Feasibility of Transcatheter Aortic Valve Implantation Without Balloon Pre-Dilation

Open access
Grube, Eberhard, Naber, Christoph, Abizaid, Alexandre, Sousa, Eduardo, Mendiz, Oscar, Lemos, Pedro, Kalil Filho, Roberto, Mangione, Jose, Buellesfeld, Lutz·2011·JACC: Cardiovascular Interventions

Abstract

OBJECTIVES The purpose of this pilot study was to evaluate the feasibility and safety of transcatheter aortic valve implantation (TAVI) without balloon pre-dilation. BACKGROUND Balloon pre-dilation of the stenosed aortic valve is currently believed to be a necessary step for valve preparation before device placement in patients undergoing TAVI and, therefore, is considered an obligatory part of the procedure. However, clear evidence supporting this policy is lacking. In contrast, pre-dilation might be responsible in part for distal embolizations as well as atrioventricular conduction disturbances seen during TAVI procedures. METHODS A total of 60 consecutive patients (mean age 80.1 ± 6.4 years, 53% female, mean logistic EuroScore 23.3 ± 15.2%) undergoing TAVI using the self-expanding Medtronic CoreValve prosthesis (Medtronic, Minneapolis, Minnesota) have been prospectively enrolled at 13 international centers. RESULTS Pre-procedural mean transaortic valve gradient was 47.8 ± 15.5 mm Hg, mean effective orifice area was 0.67 ± 0.15 cm(2). Technical success rate was 96.7% (58 of 60) of patients. Post-dilation was performed in 16.7% (10 of 60) of patients. Post-procedural mean valve gradient was 4.4 ± 2.0 mm Hg. Circular and noncircular valve configuration was present in 41 and 19 cases (68.3% vs. 31.7%), respectively, with similar effective orifice areas (1.74 ± 0.10 cm(2) vs. 1.71 ± 0.22 cm(2), p = NS). In-hospital mortality, myocardial infarction, stroke, and major vascular complications occurred in 6.7% (4 of 60), 0%, 5%, and 10% of patients. There was no valve embolization. New permanent pacing was needed in 11.7% (7 of 60) of patients. CONCLUSIONS Transcatheter aortic valve implantation without balloon pre-dilation is feasible and safe, resulting in similar acute safety and efficacy as the current standard approach of TAVI with pre-dilation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcin.2011.03.015

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 182

Metadata

Authors
Grube, E., Naber, C., Abizaid, A., Sousa, E., Mendiz, O., Lemos, P., Kalil Filho, R., Mangione, J., & Buellesfeld, L.
Venue
JACC: Cardiovascular Interventions
Publisher
Elsevier BV
Published
2011-07
Volume
4
Issue
7
Pages
751-757
ISSN
  • 1876-7605 (ISSN-L)
  • 1936-8798
OpenAlex
W188620840
Cited by
182
References
2
FWCI
19.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.