CoChat

Five-Year Clinical and Functional Multislice Computed Tomography Angiographic Results After Coronary Implantation of the Fully Resorbable Polymeric Everolimus-Eluting Scaffold in Patients With De Novo Coronary Artery Disease

Open access
Onuma, Yoshinobu, Dudek, Dariusz, Thuesen, Leif, Webster, Mark, Nieman, Koen, Garcia-Garcia, Hector M., Ormiston, John A., Serruys, Patrick W. · 2013 · JACC: Cardiovascular Interventions
Cited by 215

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVES This study sought to demonstrate the 5-year clinical and functional multislice computed tomography angiographic results after implantation of the fully resorbable everolimus-eluting scaffold (Absorb BVS, Abbott Vascular, Santa Clara, California). BACKGROUND Multimodality imaging of the first-in-humans trial using a ABSORB BVS scaffold demonstrated at 2 years the bioresorption of the device while preventing restenosis. However, the long-term safety and efficacy of this therapy remain to be documented. METHODS In the ABSORB cohort A trial (ABSORB Clinical Investigation, Cohort A [ABSORB A] Everolimus-Eluting Coronary Stent System Clinical Investigation), 30 patients with a single de novo coronary artery lesion were treated with the fully resorbable everolimus-eluting Absorb scaffold at 4 centers. As an optional investigation in 3 of the 4 centers, the patients underwent multislice computed tomography (MSCT) angiography at 18 months and 5 years. Acquired MSCT data were analyzed at an independent core laboratory (Cardialysis, Rotterdam, the Netherlands) for quantitative analysis of lumen dimensions and was further processed for calculation of fractional flow reserve (FFR) at another independent core laboratory (Heart Flow, Redwood City, California). RESULTS Five-year clinical follow-up is available for 29 patients. One patient withdrew consent after 6 months, but the vital status of this patient remains available. At 46 days, 1 patient experienced a single episode of chest pain and underwent a target lesion revascularization with a slight troponin increase after the procedure. At 5 years, the ischemia-driven major adverse cardiac event rate of 3.4% remained unchanged. Clopidogrel was discontinued in all but 1 patient. Scaffold thrombosis was not observed in any patient. Two noncardiac deaths were reported, 1 caused by duodenal perforation and the other from Hodgkin's disease. At 5 years, 18 patients underwent MSCT angiography. All scaffolds were patent, with a median minimal lumen area of 3.25 mm(2) (interquartile range: 2.20 to 4.30). Noninvasive FFR analysis was feasible in 13 of 18 scans, which yielded a median distal FFR of 0.86 (interquartile range: 0.82 to 0.94). CONCLUSIONS The low event rate at 5 years suggests sustained safety after the implantation of a fully bioresorbable Absorb everolimus-eluting scaffold. Noninvasive assessment of the coronary artery with an option of functional assessment could be an alternative to invasive imaging after treatment of coronary narrowing with such a polymeric bioresorbable scaffold. (ABSORB Clinical Investigation, Cohort A [ABSORB A] Everolimus-Eluting Coronary Stent System Clinical Investigation [ABSORB]; NCT00300131).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcin.2013.05.017

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Onuma, Y., Dudek, D., Thuesen, L., Webster, M., Nieman, K., Garcia-Garcia, H. M., Ormiston, J. A., & Serruys, P. W.
Venue
JACC: Cardiovascular Interventions
Publisher
Elsevier BV
Published
2013-10
Volume
6
Issue
10
Pages
999-1009
ISSN
  • 1876-7605 (ISSN-L)
  • 1936-8798
OpenAlex
W1738689443
Cited by
215
References
2
FWCI
34.13
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.