A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index; 4 of the 29 sources its claims cite were checked for support.
Abstract
OBJECTIVE: Intraclass correlation coefficient (ICC) is a widely used reliability index in test-retest, intrarater, and interrater reliability analyses. This article introduces the basic concept of ICC in the content of reliability analysis. DISCUSSION FOR RESEARCHERS: There are 10 forms of ICCs. Because each form involves distinct assumptions in their calculation and will lead to different interpretations, researchers should explicitly specify the ICC form they used in their calculation. A thorough review of the research design is needed in selecting the appropriate form of ICC to evaluate reliability. The best practice of reporting ICC should include software information, "model," "type," and "definition" selections. DISCUSSION FOR READERS: When coming across an article that includes ICC, readers should first check whether information about the ICC form has been reported and if an appropriate ICC form was used. Based on the 95% confident interval of the ICC estimate, values less than 0.5, between 0.5 and 0.75, between 0.75 and 0.9, and greater than 0.90 are indicative of poor, moderate, good, and excellent reliability, respectively. CONCLUSION: This article provides a practical guideline for clinical researchers to choose the correct form of ICC and suggests the best practice of reporting ICC parameters in scientific publications. This article also gives readers an appreciation for what to look for when coming across ICC while reading an article.
Overview
CoChat Summary
TL;DR
This article provides a practical guideline for selecting and reporting intraclass correlation coefficients (ICCs) in reliability research, emphasizing that different ICC forms involve different assumptions and interpretations. It recommends reporting the ICC model, type, definition, software, and 95% confidence intervals, and interpreting reliability based on the confidence interval rather than the ICC estimate alone.
Key findings
- McGraw and Wong defined 10 ICC forms based on “Model” (1-way random, 2-way random, or 2-way fixed/mixed effects), “Type” (single rater/measurement or mean of k raters/measurements), and “Definition” (consistency or absolute agreement); selection for interrater reliability is guided by 4 questions.
- For test-retest and intrarater reliability, the paper recommends the 2-way mixed-effects model and absolute agreement, with selection depending on whether the actual application uses a single measurement or the mean of multiple measurements.
- As a rule of thumb, the paper suggests at least 30 heterogeneous samples and at least 3 raters whenever possible; ICC values less than 0.5 indicate poor reliability, 0.5–0.75 moderate, 0.75–0.9 good, and greater than 0.90 excellent.
- In a hypothetical SPSS example with 3 raters across 30 subjects, the obtained ICC was 0.932 (excellent) with a 95% confidence interval of 0.879–0.965, leading the authors to conclude the reliability level was “good” to “excellent.”
Methods
- Design: methodological guideline/tutorial for clinical researchers and readers, not an empirical reliability study.
- Data or sample: no primary sample or dataset; the paper uses conceptual explanations, tables, figures, and hypothetical examples, including a case with 35 scoliosis patients measured 3 times.
- Main analysis: narrative synthesis of ICC selection and reporting principles, referencing McGraw and Wong and Shrout and Fleiss, with suggested reporting items and interpretation guidance.
Limitations
- The paper states there are no standard values for acceptable reliability using ICC, and that a low ICC may reflect low agreement, lack of variability among sampled subjects, a small number of subjects, or a small number of raters.
- The paper states that the ICC estimate from a reliability study is only an expected value of the true ICC, so it recommends evaluating reliability using the 95% confidence interval rather than the ICC estimate itself.
- Evident from the text: the recommendations are presented as rule-of-thumb guidance and are illustrated with hypothetical examples rather than validated in a primary empirical study or systematic review.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
2 Valid · 1 Not valid · 8 Not checked · 11 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Nowadays, ICC has been widely used in conservative care medicine to evaluate interrater, test-retest, and intrarater reliability (see Table 2 for their definitions).10–17”
- Also stated in: § Conclusion · plain
“It has been widely used in conservative care medicine to evaluate interrater, test-retest, and intrarater reliability of numerical or continuous measurements.”
- Also stated in: § Introduction · plain
“Given that ICC is a widely used reliability index in the literature, an understanding of ICC will help readers to make sense of their own clinical practices and to better interpret published studies.”
What the sources say
- Partly supportedcites [10] matched to “Reliability of Zygapophysial Joint Space Measurements Made from Magnetic Resonance Imaging Scans of Acute Low Back Pain Subjects: Comparison of 2 Statistical Methods” (2010) sourceExperimental — accuracy not yet measured
The Methods (Reliability Study; page not provided) use ICCs to assess reliability across observers and across measurements repeated by the same observer at least four weeks apart. The Introduction also refers to previous use of ICCs, but this paper does not establish that they are widely used across conservative care medicine. (LLM, conf=0.82)
- Not checked — no full text of the sourcecites [11] matched to “Paraspinal Skin Temperature Patterns: An Interexaminer and Intraexaminer Reliability Study” (2004) source
- Not checked — no full text of the sourcecites [12] matched to “A Mechano-Acoustic Indentor System for In Vivo Measurement of Nonlinear Elastic Properties of Soft Tissue” (2011) source
- Not checked — no full text of the sourcecites [13] matched to “Reliability of detection of lumbar lateral shift” (2003) source
- Partly supportedcites [14] matched to “Comparison of two methods of collecting healthcare usage data in chiropractic clinics: patient-report versus documentation in patient files” (2014) sourceExperimental — accuracy not yet measured
The Methods > Data analysis section uses ICC to assess agreement between patient-reported and file-recorded chiropractic visits. This supports an example of ICC use in conservative care, but the paper does not establish that ICC is widely used or address interrater, test-retest, and intrarater reliability specifically. (LLM, conf=0.86)
- Not checked — no full text of the sourcecites [15] matched to “Reliability of the Goutallier Classification in Quantifying Muscle Fatty Degeneration in the Lumbar Multifidus Using Magnetic Resonance Imaging” (2014) source
- Not checked — no full text of the sourcecites [16] matched to “PulStar differential compliance spinal instrument: a randomized interexaminer and intraexaminer reliability study” (2003) source
- Partly supportedcites [17] matched to “Measurement of lumbar lordosis in static standing posture with and without high-heeled shoes” (2012) sourceExperimental — accuracy not yet measured
The Participant exclusions section says the study used intraclass correlation to assess intra- and interexaminer reliability, and the Results report ICCs for both. The paper does not establish that ICC is widely used across conservative care medicine or identify its use here to assess test–retest reliability. (LLM, conf=0.82)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Conclusion · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“There are different forms of ICC that can give different results when applied to the same set of data”
- Also stated in: § Introduction · plain
“Fig 2 illustrates how different forms of ICC can give different results when applied to the same set of data”
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Introduction · plain
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“(5) For the same ICC definition (eg absolute agreement), ICC estimates of both the 2-way random- and mixed-effects models are the same because they use the same formula to calculate the ICC (Table 3).”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“(3) The “absolute agreement” definition generally gives a smaller ICC estimate than the “consistency” definition.”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“(4) One-way random-effects model generally gives a smaller ICC estimate than the 2-way models.”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
6 more claims
Create a free account to see all 22 claims and every source verdict.
- It may state two separate claims as one. 5
- Probably not a substantial claim. 6
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The ICC values of the subscale scores were higher than .70 for both factor models, except for Factor 3 (.65) in the 3-factor model, indicating that the test-retest reliability of the J-VLQAC is moderate level according to Koo and Li (2016)' criteria and met an appropriate standard of reliability (ICC ≥ .70, Barrett et al., 2019).”
From Reliability and validity of the Japanese version of the Valued Living Questionnaire Adapted to Caregiving (2023) · cites this paper as Koo and Li (2016)
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Test-retest reliability was assessed using intraclass correlation coefficients (ICC). Descriptive categories for ICCs are poor (<0.50), moderate (0.50−0.74), good (0.75−0.90), or excellent (>0.90) [33,40], and a priori good or excellent classifications were deemed suitable.”
From Psychometric Evaluation of Social Cognition and Behavior Measures in Children and Adolescents with Down Syndrome (2021) · cites this paper as [40]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Based on the guidelines by Koo and Li (2016) [45], a two-way mixed-effects, absolute agreement, single-measures model [ICC (3,1)], was selected.”
From Intra-Rater and Test–Retest Reliability of Kinovea for the Kinematic Analysis of Squatting in Healthy Active Women (2026) · cites this paper as Koo and Li (2016) [45]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“While ICC is standard practice for evaluating inter-rater reliability and test-retest consistency in clinical settings, it has not been systematically applied to agentic AI evaluation, where variance arises from both task difficulty and agent stochasticity.”
From Stochasticity in Agentic Evaluations: Quantifying Inconsistency with Intraclass Correlation (2025) · cites this paper as Koo and Li 2016
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“ICC ≥ 0.75 : Good reliability.”
From Stochasticity in Agentic Evaluations: Quantifying Inconsistency with Intraclass Correlation (2025) · cites this paper as Koo and Li 2016
Experimental — accuracy not yet measured
13 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Foundations of Clinical Research: Applications to Practice,
(2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00362-4 · Cited by 9,489
Forming inferences about some intraclass correlation coefficients.
McGraw, K. O., & Wong, S. P. (1996) · Psychological Methods · doi:10.1037/1082-989x.1.1.30 · Cited by 6,903
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
The Intraclass Correlation Coefficient as a Measure of Reliability
Bartko, J. J. (1966) · Psychological Reports · doi:10.2466/pr0.1966.19.1.3 · Cited by 2,299
Estimation of the reliability of ratings.
Ebel, R. L. (1951) · Psychometrika · doi:10.1007/bf02288803 · Cited by 976
Statistical Methods for Research Workers.
Anscombe, F. J., & Fisher, R. A. (1955) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2342720 · Cited by 835
Reliability: what is it, and how is it measured?
Bruton, A., Conway, J. H., & Holgate, S. T. (2000) · Physiotherapy · doi:10.1016/s0031-9406(05)61211-4 · Cited by 763
Cited by
Items 15,901–16,000 of 28,949
Gu, T., Guo, H., & Song, X. (2018) · Aging Medicine · doi:10.1002/agm2.12031 · Cited by 2
Validation of a Limitations in Daily Activities Scale for Chronic Pain
Wilson, K. G., Castillo, D., Kowal, J., Yong, A. G., & McWilliams, L. A. (2018) · Journal of Pain · doi:10.1016/j.jpain.2018.08.004 · Cited by 5
Trevino, R. C., Majcher, C., Henry, A., Rodriguez, M., & Sponsel, W. E. (2018) · Clinical ophthalmology · doi:10.2147/opth.s166211 · Cited by 4
Gesbert, V., von Roten, F. C., & Hauw, D. (2018) · Europe PMC (PubMed Central) · Cited by 8
Longmuir, P. E., Jackson, J., Ertel, E., Bhatt, M., Doja, A., Duffy, C. M., Gardin, L., Juřenčák, R., Katz, S. L., Lai, L., et al. (2018) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2018-0314 · Cited by 3
Christensen, J., Tang, L. H., Doherty, P., Langhorn, C., & Langberg, H. (2019) · European Journal of Physiotherapy · doi:10.1080/21679169.2019.1578824 · Cited by 3
Meis, M., Krueger, M., von Gablenz, P., Holube, I., Gebhard, M., Latzel, M., & Paluch, R. (2018) · Trends in Hearing · doi:10.1177/2331216518816201 · Cited by 5
Determination of the Optimal Location for Bone Graft Harvest in the Distal Radius
Matson, A. P., Federer, A. E., Meisel, E. M., et al. (2019) · Hand · doi:10.1177/1558944719832041 · Cited by 3
Obesity perception survey among youth in Turkey: instrument development and test-retest reliability
Jayawardene, W. P., Pınar, S., Torabi, M., Xun, P., & Özer, M. K. (2019) · TURKISH JOURNAL OF MEDICAL SCIENCES · doi:10.3906/sag-1811-56 · Cited by 4
Quantitative characterization of ex vivo breast tissue via x-ray phase-contrast tomography
Li, X., Chen, Z., Zhang, L., et al. (2019) · Journal of X-Ray Science and Technology · doi:10.3233/xst-180453 · Cited by 3
Lintmeijer, L. L., Onneweer, J. P. T., Hofmijster, M. J., et al. (2019) · PLoS ONE · doi:10.1371/journal.pone.0215674 · Cited by 3
Toward the Development of a Quick, Reliable Assessment Tool for Reflective Journals
Garrity, A. W., Keck, C. S., Bradshaw, J. L., & Ishikawa, K. (2019) · ISU Red - Research and eData (Illinois State University) · doi:10.30707/tlcsd3.2garrity · Cited by 4
Acceptable Noise Level Stability Over a One-Year Period of Time
Bryan, M. F., Gordon-Hickey, S., Hay, A. L., et al. (2019) · Journal of the American Academy of Audiology · doi:10.3766/jaaa.19044 · Cited by 3
Effect of Match Play on Shoulder Strength in Amateur Rugby Union Players
Zelinski, S., Manvell, J. J., Manvell, N., Callister, R., & Snodgrass, S. J. (2019) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000003208 · Cited by 3
Kavanagh, J., Moran, K., & Issartel, J. (2019) · Physical Education and Sport Pedagogy · doi:10.1080/17408989.2019.1700497 · Cited by 5
Developing the Synergy Model Patient Acuity Tool for Admission, Discharge, and Transfer
Byrum, D. G., Caulfield, E., Burgess, J. D., et al. (2020) · American Journal of Critical Care · doi:10.4037/ajcc2020204 · Cited by 3
Sullivan‐Bolyai, S., Bova, C., & Johnson, K. (2020) · The Science of Diabetes Self-Management and Care · doi:10.1177/0145721720907055 · Cited by 3
Kumar, S. S., Liu, X., Sherwin, C. M. T., et al. (2020) · Frontiers in Pharmacology · doi:10.3389/fphar.2020.00227 · Cited by 3
Hu, J., Bergquist, P. J., Hossain, R., Ropp, A. M., Kligerman, S. J., Amin, S., Sechrist, J. W., Patel, P., Jeudy, J. J., & WHITE, C. S. (2020) · Journal of Thoracic Imaging · doi:10.1097/rti.0000000000000503 · Cited by 5
Image Distortion in Biplanar Slot Scanning: Patient-specific Factors
Welborn, M. C., Bouton, D., Baksh, N., et al. (2020) · Journal of Pediatric Orthopaedics · doi:10.1097/bpo.0000000000001547 · Cited by 3
Development and applicability of a smartphone torch based emergency light source for microscopy
Mondal, H., Mondal, S., & Das, D. (2020) · Indian Journal of Pathology and Microbiology · doi:10.4103/ijpm.ijpm_263_19 · Cited by 3
Pike, M., Jager, L. B.-D., le Roux, T., & Hofmeyr, L. M. (2020) · Frontiers in Neurology · doi:10.3389/fneur.2020.00305 · Cited by 3
Psychometric Testing of Shopping Mall Universal Design Assessment Tool (SM-UD)
Abdullah, R. J., & Tang, J. W. (2020) · International Journal of Built Environment and Sustainability · doi:10.11113/ijbes.v7.n2.497 · Cited by 3
Munabi, I. G., Mwaka, E., Kirum, G. G., et al. (2020) · OALib · doi:10.4236/oalib.1106230 · Cited by 3
Hayakawa, J., Ochi, M., Yano, Y., Matsugaki, R., Ogata, Y., Murakami, T., Kuhara, S., Itoh, H., Hachisuka, K., & Saeki, S. (2020) · Journal of Stroke Medicine · doi:10.1177/2516608520921104 · Cited by 3
Dokken, I., Brovold, T., & Hesseberg, K. (2020) · Physiotherapy Research International · doi:10.1002/pri.1857 · Cited by 4
Exavery, A., Charles, J., Kuhlik, E., Barankena, A., Ally, A., Mbwambo, T., Kyaruzi, C., Mubyazi, G. M., Kikoyo, L., & Jere, E. (2020) · HIV/AIDS - Research and Palliative Care · doi:10.2147/hiv.s259074 · Cited by 3
Golmohammadi, G., Zarifian, T., Ghanbari, S., Bakhshi, E., & Sakhai, F. (2020) · Current Psychology · doi:10.1007/s12144-020-00918-7 · Cited by 3
Which one restores in vivo knee kinematics effectively-medial or lateral pivot?
Batra, S., Sugumar, P. A. A., Kumar, V., & Malhotra, R. (2020) · Journal of Clinical Orthopaedics and Trauma · doi:10.1016/j.jcot.2020.08.014 · Cited by 3
Vašíčková, J., Cuberek, R., & Pernicová, H. (2020) · Tělesná kultura · doi:10.5507/tk.2020.007 · Cited by 4
Translation, validity and reliability of the Danish version of the Adolescent Insomnia Questionnaire
Andreucci, A., Straszek, C. L., Rathleff, M. S., Guldhammer, C., de la Vega, R., & Palermo, T. M. (2020) · F1000Research · doi:10.12688/f1000research.25832.1 · Cited by 5
Establishing Reliability of a Reaction Time Testing Battery in High School Athletes
Gray, H., Williams, R. M., McLeod, T. C. V., et al. (2020) · Athletic Training & Sports Health Care · doi:10.3928/19425864-20200310-01 · Cited by 3
CEViNEdit: improving the process of creating cognitively effective graphical editors with GMF
Granada, D., Vara, J. M., Merayo, M. G., & Marcos, E. (2020) · Software & Systems Modeling · doi:10.1007/s10270-020-00833-2 · Cited by 3
Howell, S., Varley, R. A., Sinnott, E. L., Pring, T., & Beeke, S. (2020) · Aphasiology · doi:10.1080/02687038.2020.1836315 · Cited by 3
Wan, K., Cheung, S. W., Wolffsohn, J. S., et al. (2020) · Contact Lens and Anterior Eye · doi:10.1016/j.clae.2020.10.003 · Cited by 3
Du, J., Liang, P., He, H., Tong, Q., Gong, T., Qian, T., Sun, Y., Zhong, J., & Li, K. (2020) · Acta Radiologica · doi:10.1177/0284185120963919 · Cited by 3
Møller, J. M., Østergaard, M., Thomsen, H. S., et al. (2020) · BJR|Open · doi:10.1259/bjro.20200004 · Cited by 3
Reliability in ultrasound measurements of plantar aponeurosis thickness
Heinen, E. H., Lima, K. M. M. E., Correia, R. F., Diefenthaeler, F., & Fontana, H. D. B. (2020) · The Foot · doi:10.1016/j.foot.2020.101749 · Cited by 3
Vilca, L. W., Echabaudes-Ilizarbe, R. I., Aquino-Hidalgo, J. M., Ventura‐León, J., Martinez‐Munive, R., & White, M. (2020) · Psychological Reports · doi:10.1177/0033294120981930 · Cited by 4
Transposition and Normalization of the Mini-Mental State Examination in French Sign Language
Fleurion, D., Verdun, S., Ridoux, I., et al. (2020) · Archives of Clinical Neuropsychology · doi:10.1093/arclin/acaa125 · Cited by 3
Rezaei, S., Ezzati, K., Yousefzadeh-Chabok, S., & Reihanian, Z. (2020) · Archives of Trauma Research · doi:10.4103/atr.atr_14_20 · Cited by 3
Validation and Reliability of Sizestream 3D Scanner for Human Body Measurement
Tiwari, M., & Anand, N. (2020) · Springer eBooks · doi:10.1007/978-981-15-9376-5_2 · Cited by 3
Nasir, Z. M., Azman, M. B., Baki, M. M., et al. (2021) · Surgical and Radiologic Anatomy · doi:10.1007/s00276-020-02639-9 · Cited by 3
Rezapour, M., & Ksaibati, K. (2021) · Signals · doi:10.3390/signals2010004 · Cited by 3
Geiser, G. G. C. (2020) · doi:10.3278/6004819w · Cited by 3
Positional Differences in Pre-Season Scrimmage Performance of Division I Collegiate Football Players
Early, K. S., Lemoine, N. P., Simoneaux, A. B., Mullenix, S., Marucci, J., MacLellan, M. J., & Johannsen, N. M. (2021) · Sensors · doi:10.3390/s21030769 · Cited by 3
Sharman, J., Rodrigues, D., McGuirk, S. P., Panikkar, M., Nishikawa, H., Dover, S., Evans, M., & White, N. (2021) · Child s Nervous System · doi:10.1007/s00381-021-05064-4 · Cited by 3
Psychometric properties of the Turkish version of L'Insalata Shoulder Rating Questionnaire
Yaşar, P., Karakaya, İ. Ç., & Karakaya, M. G. (2021) · Disability and Rehabilitation · doi:10.1080/09638288.2021.1906958 · Cited by 3
Eitivipart, A. C., Arora, M., de Oliveira, C. Q., Heard, R. C., Middleton, J. W., & Davis, G. M. (2021) · Disability and Rehabilitation · doi:10.1080/09638288.2021.1913246 · Cited by 4
Pérez-Fentes, D., Baltar, C. F., Otero, J. N., Gil, R. D., & Sampedro, F. G. (2021) · Editor-in-Chief s Voice List of Authors is an Important Element in a Scientific Publication · doi:10.5173/ceju.2021.0339.r1 · Cited by 3
Astermark, J., Olsson, A., Chelle, P., et al. (2021) · Haemophilia · doi:10.1111/hae.14329 · Cited by 3
Burden of illness in blood eosinophilic phenotype COPD patients in New Zealand
Shantakumar, S., Ho, Y.-F., Beale, J., & Gribben, B. (2021) · Respiratory Investigation · doi:10.1016/j.resinv.2021.03.009 · Cited by 3
Park, S., Kim, J. H., Joo, I., et al. (2021) · Abdominal Radiology · doi:10.1007/s00261-021-03127-3 · Cited by 3
Mustafa, R. A., & Abuaffan, A. H. (2021) · The Journal of Contemporary Dental Practice · doi:10.5005/jp-journals-10024-3065 · Cited by 3
Reliability of Manually Segmenting T1ρ Magnetic Resonance Sequences of Talar Articular Cartilage
Song, K., Kosik, K. B., Gribble, P. A., et al. (2021) · Journal of Sport Rehabilitation · doi:10.1123/jsr.2020-0502 · Cited by 3
O’Hoski, S., Richardson, J. A., Kuspinar, A., et al. (2021) · COPD Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412555.2021.1934821 · Cited by 3
Sun, X., Zhang, X., Wang, L., Li, Y., Muir, D. C. G., & Zeng, E. Y. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.126746 · Cited by 4
Liu, P.-L., Chang, C.-C., Lin, J., et al. (2021) · PLoS ONE · doi:10.1371/journal.pone.0254814 · Cited by 3
Construction and Validation of a Generational Identity Scale on Bangladeshi Older Adults
Islam, A., & Haque, S. (2021) · Frontiers in Psychology · doi:10.3389/fpsyg.2021.703237 · Cited by 6
Design thinking and creativity of colocated versus globally distributed software developers
Jolak, R., Wortmann, A., Liebel, G., Umuhoza, E., & Chaudron, M. R. V. (2021) · Journal of Software Evolution and Process · doi:10.1002/smr.2377 · Cited by 7
Santos, P. L. D. A., Gaspar, R. C., Padula, N., et al. (2021) · Arquivos de Neuro-Psiquiatria · doi:10.1590/0004-282x-anp-2020-0366 · Cited by 3
Nakashima, Y., Iwaki, D., Kawae, T., et al. (2021) · PLoS ONE · doi:10.1371/journal.pone.0256561 · Cited by 3
Evaluation of transverse maxillary growth on cone-beam computed tomography images
Seubert, B., Gaalaas, L. R., Larson, B. E., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-97082-0 · Cited by 3
Snegireva, N., Derman, W. E., Patricios, J., & Welman, K. E. (2021) · Experimental Brain Research · doi:10.1007/s00221-021-06205-6 · Cited by 4
Hsu, K., Liang, C., Peng, Y.-C., et al. (2021) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2021.06.013 · Cited by 3
Kumar, A., Sinha, S., Jameel, J., et al. (2021) · Cureus · doi:10.7759/cureus.18285 · Cited by 3
Hanphitakphong, P., Poomsalood, S., Chamroon, C., & Udomkichpagon, P. (2021) · Biomedical Human Kinetics · doi:10.2478/bhk-2022-0001 · Cited by 3
Cowan, T., Pham, A. T., Elvevåg, B., & Cohen, A. S. (2021) · Psychiatry Research Communications · doi:10.1016/j.psycom.2021.100011 · Cited by 3
Picot, B., Dury, J., Néron, G., Samozino, P., Terrier, R., Rémy‐Néris, O., & Forestier, N. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.10.022 · Cited by 3
Test-Retest Reliability of Unilateral Horizontal Drop Jump in Children
Dukarić, V., Antekolović, L., Baković, M., et al. (2021) · Sustainability · doi:10.3390/su132112084 · Cited by 3
Proposal of a New Specific Test to Assess the Aerobic Performance in Judo
Foresti, Y. F., dos Santos, D. R. A., de Souza, R. A., & Higino, W. P. (2021) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2021.1905762 · Cited by 7
Seah, L. J. Y., Seow, D., Mahmood, D. T. F. B., et al. (2021) · Radiography · doi:10.1016/j.radi.2021.11.005 · Cited by 3
Mostert, J. M., Romeijn, S. R., Dibbets‐Schneider, P., Rietbergen, D. D. D., Arias‐Bouda, L. M. P., Götz, C., DiFranco, M. D., Dimai, H. P., & Grootjans, W. (2021) · Archives of Osteoporosis · doi:10.1007/s11657-021-01046-w · Cited by 4
Salmasi, S., Högg, T., Safari, A., Vera, M. A. D., Lynd, L. D., Koehoorn, M. W., Barry, A. R., Andrade, J. G., & Loewen, P. S. (2022) · American Journal of Epidemiology · doi:10.1093/aje/kwab295 · Cited by 4
Strifler, Y., Zisenwine, T., & Diamond, G. M. (2022) · Journal of Marital and Family Therapy · doi:10.1111/jmft.12581 · Cited by 3
Validation and Reliability of the Japanese Version of the Modified Parkinson Activity Scale (M-PAS)
Taniguchi, S., Nakata, Y., Inoue, M. B., & Marumoto, K. (2021) · Progress in Rehabilitation Medicine · doi:10.2490/prm.20210051 · Cited by 3
Ribeiro, H. G. G., Costa, V. D. S. P., Fillis, M. M. A., Alves, T. B., Puzzi, V. C., dos Santos, G. A., Porto, K. P., Trevisan, B. M., de Oliveira, J. M., & Furlanetto, K. C. (2022) · Research Society and Development · doi:10.33448/rsd-v11i2.25494 · Cited by 3
Parnes, Y., Pincus, T., Sullivan, M. J. L., & Ami, N. B. (2022) · Disability and Rehabilitation · doi:10.1080/09638288.2022.2036255 · Cited by 3
Hernaiz‐Leonardo, J. C., Alqunaee, M., Moghimi, S., et al. (2022) · International Forum of Allergy & Rhinology · doi:10.1002/alr.22985 · Cited by 3
Montes, S. C., Bennett, D., Bensinger, E. S., et al. (2022) · Translational Vision Science & Technology · doi:10.1167/tvst.11.2.35 · Cited by 3
Biometry of width between labial transitional line angles in anterior teeth: an observational study
Wen, C., Ye, H., Chen, H., et al. (2022) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2022.14.1.1 · Cited by 3
Self-report and facial expression indicators of team cohesion development
Bonny, J. W. (2022) · Behavior Research Methods · doi:10.3758/s13428-022-01799-3 · Cited by 4
Reliability of step vergence method for assessing fusional vergence in intermittent exotropia
Ma, M. M.-L., Kang, Y., Scheiman, M. M., et al. (2022) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12972 · Cited by 3
Reliability and validity of the Slovenian Translation of the Functional Oral Intake Scale (FOIS-SI)
Vogrinčič, B., Trpkova, K., & Bajrović, F. F. (2022) · Slovenian Medical Journal · doi:10.6016/zdravvestn.3167 · Cited by 3
Wu, S.-Y., Kang, H., & Jensen, J. L. (2022) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2022.2043329 · Cited by 3
Dix, C., Arundale, A. J. H., Silvers-Granelli, H. J., Marmon, A. R., Zarzycki, R., Arch, E. S., & Snyder‐Mackler, L. (2022) · Journal of ISAKOS Joint Disorders & Orthopaedic Sports Medicine · doi:10.1016/j.jisako.2022.03.002 · Cited by 4
Is it Possible to Use the HCR-20 V2 to Assess the Risk of Violent Recidivism of French Offenders?
Bertsch, I., Courtois, R., Gallard, E., et al. (2022) · Forensic Sciences Research · doi:10.1080/20961790.2022.2046370 · Cited by 3
Hsia, Y., Huang, H.-C., & Chang, W.-C. (2022) · Applied immunohistochemistry & molecular morphology · doi:10.1097/pai.0000000000001020 · Cited by 3
Schaefer, L. V., & Bittmann, F. N. (2021) · European Journal of Translational Myology · doi:10.4081/ejtm.2020.9553 · Cited by 3
Szmuda, T., Żydowicz, W. M., Ali, S., Fedorow, K., & Słoniewski, P. (2021) · Journal of Psychiatry and Mental Health · doi:10.16966/2474-7769.141 · Cited by 8
Elifranji, Z. O., Yasin, M. S., Al-Saber, M., et al. (2022) · Current Orthopaedic Practice · doi:10.1097/bco.0000000000001117 · Cited by 3
Caterini, J. E., Rendall, K., Cifra, B., Schneiderman, J. E., Ratjen, F. A., Seed, M., Rayner, T., Weiss, R., McCrindle, B. W., Noseworthy, M. D., et al. (2022) · Physiological Reports · doi:10.14814/phy2.15182 · Cited by 2
Development of a live coding method to assess infant/toddler food acceptance
Moding, K. J., Bonvecchio, A., Rawlinson, C., et al. (2022) · Maternal and Child Nutrition · doi:10.1111/mcn.13348 · Cited by 3
Gürsoy, D. E., Gezer, H. H., Kasman, S. A., & Duruöz, M. T. (2022) · Rheumatology International · doi:10.1007/s00296-022-05150-z · Cited by 5
The Short-Term Reliability of the Conceptualised ‘Combat Readiness Assessment’
Moore, D. C., Tayler, M. A., & Moore, S. C. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19116486 · Cited by 3
Moreno-Espinosa, A. L., Hawkins-Villarreal, A., Burgos-Artizzu, X. P., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-13047-x · Cited by 3
Alsaadi, S. M., Ahmed, R., Alotaibi, K., Alzahrani, M. A., ALOTAIBI, N. E. S., Alahmri, F., & Subbarayalu, A. V. (2022) · Rehabilitation Research and Practice · doi:10.1155/2022/6229847 · Cited by 5
Within- and Between-Session Reliability of Corticospinal Excitability in the Upper Extremity
Takeno, K., Norte, G. E., Glaviano, N. R., et al. (2022) · Measurement in Physical Education and Exercise Science · doi:10.1080/1091367x.2022.2070434 · Cited by 3
Real-time assessment of anteroposterior stability of spinal segments
Cornaz, F., Haupt, S., Farshad, M., et al. (2022) · European Spine Journal · doi:10.1007/s00586-022-07286-9 · Cited by 3
Testing dynamic balance in youth female volleyball players: development, reliability and usefulness
Đolo, K., Grgantov, Z., & Jelaska, I. D. (2022) · Human Movement · doi:10.5114/hm.2023.116635 · Cited by 3
Metadata
- Authors
- Koo, T. K., & Li, M. Y.
- Affiliations
- New York Chiropractic College (US)
- Corresponding author
- Koo, Terry K.
- ORCID
- Koo, Terry K.
- Venue
- Journal of Chiropractic Medicine
- Published
- 2016-06
- Volume
- 15
- Issue
- 2
- Pages
- 155-163
- ISSN
- 1556-3707 (ISSN-L)
- PMC
- PMC4913118
- OpenAlex
- W2327037637
- Cited by
- 31,709
- References
- 21
- Citations by year
- 2026: 6362 · 2025: 5028 · 2024: 4641 · 2023: 4018 · 2022: 3596 · 2021: 3221 · 2020: 2434 · 2019: 1489 · 2018: 731 · 2017: 123 · 2016: 10
- FWCI
- 406.58
- Type
- journal article
- Language
- en
- Update notices
- erratum (2017-12-01)
- Open access
- bronze
- doi.org
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Chiropractic Medicine (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Social Sciences › Decision Sciences › Management Science and Operations Research › Psychometric Methodologies and Testing
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Keywords
- intraclass correlation coefficient, reliability analysis, test-retest reliability, inter-rater reliability, intra-rater reliability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-16, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-16 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.