Calibrate, emulate, sample
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Many parameter estimation problems arising in applications are best cast in the framework of Bayesian inversion. This allows not only for an estimate of the parameters, but also for the quantification of uncertainties in the estimates. Often in such problems the parameter-to-data map is very expensive to evaluate, and computing derivatives of the map, or derivative-adjoints, may not be feasible. Additionally, in many applications only noisy evaluations of the map may be available. We propose an approach to Bayesian inversion in such settings that builds on the derivative-free optimization capabilities of ensemble Kalman inversion methods. The overarching approach is to first use ensemble Kalman sampling (EKS) to calibrate the unknown parameters to fit the data; second, to use the output of the EKS to emulate the parameter-to-data map; third, to sample from an approximate Bayesian posterior distribution in which the parameter-to-data map is replaced by its emulator. This results in a principled approach to approximate Bayesian inference that requires only a small number of evaluations of the (possibly noisy approximation of the) parameter-to-data map. It does not require derivatives of this map, but instead leverages the documented power of ensemble Kalman methods. Furthermore, the EKS has the desirable property that it evolves the parameter ensembles towards the regions in which the bulk of the parameter posterior mass is located, thereby locating them well for the emulation phase of the methodology. In essence, the EKS methodology provides a cheap solution to the design problem of where to place points in parameter space to efficiently train an emulator of the parameter-to-data map for the purposes of Bayesian inversion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monte Carlo sampling methods using Markov chains and their applications.
Hastings, W. K. (1970) · Biometrika · doi:10.1093/biomet/57.1.97 · Cited by 15,195 · cited 1×
“MCMC methods [31, 54,55] and sequential Monte Carlo (SMC) [18] provide the primary examples of such methods, and their practical success underpins the widespread interest in the Bayesian solution of inverse problems [39].”
MethodMetropolis, N., & Ulam, S. (1949) · Journal of the American Statistical Association · doi:10.1080/01621459.1949.10483310 · Cited by 6,474 · cited 1×
“MCMC methods [31, 54,55] and sequential Monte Carlo (SMC) [18] provide the primary examples of such methods, and their practical success underpins the widespread interest in the Bayesian solution of inverse problems [39].”
MethodBayesian calibration of computer models
Kennedy, M. C., & O'Hagan, A. (2001) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/1467-9868.00294 · Cited by 4,222
Atmospheric Modeling, Data Assimilation and Predictability
Kalnay, E. (2002) · doi:10.1017/cbo9780511802270 · Cited by 3,391 · cited 3×
“alman sampling; Gaussian process emulation; experimental design. 1. INTRODUCTION Ensemble Kalman methods have proven to be highly successful for state estimation in noisily observed dynamical systems [1,6,13,19,31,37,42,47]. They are widely used, especially California Institute of Technology, Pasadena, CA. (ecleary@ca…”
BackgroundMethodData Assimilation: The Ensemble Kalman Filter
Evensen, G. (2009) · doi:10.1007/978-3-642-03711-5 · Cited by 1,180
Schneider, T., Lan, S., Stuart, A., & Teixeira, J. (2017) · Geophysical Research Letters · doi:10.1002/2017gl076101 · Cited by 391
Self-citation
Cited by
Are general circulation models obsolete?
Balaji, V., Couvreux, F., Deshayes, J., Gautrais, J., Hourdin, F., & Rio, C. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2202075119 · Cited by 84
Machine learning for the physics of climate
Bracco, A., Brajard, J., Dijkstra, H. A., Hassanzadeh, P., Lessig, C., & Monteleoni, C. (2024) · Nature Reviews Physics · doi:10.1038/s42254-024-00776-3 · Cited by 79
Opinion: Optimizing climate models with process knowledge, resolution, and artificial intelligence
Schneider, T., Leung, L. R., & Wills, R. C. J. (2024) · Atmospheric Chemistry and Physics · doi:10.5194/acp-24-7041-2024 · Cited by 53
Self-citation
Metadata
- Authors
- Cleary, E., Garbuno-Inigo, A., Lan, S., Schneider, T., & Stuart, A. M.
- Venue
- Journal of Computational Physics
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 424
- Pages
- 109716
- ISSN
- 0021-9991 (ISSN-L)
- OpenAlex
- W3040929669
- Cited by
- 129
- References
- 6
- FWCI
- 11.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibrate, emulate, sample. https://app.cochat.ai/papers/10.1016/j.jcp.2020.109716
- The paper
- Cleary, E., Garbuno-Inigo, A., Lan, S., Schneider, T., & Stuart, A. M. (2021). Calibrate, emulate, sample. Journal of Computational Physics. https://doi.org/10.1016/j.jcp.2020.109716
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.