The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK
Abstract
PURPOSE: To assess the performance of the Pascal dynamic contour tonometer (PDCT) (Swiss Microtechnology AG) by comparing it to Goldmann applanation tonometry (GAT) and noncontact air tonometry (NCT) before and after laser in situ keratomileusis (LASIK). SETTING: Vlemma Eye Institute, Athens, Greece. METHODS: Intraocular pressure was measured in 118 eyes before and 1 and 4 weeks after LASIK using GAT, NCT, and the PDCT, which allows direct, digital, transcorneal measurement of intraocular pressure. RESULTS: Preoperatively, central corneal thickness (CCT) correlated with GAT and NCT measurements but not with PDCT measurements. After LASIK, the mean reduction in CCT ranged from -3.0 to -171.0 microm (median 78 microm). The mean GAT measurement dropped by -4.9 mm Hg +/- 2.7 (SD) at 1 week and was -5.4 +/- 3.0 mm Hg at 4 weeks. Similar drops were observed in NCT measurements. The observed post-LASIK changes in GAT and NCT IOP measurements were not directly proportional to the change in CCT, refractive error, or mean keratometric readings. The preoperative and postoperative PDCT measurements did not differ significantly. CONCLUSIONS: The structural corneal changes induced by LASIK appeared to influence GAT and NCT measurements but not PDCT measurements. Therefore, PDCT may be better suited for monitoring IOP in unoperated eyes and in eyes that have had LASIK.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The specific architecture of the anterior stroma accounts for maintenance of corneal curvature
Muller, L. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.437 · Cited by 424
Cited by
Liu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753
Pepose, J. S., Feigenbaum, S. K., Qazi, M. A., Sanderson, J. P., & Roberts, C. J. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.09.036 · Cited by 369
Tonnu, P.-A. (2005) · British Journal of Ophthalmology · doi:10.1136/bjo.2004.056622 · Cited by 357
Surveillance for ocular hypertension: an evidence synthesis and economic evaluation.
Burr, J., Botello-Pinzon, P., Takwoingi, Y., Hernández, R., Vazquez-Montes, M., Elders, A., Asaoka, R., Banister, K., van der Schoot, J., Fraser, C., et al. (2012) · Health Technology Assessment · doi:10.3310/hta16290 · Cited by 180
Ocular Pulse Amplitude in Healthy Subjects as Measured by Dynamic Contour Tonometry
Kaufmann, C. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.8.1104 · Cited by 154
Metadata
- Authors
- Siganos, D. S., Papastergiou, G. I., & Moedas, C.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2004-04
- Volume
- 30
- Issue
- 4
- Pages
- 746-751
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W1964400875
- Cited by
- 170
- References
- 1
- FWCI
- 10.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. https://app.cochat.ai/papers/10.1016/j.jcrs.2003.12.033
- The paper
- Siganos, D. S., Papastergiou, G. I., & Moedas, C. (2004). Assessment of the Pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/j.jcrs.2003.12.033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.