Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 550

The DOI matches its Crossref record; 163 of the 163 references it cites were found in a registry or an index.

Conduction Disturbances After Transcatheter Aortic Valve Replacement: Current Status and Future Perspectives

Auffret, Vincent, Puri, Rishi, Urena, Marina, Chamandi, Chekrallah, Rodriguez-Gabella, Tania, Philippon, François, Rodés-Cabau, Josep·2017·Circulation

Abstract

Transcatheter aortic valve replacement (TAVR) has become a well-accepted option for treating patients with aortic stenosis at intermediate to high or prohibitive surgical risk. TAVR-related conduction disturbances, mainly new-onset left bundle-branch block and advanced atrioventricular block requiring permanent pacemaker implantation, remain the most common complication of this procedure. Furthermore, improvements in TAVR technology, akin to the increasing experience of operators/centers, have translated to a major reduction in periprocedural complications, yet the incidence of conduction disturbances has remained relatively high, with perhaps an increasing trend over time. Several factors have been associated with a heightened risk of conduction disturbances and permanent pacemaker implantation after TAVR, with prior right bundle-branch block and transcatheter valve type and implantation depth being the most commonly reported. New-onset left bundle-branch block and the need for permanent pacemaker implantation may have a significant detrimental association with patients’ prognosis. Consequently, strategies intended to reduce the risk and to improve the management of such complications are of paramount importance, particularly in an era when TAVR expansion toward treating lower-risk patients is considered inevitable. In this article, we review the available evidence on the incidence, predictive factors, and clinical association of conduction disturbances after TAVR and propose a strategy for the management of these complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.117.028352

Cites

163 of 163 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 163 references

Cited by

See all 550

Metadata

Authors
Auffret, V., Puri, R., Urena, M., Chamandi, C., Rodriguez-Gabella, T., Philippon, F., & Rodés-Cabau, J.
Venue
Circulation
Published
2017-09-12
Volume
136
Issue
11
Pages
1049-1069
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2754083347
Cited by
550
References
163
FWCI
30.99
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Conduction Disturbances After Transcatheter Aortic Valve Replacement: Current Status and Future Perspectives. https://app.cochat.ai/papers/10.1161/circulationaha.117.028352
The paper
Auffret, V., Puri, R., Urena, M., Chamandi, C., Rodriguez-Gabella, T., Philippon, F., & Rodés-Cabau, J. (2017). Conduction Disturbances After Transcatheter Aortic Valve Replacement: Current Status and Future Perspectives. Circulation. https://doi.org/10.1161/circulationaha.117.028352

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.