CoChat

Association Between Cardiac Catheterization Laboratory Pre-Activation and Reperfusion Timing Metrics and Outcomes in Patients With ST-Segment Elevation Myocardial Infarction Undergoing Primary Percutaneous Coronary Intervention

Open access
Shavadia, Jay S., Roe, Matthew T., Chen, Anita Y., Lucas, Joseph, Fanaroff, Alexander C., Kochar, Ajar, Fordyce, Christopher B., Jollis, James G., Tamis-Holland, Jacqueline, Henry, Timothy D., Bagai, Akshay, Kontos, Michael C., Granger, Christopher B., Wang, Tracy Y. · 2018 · JACC: Cardiovascular Interventions
Cited by 45

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVES The aim of this study was to describe the prevalence of pre-hospital cardiac catheterization laboratory activation and its association with reperfusion timeliness and in-hospital mortality. BACKGROUND For patients with ST-segment elevation myocardial infarction diagnosed in the field, catheterization laboratory pre-activation may lead to more timely reperfusion and improved outcomes. METHODS A total of 27,840 patients with ST-segment elevation myocardial infarction transported via emergency medical services to 744 percutaneous coronary intervention-capable hospitals in the ACTION Registry from January 2015 to March 2017 were evaluated, excluding patients with cardiac arrest or requiring pre-percutaneous coronary intervention intubation. Catheterization laboratory pre-activation was defined as activation >10 min prior to hospital arrival. RESULTS Catheterization laboratory pre-activation occurred in 41% of patients (n = 11,379), with minor presenting differences between those with and without catheterization laboratory pre-activation. Compared with no catheterization laboratory pre-activation, pre-activation patients were more likely to be directly transported to the catheterization laboratory on hospital arrival (23.3% vs. 5.3%), to have shorter hospital arrival-to-catheterization laboratory arrival time (median 17 min [interquartile range (IQR): 7 to 25 min] vs. 28 min [IQR: 18 to 39 min]), to have shorter door-to-device time (40 min [IQR: 30 to 51 min] vs. 52 min [IQR: 41 to 65 min]), and to have a greater likelihood of achieving first medical contact-to-device time ≤90 min (76.6% vs. 68.6%) (p < 0.001 for all). Pre-activation was associated with lower in-hospital mortality (2.8% vs. 3.4%; p = 0.01). Patients treated at hospitals in the lowest tertile of pre-activation rates had higher mortality than those treated at hospitals in the highest tertile before and after adjustment (3.6% vs. 2.7%; adjusted odds ratio: 1.33; 95% confidence interval: 1.08 to 1.63). CONCLUSIONS In the United States, catheterization laboratory pre-activation occurred in fewer than one-half of emergency medical services-transported patients with ST-segment elevation myocardial infarction. Its association with faster reperfusion and lower mortality supports greater use of this strategy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcin.2018.07.020

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 45

Metadata

Authors
Shavadia, J. S., Roe, M. T., Chen, A. Y., Lucas, J., Fanaroff, A. C., Kochar, A., Fordyce, C. B., Jollis, J. G., Tamis-Holland, J., Henry, T. D., Bagai, A., Kontos, M. C., Granger, C. B., & Wang, T. Y.
Venue
JACC: Cardiovascular Interventions
Publisher
Elsevier BV
Published
2018-09
Volume
11
Issue
18
Pages
1837-1847
ISSN
  • 1876-7605 (ISSN-L)
  • 1936-8798
OpenAlex
W2890619230
Cited by
45
References
1
FWCI
2.92
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.