Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 166

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve Implantation

Open access
De Torres-Alba, Fernando, Kaleschke, Gerrit, Diller, Gerhard Paul, Vormbrock, Julia, Orwat, Stefan, Radke, Robert, Reinke, Florian, Fischer, Dieter, Reinecke, Holger, Baumgartner, Helmut · 2016 · JACC: Cardiovascular Interventions

Abstract

OBJECTIVES: The aim of this study was to analyze the pacemaker implantation rate (PMIR) with the new balloon-expandable Edwards SAPIEN 3 valve (S3) and the factors associated with it. BACKGROUND: The introduction of the S3 for transcatheter aortic valve replacement (TAVR) has led to a reduction in paravalvular regurgitation. There are, however, concerns that the new design may increase the PMIR. METHODS: The first 206 patients treated with the S3 were compared with 371 preceding patients treated with SAPIEN XT valves. Patients who previously underwent pacemaker or implantable cardioverter defibrillator implantation or transapical and valve-in-valve procedures were excluded from the analysis. All patients were monitored for at least 7 days. Previous and new conduction abnormalities were documented, and prosthesis implantation height was assessed for the S3. RESULTS: There were no significant differences in baseline characteristics between groups. The PMIR was, however, significantly higher for the S3 (19.1% vs. 12.2%; p = 0.046). The mean implantation height was significantly lower in patients requiring PMI (67%/33% vs. 72%/28% aortic/ventricular stent extension, p = 0.032). On multivariate regression analysis, implantation height was the only independent predictor of PMI (odds ratio: 0.94 [95% confidence interval: 0.90 to 0.99]; p = 0.009). It increased from 68%/32% to 75%/25% when comparing the first with the second half of S3 implantations (p < 0.0001). This change was associated with a significant decrease in PMIR from 25.9% to 12.3% (p = 0.028), no longer different from the XT valve (12.2%). CONCLUSIONS: The PMIR after TAVR is higher with the S3 than with the XT and is independently associated with the implantation height. This increase in the PMIR may be avoided by intending an aortic stent extension >70%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcin.2015.12.023

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 166

Metadata

Authors
De Torres-Alba, F., Kaleschke, G., Diller, G. P., Vormbrock, J., Orwat, S., Radke, R., Reinke, F., Fischer, D., Reinecke, H., & Baumgartner, H.
Venue
JACC: Cardiovascular Interventions
Publisher
Elsevier BV
Published
2016-04
Volume
9
Issue
8
Pages
805-813
ISSN
  • 1876-7605 (ISSN-L)
  • 1936-8798
OpenAlex
W2308734203
Cited by
166
References
3
FWCI
19.67
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve Implantation. https://app.cochat.ai/papers/10.1016/j.jcin.2015.12.023
The paper
De Torres-Alba, F., Kaleschke, G., Diller, G. P., Vormbrock, J., Orwat, S., Radke, R., Reinke, F., Fischer, D., Reinecke, H., & Baumgartner, H. (2016). Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve Implantation. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2015.12.023

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.