Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty
Abstract
Occlusion and restenosis are the most common reasons that transluminal balloon angioplasty may fail to provide long-term benefit. An intravascular mechanical support was therefore developed with the aim of preventing restenosis and sudden closure of diseased arteries after angioplasty. The endoprosthesis consists of a self-expandable stainless-steel mesh that can be implanted nonsurgically in the coronary or peripheral arteries. Experiments in animals showed complete intimal coverage within weeks and no late thrombosis during a follow-up period of up to one year. We performed 10 implantations in 6 patients for iliac or femoral arterial disease; 24 coronary-artery stents were implanted in 19 patients who presented with coronary-artery restenoses (n = 17) or abrupt closure (n = 4) after transluminal angioplasty or deterioration of coronary-bypass grafts (n = 3). We observed three complications in the group with coronary disease. One thrombotic occlusion of a stent resulted in asymptomatic closure, a second acute thrombosis was managed successfully with thrombolysis, and one patient died after bypass surgery for a suspected but unfound occlusion. Follow-up in the patients has continued for nine months without evidence of any further restenoses within the stented segments. Our preliminary experience suggests that this vascular endoprosthesis may offer a useful way to prevent occlusion and restenosis after transluminal angioplasty. Long-term follow-up will be required to validate the early success of this procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Stent Thrombosis in the Modern Era: A Pooled Analysis of Multicenter Coronary Stent Clinical Trials
Cutlip, D. E., Baim, D. S., Ho, K. K. L., Popma, J. J., Lansky, A. J., Cohen, D. J., Carrozza, J. P., Chauhan, M. S., Rodriguez, O., & Kuntz, R. E. (2001) · Circulation · doi:10.1161/01.cir.103.15.1967 · Cited by 855
Yakacki, C. M., Shandas, R., Lanning, C., Rech, B., Eckstein, A., & Gall, K. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.030 · Cited by 618
The Road to Bioabsorbable Stents: Reaching Clinical Reality?
Erne, P., Schier, M., & Resink, T. J. (2006) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-004-0341-9 · Cited by 249
Kidane, A. G., Salacinski, H., Tiwari, A., Bruckdorfer, K. R., & Seifalian, A. M. (2004) · Biomacromolecules · doi:10.1021/bm0344553 · Cited by 166
Metadata
- Authors
- Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1987-03-19
- Volume
- 316
- Issue
- 12
- Pages
- 701-706
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2057330499
- Cited by
- 1,892
- References
- 0
- FWCI
- 67.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty. https://app.cochat.ai/papers/10.1056/nejm198703193161201
- The paper
- Sigwart, U., Puel, J., Mirkovitch, V., Joffre, F., & Kappenberger, L. (1987). Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal Angioplasty. New England Journal of Medicine. https://doi.org/10.1056/nejm198703193161201