 83.3%, p = 0.17), except in the subgroup of patients with CFA bifurcations occurring over the femoral head (82.6% vs. 69.8%, p < 0.01). US guidance resulted in an improved first-pass success rate (83% vs. 46%, p < 0.0001), reduced number of attempts (1.3 vs. 3.0, p < 0.0001), reduced risk of venipuncture (2.4% vs. 15.8%, p < 0.0001), and reduced median time to access (136 s vs. 148 s, p = 0.003). Vascular complications occurred in 7 of 503 and 17 of 501 in the US and fluoroscopy groups, respectively (1.4% vs. 3.4% p = 0.04). CONCLUSIONS In this multicenter randomized controlled trial, routine real-time US guidance improved CFA cannulation only in patients with high CFA bifurcations but reduced the number of attempts, time to access, risk of venipunctures, and vascular complications in femoral arterial access. (Femoral Arterial Access With Ultrasound Trial [FAUST]; NCT00667381).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcin.2010.04.015

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 484

Metadata

Authors
Seto, A. H., Abu-Fadel, M. S., Sparling, J. M., Zacharias, S. J., Daly, T. S., Harrison, A. T., Suh, W. M., Vera, J. A., Aston, C. E., Winters, R. J., Patel, P. M., Hennebry, T. A., & Kern, M. J.
Venue
JACC: Cardiovascular Interventions
Publisher
Elsevier BV
Published
2010-07
Volume
3
Issue
7
Pages
751-758
ISSN
  • 1876-7605 (ISSN-L)
  • 1936-8798
OpenAlex
W23110405
Cited by
484
References
12
FWCI
12.05
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-Time Ultrasound Guidance Facilitates Femoral Arterial Access and Reduces Vascular Complications. https://app.cochat.ai/papers/10.1016/j.jcin.2010.04.015
The paper
Seto, A. H., Abu-Fadel, M. S., Sparling, J. M., Zacharias, S. J., Daly, T. S., Harrison, A. T., Suh, W. M., Vera, J. A., Aston, C. E., Winters, R. J., Patel, P. M., Hennebry, T. A., & Kern, M. J. (2010). Real-Time Ultrasound Guidance Facilitates Femoral Arterial Access and Reduces Vascular Complications. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2010.04.015

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.