Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 220

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

LV Thrombus Detection by Routine Echocardiography

Open access
Weinsaft, Jonathan W., Kim, Han W., Crowley, Anna Lisa, Klem, Igor, Shenoy, Chetan, Van Assche, Lowie, Brosnan, Rhoda, Shah, Dipan J., Velazquez, Eric J., Parker, Michele, Judd, Robert M., Kim, Raymond J. · 2011 · JACC: Cardiovascular Imaging

Abstract

Objectives To evaluate performance characteristics of routine echo for LV thrombus (LVT). Background While the utility of dedicated echocardiography (echo) for LVT is established, echo is widely used as a general test for which LVT is rarely the primary indication. We used delayed enhancement cardiac magnetic resonance (DE-CMR) as a reference to evaluate LVT detection by routine echo. Methods Dedicated LVT assessment using DE-CMR was prospectively performed in patients with LV systolic dysfunction. Echoes were done as part of routine clinical care. Echo and CMR were independently read for LVT and related indices of LVT size, shape, and image quality/diagnostic confidence. Follow-up was done for embolic events and pathology validation of LVT. Results 243 patients had routine clinical echo and dedicated CMR within 1 week without intervening events. Follow-up supported DE-CMR as a reference standard, with >5-fold difference in endpoints between patients with vs. without LVT by DE-CMR (p=0.02). LVT prevalence was 10% by DE-CMR. Echo contrast was used in 4% of patients. Echo sensitivity and specificity were 33% and 91%, with positive and negative predictive values of 29% and 93%. Among patients with possible LVT as the clinical indication for echo, sensitivity and positive predictive value were markedly higher (60%, 75%). Regarding sensitivity, echo performance related to LVT morphology and mirrored cine-CMR, with protuberant thrombus typically missed when small (p≤0.02). There was also a strong trend to miss mural thrombus irrespective of size (p=0.06). Concerning positive predictive value, echo performance related to image quality, with lower diagnostic confidence scores for echoes read positive for LVT in discordance with DE-CMR compared to echoes concordant with DE-CMR (p<0.02). Conclusions Routine echo with rare contrast use can yield misleading results concerning LVT. Echo performance is improved when large protuberant thrombus is present and when the clinical indication is specifically for LVT assessment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcmg.2011.03.017

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 220

Metadata

Authors
Weinsaft, J. W., Kim, H. W., Crowley, A. L., Klem, I., Shenoy, C., Van Assche, L., Brosnan, R., Shah, D. J., Velazquez, E. J., Parker, M., Judd, R. M., & Kim, R. J.
Venue
JACC: Cardiovascular Imaging
Publisher
Elsevier BV
Published
2011-07
Volume
4
Issue
7
Pages
702-712
ISSN
  • 1876-7591 (ISSN-L)
  • 1936-878X
OpenAlex
W2138671502
Cited by
220
References
1
FWCI
5.74
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.