The relationship between microparticle (MP) size and lung targeting efficiency, intra-lung distribution and retention time was systematically studied after intravenous administration of rigid fluorescent polystyrene MPs of various sizes (2, 3, 6 and 10μm) to Sprague-Dawley rats. Total fluorescence was assessed and it was found that 2μm and 3μm MPs readily passed through the lung to the liver and spleen while 10μm MPs were completely entrapped in the lung for the one-week duration of the study. Approximately 84% of 6μm MPs that were initially entrapped in the lung were cleared over the next 2 days and 15% were cleared over the remaining 5 days. A Caliper IVIS® 100 small animal imaging system confirmed that 3μm MPs were not retained in the lung but that 6μm and 10μm MPs were widely distributed throughout the lung. Moreover, histologic examination showed MP entrapment in capillaries but not arterioles. These studies suggest that for rigid MPs the optimal size range required to achieve transient but highly efficiently targeting to pulmonary capillaries after IV injection is >6μm but <10μm in rats and that systemic administration of optimally sized MPs may be an efficient alternative to currently used inhalation-based delivery to the lung.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jconrel.2009.12.019

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 117

Metadata

Authors
Kutscher, H. L., Chao, P., Deshmukh, M., Singh, Y., Hu, P., Joseph, L. B., Reimer, D. C., Stein, S., Laskin, D. L., & Sinko, P. J.
Venue
Journal of Controlled Release
Publisher
Elsevier BV
Published
2010-04-02
Volume
143
Issue
1
Pages
31-37
ISSN
0168-3659 (ISSN-L)
OpenAlex
W2095990690
Cited by
117
References
0
FWCI
6.64
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Threshold size for optimal passive pulmonary targeting and retention of rigid microparticles in rats. https://app.cochat.ai/papers/10.1016/j.jconrel.2009.12.019
The paper
Kutscher, H. L., Chao, P., Deshmukh, M., Singh, Y., Hu, P., Joseph, L. B., Reimer, D. C., Stein, S., Laskin, D. L., & Sinko, P. J. (2010). Threshold size for optimal passive pulmonary targeting and retention of rigid microparticles in rats. Journal of Controlled Release. https://doi.org/10.1016/j.jconrel.2009.12.019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.