Indigo Aspiration System for Treatment of Pulmonary Embolism
Open accessAbstract
OBJECTIVES The study sought to prospectively evaluate the safety and efficacy of the Indigo aspiration system in submassive acute pulmonary embolism (PE). BACKGROUND PE treatment with thrombolytics has bleeding risks. Aspiration thrombectomy can remove thrombus without thrombolytics, but data are lacking. METHODS This study was a prospective, single-arm, multicenter study that enrolled patients with symptomatic acute PE ≤14 days, systolic blood pressure ≥90 mm Hg, and right ventricular-to-left ventricular (RV/LV) ratio >0.9. The primary efficacy endpoint was change in RV/LV ratio from baseline to 48 h post-procedure on core lab-adjudicated computed tomography angiography. The primary safety endpoint was a composite of 48-h major adverse events: device-related death, major bleeding, and device-related serious adverse events (clinical deterioration, pulmonary vascular, or cardiac injury). All sites received Institutional Review Board approval. RESULTS A total of 119 patients (mean age 59.8 ± 15.0 years) were enrolled at 22 U.S. sites between November 2017 and March 2019. Median device insertion to removal time was 37.0 (interquartile range: 23.5 to 60.0) min. Two (1.7%) patients received intraprocedural thrombolytics. Mean RV/LV ratio reduction from baseline to 48 h post-procedure was 0.43 (95% confidence interval: 0.38 to 0.47; p < 0.0001). Two (1.7%) patients experienced 3 major adverse events. Rates of cardiac injury, pulmonary vascular injury, clinical deterioration, major bleeding, and device-related death at 48 h were 0%, 1.7%, 1.7%, 1.7%, and 0.8%, respectively. CONCLUSIONS In this multicenter prospective study the Indigo aspiration system was associated with a significant reduction in the RV/LV ratio and a low major adverse event rate in submassive PE patients. Intraprocedural thrombolytic drugs were avoided in 98.3% of patients. (Evaluating the Safety and Efficacy of the Indigo aspiration system in Acute Pulmonary Embolism [EXTRACT-PE]; NCT03218566).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz405 · Cited by 4,916
Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Torbicki, A., Perrier, A., Konstantinides, S., Agnelli, G., Galiè, N., Pruszczyk, P., Bengel, F., Brady, A. J. B., Ferreira, D., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn310 · Cited by 2,826
Jaff, M. R., McMurtry, M. S., Archer, S. L., Cushman, M., Goldenberg, N., Goldhaber, S. Z., Jenkins, J. S., Kline, J. A., Michaels, A. D., Thistlethwaite, P., et al. (2011) · Circulation · doi:10.1161/cir.0b013e318214914f · Cited by 2,229
Fibrinolysis for Patients with Intermediate-Risk Pulmonary Embolism
Meyer, G., Vicaut, E., Danays, T., Agnelli, G., Becattini, C., Beyer-Westendorf, J., Bluhmki, E., Bouvaist, H., Brenner, B., Couturaud, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1302097 · Cited by 1,706
2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Konstantinides, S., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M., Humbert, M., Kucher, N., et al. (2014) · Kardiologia Polska · doi:10.5603/kp.2014.0211 · Cited by 1,349
Kucher, N., Boekstegers, P., Müller, O. J., Kupatt, C., Beyer-Westendorf, J., Heitzer, T., Tebbe, U., Horstkotte, J., Müller, R., Blessing, E., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.005544 · Cited by 1,151
Piazza, G., Hohlfelder, B., Jaff, M. R., Ouriel, K., Engelhardt, T. C., Sterling, K. M., Jones, N. J., Gurley, J. C., Bhatheja, R., Kennedy, R. J., et al. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2015.04.020 · Cited by 943
Chatterjee, S., Chakraborty, A., Weinberg, I., Kadakia, M., Wilensky, R. L., Sardar, P., Kumbhani, D. J., Mukherjee, D., Jaff, M. R., & Giri, J. (2014) · JAMA · doi:10.1001/jama.2014.5990 · Cited by 818
Systemic thrombolytic therapy for acute pulmonary embolism: a systematic review and meta-analysis
Marti, C., John, G., Konstantinides, S., Combescure, C., Sanchez, O., Lankeit, M., Meyer, G., & Perrier, A. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehu218 · Cited by 605
Tu, T., Toma, C., Tapson, V. F., Adams, C., Jaber, W. A., Silver, M., Khandhar, S., Amin, R., Weinberg, M., Engelhardt, T., et al. (2019) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.12.022 · Cited by 571
Self-citation
Metadata
- Authors
- Sista, A. K., Horowitz, J. M., Tapson, V. F., Rosenberg, M., Elder, M. D., Schiro, B. J., Dohad, S., Amoroso, N. E., Dexter, D. J., Loh, C. T., Leung, D. A., Bieneman, B. K., Perkowski, P. E., Chuang, M. L., & Benenati, J. F.
- Venue
- JACC: Cardiovascular Interventions
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 14
- Issue
- 3
- Pages
- 319-329
- ISSN
- 1876-7605 (ISSN-L)
- 1936-8798
- OpenAlex
- W3121030539
- Cited by
- 351
- References
- 17
- FWCI
- 38.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Indigo Aspiration System for Treatment of Pulmonary Embolism. https://app.cochat.ai/papers/10.1016/j.jcin.2020.09.053
- The paper
- Sista, A. K., Horowitz, J. M., Tapson, V. F., Rosenberg, M., Elder, M. D., Schiro, B. J., Dohad, S., Amoroso, N. E., Dexter, D. J., Loh, C. T., Leung, D. A., Bieneman, B. K., Perkowski, P. E., Chuang, M. L., & Benenati, J. F. (2021). Indigo Aspiration System for Treatment of Pulmonary Embolism. JACC: Cardiovascular Interventions. https://doi.org/10.1016/j.jcin.2020.09.053
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.