The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Drug-Coated Balloons for Coronary Artery Disease
Open accessAbstract
Although drug-eluting stents are still the default interventional treatment of coronary artery disease, drug-coated balloons (DCBs) represent a novel alternative therapeutic strategy in certain anatomic conditions. The effect of DCBs is based on the fast and homogenous transfer of antiproliferative drugs into the vessel wall during single balloon inflation by means of a lipophilic matrix without the use of permanent implants. Although their use is established for in-stent restenosis of both bare-metal and drug-eluting stents, recent randomized clinical data demonstrate a good efficacy and safety profile in de novo small-vessel disease and high bleeding risk. In addition, there are other emerging indications (e.g., bifurcation lesions, large-vessel disease, diabetes mellitus, acute coronary syndromes). Because the interaction among the different delivery balloon designs, doses, formulations, and release kinetics of the drugs used is important, there seems to be no "class effect" of DCBs. On the basis of the amount of recently published data, the International DCB Consensus Group provides this update of previous recommendations summarizing the historical background, technical considerations such as choice of device and implantation technique, possible indications, and future perspectives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
Self-citationSerruys, P. W., de Jaegere, P., Kiemeneij, F., Macaya, C., Rutsch, W., Heyndrickx, G., Emanuelsson, H., Marco, J., Legrand, V., Materne, P., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199408253310801 · Cited by 4,556
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Schömig, A., Neumann, F.-J., Kastrati, A., Schühlen, H., Blasini, R., Hadamitzky, M., Walter, H., Zitzmann-Roth, E.-M., Richardt, G., Alt, E., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604253341702 · Cited by 2,028
Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987) · New England Journal of Medicine · doi:10.1056/nejm198703193161201 · Cited by 1,892
2018 ESC/EACTS Guidelines on myocardial revascularization
Neumann, F. J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2018) · Kardiologia Polska · doi:10.5603/kp.2018.0228 · Cited by 1,126
Self-citationHolmes, D. R., Vlietstra, R. E., Smith, H. C., Vetrovec, G. W., Kent, K. M., Cowley, M. J., Faxon, D. P., Gruentzig, A. R., Kelsey, S. F., Detre, K. M., et al. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90752-5 · Cited by 1,113
Katsanos, K., Spiliopoulos, S., Kitrou, P., Krokidis, M., & Karnabatidis, D. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.118.011245 · Cited by 1,020
Treatment of Coronary In-Stent Restenosis with a Paclitaxel-Coated Balloon Catheter
Scheller, B., Hehrlein, C., Bocksch, W., Rutsch, W., Haghi, D., Dietz, U., Böhm, M., & Speck, U. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061254 · Cited by 816
Self-citationByrne, R. A., Joner, M., & Kastrati, A. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv511 · Cited by 609
Metadata
- Authors
- Jeger, R. V., Eccleshall, S., Wan Ahmad, W. A., Ge, J., Poerner, T. C., Shin, E.-S., Alfonso, F., Latib, A., Ong, P. J., Rissanen, T. T., Saucedo, J., Scheller, B., & Kleber, F. X.
- Venue
- JACC: Cardiovascular Interventions
- Publisher
- Elsevier BV
- Published
- 2020-06
- Volume
- 13
- Issue
- 12
- Pages
- 1391-1402
- ISSN
- 1876-7605 (ISSN-L)
- 1936-8798
- OpenAlex
- W3031047464
- Cited by
- 600
- References
- 47
- FWCI
- 43.54
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Drug-Coated Balloons for Coronary Artery Disease. https://app.cochat.ai/papers/10.1016/j.jcin.2020.02.043
- The paper
- Jeger, R. V., Eccleshall, S., Wan Ahmad, W. A., Ge, J., Poerner, T. C., Shin, E.-S., Alfonso, F., Latib, A., Ong, P. J., Rissanen, T. T., Saucedo, J., Scheller, B., & Kleber, F. X. (2020). Drug-Coated Balloons for Coronary Artery Disease. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2020.02.043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.