Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 267

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Time-dependent ion selectivity in capacitive charging of porous electrodes

Open access
Zhao, R., van Soestbergen, M., Rijnaarts, H.H.M., van der Wal, A., Bazant, M.Z., Biesheuvel, P.M.·2012·Journal of Colloid and Interface Science

Abstract

In a combined experimental and theoretical study, we show that capacitive charging of porous electrodes in multicomponent electrolytes may lead to the phenomenon of time-dependent ion selectivity of the electrical double layers (EDLs) in the electrodes. This effect is found in experiments on capacitive deionization of water containing NaCl/CaCl(2) mixtures, when the concentration of Na(+) ions in the water is five times the Ca(2+)-ion concentration. In this experiment, after applying a voltage difference between two porous carbon electrodes, first the majority monovalent Na(+) cations are preferentially adsorbed in the EDLs, and later, they are gradually replaced by the minority, divalent Ca(2+) cations. In a process where this ion adsorption step is followed by washing the electrode with freshwater under open-circuit conditions, and subsequent release of the ions while the cell is short-circuited, a product stream is obtained which is significantly enriched in divalent ions. Repeating this process three times by taking the product concentrations of one run as the feed concentrations for the next, a final increase in the Ca(2+)/Na(+)-ratio of a factor of 300 is achieved. The phenomenon of time-dependent ion selectivity of EDLs cannot be explained by linear response theory. Therefore, a nonlinear time-dependent analysis of capacitive charging is performed for both porous and flat electrodes. Both models attribute time-dependent ion selectivity to the interplay between the transport resistance for the ions in the aqueous solution outside the EDL, and the voltage-dependent ion adsorption capacity of the EDLs. Exact analytical expressions are presented for the excess ion adsorption in planar EDLs (Gouy-Chapman theory) for mixtures containing both monovalent and divalent cations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcis.2012.06.022

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 267

Metadata

Authors
Zhao, R., van Soestbergen, M., Rijnaarts, H. H. M., van der Wal, A., Bazant, M. Z., & Biesheuvel, P. M.
Venue
Journal of Colloid and Interface Science
Publisher
Elsevier BV
Published
2012-10
Volume
384
Issue
1
Pages
38-44
ISSN
0021-9797 (ISSN-L)
OpenAlex
W2019297132
Cited by
267
References
2
FWCI
8.37
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time-dependent ion selectivity in capacitive charging of porous electrodes. https://app.cochat.ai/papers/10.1016/j.jcis.2012.06.022
The paper
Zhao, R., van Soestbergen, M., Rijnaarts, H. H. M., van der Wal, A., Bazant, M. Z., & Biesheuvel, P. M. (2012). Time-dependent ion selectivity in capacitive charging of porous electrodes. Journal of Colloid and Interface Science. https://doi.org/10.1016/j.jcis.2012.06.022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.