The DOI matches its Crossref record; 210 of the 210 references it cites were found in a registry or an index.
PCL-PEG copolymer based injectable thermosensitive hydrogels
Open accessAbstract
A number of stimuli-responsive-based hydrogels has been widely explored in biomedical applications in the last few decades because of their excellent biodegradability and biocompatibility. The development of synthetic chemistry and materials science leads to the emergence of in situ stimuli-responsive hydrogels. In this regard, several synthetic and natural polymers have been synthesized and utilized to prepare temperature-sensitive in situ forming hydrogels. This could be best used via injections as temperature stimulus could trigger in situ hydrogels gelation and swelling behaviors. There are many smart polymers available for the formulation of the in situ based thermoresponsive injectable hydrogel. Among these, poly (ε-caprolactone) (PCL) polymer has been recognized and approved by the FDA for numerous biomedical applications. More specifically, the PCL is coupled with polyethylene glycol (PEG) to obtain amphiphilic thermosensitive “smart” copolymers (PCL-PEG), to form rapid and reversible physical gelation behavior. However, the chemical structure of the copolymer is a critical aspect in determining water solubility, thermo-gelation behavior, drug release rate, degradation rate, and the possibility to deliver a diverse range of drugs. In this review, we have highlighted the typical PCL-PEG-based thermosensitive injectable hydrogels progress in the last decade for tissue engineering and localized drug delivery applications to treat various diseases. Additionally, the impact of molecular weight of PCL-PEG upon gelling behavior has also been critically highlighted for optimum hydrogels properties for potential pharmaceutical and biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Items 201–210 of 210
The PLGA Implant as an Antimitotic Delivery System After Experimental Trabeculectomy
Rodríguez-Agirretxe, I., Vega, S. C., Rezola, R., Vecino, E., Mendicute, J., Suarez-Cortes, T. M., & Acera, A. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.13-11777 · Cited by 25
Chao, G., Fan, L., Jia, W., Qian, Z., Gu, Y., Liu, C., Ni, X., Li, J., Deng, H., Gong, C., et al. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-2004-2 · Cited by 23
Gou, M. L., Huang, M. J., Gou, M. L., Huang, M. J., Qian, Z. Y., Gou, M. L., Huang, M. J., Qian, Z. Y., Yang, L., Gou, M. L., et al. (2007) · Growth Factors · doi:10.1080/08977190701671613 · Cited by 22
Alexander, A., Saraf, S., & Saraf, S. (2016) · Current Drug Delivery · doi:10.2174/1567201813666160204114000 · Cited by 21
Self-citationKehoe, S. M., Williams, N. L., Yakubu, R., Levine, D. A., Dennis, S., Sabbatini, P. J., Aghajanian, C. A., Barakat, R. R., & Abu‐Rustum, N. R. (2009) · Gynecologic Oncology · doi:10.1016/j.ygyno.2009.01.016 · Cited by 19
Fu, S., Guo, G. F., Wang, X.-L., Zhou, L., Liu, T., Dong, P., Luo, F., Gu, Y., Shi, X., Zhao, X., et al. (2010) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2010.1888 · Cited by 17
Enzymatic Polymerization of PCL-PEG Co-polymers for Biomedical Applications
Figueiredo, P., Almeida, B. C., & Carvalho, A. T. P. (2019) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2019.00109 · Cited by 16
Liao, W., Yang, Z., Deng, L., Li, X., Sun, T., Luo, J., Qin, T., & Xie, H. (2005) · PubMed · Cited by 4
[Experimental study on repair of goat tibia defect with marrow stromal cell and bio-derived bone].
Qi, C., Yang, Z., Huang, F., Qin, T., Li, X., Luo, J., & Cai, Y. (2005) · PubMed · Cited by 4
Lu (1999) · doi:10.1002/(sici)1097-4636(199908)46:2
Cited by
Novel Trends in Hydrogel Development for Biomedical Applications: A Review
Sánchez-Cid, P., Jiménez-Rosado, M., Romero, A., & Pérez-Puyana, V. (2022) · Polymers · doi:10.3390/polym14153023 · Cited by 321
Biomaterials / bioinks and extrusion bioprinting
Chen, X. B., Fazel Anvari-Yazdi, A., Duan, X., Zimmerling, A., Gharraei, R., Sharma, N. K., Sweilem, S., & Ning, L. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.06.006 · Cited by 244
“Coupling PCL with polyethylene glycol (PEG) causes amphiphilic thermosensitive behavior meaning the mixture is able to undergo rapid and reversible physical gelation by controlling the temperature [97].”
BackgroundResorbable Biomaterials Used for 3D Scaffolds in Tissue Engineering: A Review
Vach Agocsova, S., Culenova, M., Birova, I., Omanikova, L., Moncmanova, B., Danisovic, L., Ziaran, S., Bakos, D., & Alexy, P. (2023) · Materials · doi:10.3390/ma16124267 · Cited by 98
Ehlen, Q. T., Costello, J. P., Mirsky, N. A., Slavin, B. V., Parra, M., Ptashnik, A., Nayak, V. V., Coelho, P. G., & Witek, L. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c01279 · Cited by 29
Metadata
- Authors
- Dethe, M. R., A, P., Ahmed, H., Agrawal, M., Roy, U., & Alexander, A.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 2022-03
- Volume
- 343
- Pages
- 217-236
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W4206956868
- Cited by
- 263
- References
- 210
- FWCI
- 14.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.