A new tool to ensure the fluorescent dye labeling stability of nanocarriers: A real challenge for fluorescence imaging
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Numerous studies on nanocarriers use fluorescent dye labeling to investigate their biodistribution or cellular trafficking. However, when the fluorescence dye is not grafted to the nanocarrier, the question of the stability of the labeling arises. How can it be validated that the fluorescence observed during an experiment corresponds to the nanocarriers, and not to the free dye released from the nanocarriers? Studying the integrity of the labeling is challenging. Therefore, an innovative approach to confirm the labeling stability was developed, based on the transfer of a fluorescent dye from its hosting nanocarrier to a lipophilic compartment. Lipid nanocapsules (LNC) and triglyceride oil were used as models. The protocol involved mixing of LNC suspension and oil, and then separation by centrifugation. The quality of the separation was controlled by light scattering, using the derived count rate tool. Dye transfer from loaded LNCs to the lipophilic compartment or from a lipophilic compartment containing dye to non-loaded LNC was investigated by varying the nature of the dye and the oil, the oil volume and the LNC dilution. Tensiometry was used to define the dye location in the nanocarrier. Results showed that when dyes such as Nile Red and Coumarin-6 are located in oily core, the transfer occurred in a partition-dependent manner. In contrast, when the dye was entrapped in the surfactant shell of LNCs such as lipophilic indocarbocyanines (i.e. DiO, DiI and DiD), no transfer was observed. Dye diffusion was also observed in cell culture, with Nile Red inside lipid bodies of HEI-OC1 cells, without uptake of LNCs. In contrast, DiO-loaded LNCs had to be internalized to observe fluorescence inside the cells, providing a further confirmation of the absence of transfer in this case, and the stability of fluorescence labeling of the LNCs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spectrofluorometric studies of the lipid probe, nile red.
Greenspan, P., & Fowler, S. D. (1985) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)34307-8 · Cited by 980
Gaumet, M., Gurny, R., & Delie, F. (2009) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2008.11.015 · Cited by 115
Development of a nanoparticle-based system for the delivery of retinoic acid into macrophages
Almouazen, E., Bourgeois, S., Boussaïd, A., Valot, P., Malleval, C., Fessi, H., Nataf, S., & Briançon, S. (2012) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2012.03.025 · Cited by 47 · cited 2×
“It should also confirm the cellular trafficking results obtained with mesenchymal stromal cells [33], Caco-2 cells [6,34,35], macrophages [5], malignant rat-glioma cells (F98) [9], etc.”
BackgroundResult
Cited by
Nanostructured lipid carriers: Promising drug delivery systems for future clinics
Beloqui, A., Solinís, M. Á., Rodríguez-Gascón, A., Almeida, A. J., & Préat, V. (2016) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2015.09.004 · Cited by 769
Yang, Z.-Z., Li, J.-Q., Wang, Z.-Z., Dong, D.-W., & Qi, X.-R. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.017 · Cited by 267
Cai, L., Xu, G., Shi, C., Guo, D., Wang, X., & Luo, J. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.044 · Cited by 151
“The amphiphilic dye DiI has been demonstrated to be a stable probe molecule to trap the intracellular trafficking of polymer micelles [31].”
BackgroundZhu, Y., Meng, T., Tan, Y., Yang, X., Liu, Y., Liu, X., Yu, F., Wen, L., Dai, S., Yuan, H., et al. (2018) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.8b00842 · Cited by 42
Liu, Y., Fens, M. H. A. M., Capomaccio, R. B., Mehn, D., Scrivano, L., Kok, R. J., Oliveira, S., Hennink, W. E., & van Nostrum, C. F. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.10.040 · Cited by 25
Metadata
- Authors
- Bastiat, G., Pritz, C. O., Roider, C., Fouchet, F., Lignières, E., Jesacher, A., Glueckert, R., Ritsch-Marte, M., Schrott-Fischer, A., Saulnier, P., & Benoit, J.-P.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 2013-09
- Volume
- 170
- Issue
- 3
- Pages
- 334-342
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W2061999464
- Cited by
- 115
- References
- 3
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new tool to ensure the fluorescent dye labeling stability of nanocarriers: A real challenge for fluorescence imaging. https://app.cochat.ai/papers/10.1016/j.jconrel.2013.06.014
- The paper
- Bastiat, G., Pritz, C. O., Roider, C., Fouchet, F., Lignières, E., Jesacher, A., Glueckert, R., Ritsch-Marte, M., Schrott-Fischer, A., Saulnier, P., & Benoit, J.-P. (2013). A new tool to ensure the fluorescent dye labeling stability of nanocarriers: A real challenge for fluorescence imaging. Journal of Controlled Release. https://doi.org/10.1016/j.jconrel.2013.06.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.