OBJECTIVES We sought to establish the relationship between invasive measures of diastolic function and untwisting parameters measured with speckle tracking imaging. BACKGROUND Left ventricular (LV) diastolic function is determined by early diastolic relaxation (which creates suction gradients for LV filling) and myocardial stiffness. Assessment of LV torsion has shown that untwisting begins before aortic valve closure and, in animals, might be an important component of normal diastolic filling. Studies in human subjects using indirect indexes derived from right heart catheterization have suggested a relationship between tau and measures of untwisting, but the relationship between directly measured diastolic function indexes with micromanometer catheters and untwisting parameters has not been established in human subjects. METHODS Simultaneous Millar micromanometer LV pressure and echocardiographic assessment was performed on 18 patients (10 male, mean age 66 years) with normal systolic function and a spectrum of diastolic function. Invasive rate of the rise of LV pressure, dp/dt minimum and tau were recorded as measures of active relaxation, and the LV minimum diastolic pressure was recorded as an index of diastolic suction. The LV stiffness constant and functional chamber stiffness were estimated from hybrid pressure-volume loops. Echocardiographic speckle tracking imaging was used to quantify torsion. RESULTS As relaxation was impaired, (prolonged tau) untwisting was delayed (r = 0.35, p < 0.01). There were nonsignificant associations between reduced untwisting and longer values of tau and lower dp/dt minimum. Reduction in the extent of untwisting before mitral valve opening was associated with increased LV minimum diastolic pressure (r = -0.30, p < 0.034). No relation was observed between the LV stiffness constant (beta: r = 0.11, p = NS) or the functional LV chamber stiffness (b: r = 0.11, p = NS) and untwisting. CONCLUSIONS Untwisting parameters are related to invasive indexes of LV relaxation and suction but not to LV stiffness. These data suggest that untwisting is an important component of early diastolic LV filling but not later diastolic events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcmg.2009.01.015

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 144

Metadata

Authors
Burns, A. T., La Gerche, A., Prior, D. L., & MacIsaac, A. I.
Venue
JACC: Cardiovascular Imaging
Publisher
Elsevier BV
Published
2009-06
Volume
2
Issue
6
Pages
709-716
ISSN
  • 1876-7591 (ISSN-L)
  • 1936-878X
OpenAlex
W2085215354
Cited by
144
References
3
FWCI
7.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.