The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Cadmium removal from single- and multi-metal () solutions by sorption on hydroxyapatite
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kinetics of Adsorption on Carbon from Solution
Weber, W. J., & Morris, J. C. (1963) · Journal of the Sanitary Engineering Division · doi:10.1061/jsedai.0000430 · Cited by 9,844
ENCYCLOPEDIA OF Surface and Colloid Science
Somasundaran, P., & Hubbard, A. T. (2021) · CRC Press eBooks · doi:10.1201/9780367813437 · Cited by 2,104
Remediation technologies for metal-contaminated soils and groundwater: An evaluation
Mulligan, C. N., Yong, R. N., & Gibbs, B. F. (2001) · Engineering Geology · doi:10.1016/s0013-7952(00)00101-0 · Cited by 1,521
Mohan, D., & Singh, K. P. (2002) · Water Research · doi:10.1016/s0043-1354(01)00447-x · Cited by 1,189
Adsorption of dyes on chitin. I. Equilibrium studies
McKay, G., Blair, H. S., & Gardner, J. R. (1982) · Journal of Applied Polymer Science · doi:10.1002/app.1982.070270827 · Cited by 926
Characterization of hydroxyapatite and carbonated apatite by photo acoustic FTIR spectroscopy
REHMAN, I., & BONFIELD, W. (1997) · Journal of Materials Science: Materials in Medicine · doi:10.1023/a:1018570213546 · Cited by 859
Raynaud, S., Champion, E., Bernache-Assollant, D., & Thomas, P. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00218-6 · Cited by 790
Removal of cadmium from aqueous solutions by adsorption onto orange waste
Pérez-Marín, A. B., Zapata, V. M., Ortuño, J. F., Aguilar, M., Sáez, J., & Lloréns, M. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2006.06.008 · Cited by 689
Lead Immobilization from Aqueous Solutions and Contaminated Soils Using Phosphate Rocks
Ma, Q. Y., Logan, T. J., & Traina, S. J. (1995) · Environmental Science & Technology · doi:10.1021/es00004a034 · Cited by 492
Effects of Aqueous Al, Cd, Cu, Fe(II), Ni, and Zn on Pb Immobilization by Hydroxyapatite
Ma, Q. Y., Traina, S. J., Logan, T. J., & Ryan, J. A. (1994) · Environmental Science & Technology · doi:10.1021/es00056a007 · Cited by 403
Cited by
Xue, Y., Gao, B., Yao, Y., Inyang, M., Zhang, M., Zimmerman, A. R., & Ro, K. S. (2012) · Chemical Engineering Journal · doi:10.1016/j.cej.2012.06.116 · Cited by 784
Sheela, T., Nayaka, Y. A., Viswanatha, R., Basavanna, S., & Venkatesha, T. G. (2012) · Powder Technology · doi:10.1016/j.powtec.2011.10.023 · Cited by 396
Ali, I. (2010) · Separation & Purification Reviews · doi:10.1080/15422119.2010.527802 · Cited by 340
Removal of cadmium, copper, nickel, cobalt and mercury from water by Apatite II™: Column experiments
Oliva, J., De Pablo, J., Cortina, J.-L., Cama, J., & Ayora, C. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2011.07.104 · Cited by 132
Metadata
- Authors
- Corami, A., Mignardi, S., & Ferrini, V.
- Venue
- Journal of Colloid and Interface Science
- Publisher
- Elsevier BV
- Published
- 2008-01
- Volume
- 317
- Issue
- 2
- Pages
- 402-408
- ISSN
- 0021-9797 (ISSN-L)
- OpenAlex
- W2025510687
- Cited by
- 318
- References
- 31
- FWCI
- 15.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cadmium removal from single- and multi-metal () solutions by sorption on hydroxyapatite. https://app.cochat.ai/papers/10.1016/j.jcis.2007.09.075
- The paper
- Corami, A., Mignardi, S., & Ferrini, V. (2008). Cadmium removal from single- and multi-metal () solutions by sorption on hydroxyapatite. Journal of Colloid and Interface Science. https://doi.org/10.1016/j.jcis.2007.09.075
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.