The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus
Abstract
PURPOSE: To evaluate whether the corneal-thickness spatial profile and corneal-volume distribution differentiate keratoconic corneas from normal corneas using new tomography parameters. SETTING: Subspecialty cornea and refractive practice, Fluminense Federal University, Rio de Janeiro, Brazil. METHODS: Forty-six eyes diagnosed with mild to moderate keratoconus and 364 normal eyes were studied by the Pentacam Comprehensive Eye Scanner. Corneal thickness at the thinnest point and the averages of the points on 22 imaginary circles centered on the thinnest point with increased diameters at 0.4 mm steps were calculated to create a corneal-thickness spatial profile. Corneal volume was calculated within diameters from 1.0 to 7.0 mm with 0.5 mm steps centered on the thinnest point to create the corneal-volume distribution. The percentage increase in thickness and the percentage increase in volume were calculated for each position of the corneal-thickness spatial profile and corneal-volume distribution from their first value. Statistical analysis was done using the Wilcoxon 2-independent-sample test to compare mean levels using S-Plus-4.0 software (MathSoft) and a normal linear model under a Bayesian frame for estimating the mean variation in thickness and volume using the BUGS 0.6 package. RESULTS: Statistically significant differences were observed between the groups (P<.05) in all positions of corneal-thickness spatial profile and corneal-volume distribution and in the percentage increase in thickness and percentage increase in volume between 3.5 mm and 7.0 mm diameters. CONCLUSIONS: Corneal-thickness spatial profile, corneal-volume distribution, percentage increase in thickness, and percentage increase in volume were different between keratoconic corneas and normal corneas and could serve as indices to diagnose keratoconus and screen refractive candidates. Further studies are necessary to evaluate whether these tomographic indices are more sensitive and specific than the classic Placido-based topography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rabinowitz, Y. S. (1998) · Survey of Ophthalmology · doi:10.1016/s0039-6257(97)00119-7 · Cited by 2,744
Gordon, M. O. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.714 · Cited by 2,626
Keratoconus and related noninflammatory corneal thinning disorders
Krachmer, J. H., Feder, R. S., & Belin, M. W. (1984) · Survey of Ophthalmology · doi:10.1016/0039-6257(84)90094-8 · Cited by 1,598
Risk factors and prognosis for corneal ectasia after LASIK
Randleman, J. B., Russell, B., Ward, M. A., Thompson, K. P., & Stulting, R. D. (2003) · Ophthalmology · doi:10.1016/s0161-6420(02)01727-x · Cited by 690
Rabinowitz, Y. S., & Rasheed, K. (1999) · Journal of Cataract & Refractive Surgery · doi:10.1016/s0886-3350(99)00195-9 · Cited by 475
Automated keratoconus screening with corneal topography analysis.
Maeda, N., Klyce, S. D., Smolek, M. K., et al. (1994) · PubMed · Cited by 438
Computer-Assisted Corneal Topography in Keratoconus
Rabinowitz, Y. S., & McDonnell, P. J. (1989) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19891101-10 · Cited by 395
CLEMENT, M., & SEKULICH, M. (1944) · What Is Tuberculosis? · doi:10.1016/b978-1-4831-8000-7.50006-7 · Cited by 387
The Ocular Hypertension Treatment Study
Kass, M. A. (1994) · Journal of Glaucoma · doi:10.1097/00061198-199400320-00001 · Cited by 368
Barkana, Y., Gerber, Y., Elbaz, U., Schwartz, S., Ken-Dror, G., Avni, I., & Zadok, D. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2005.03.058 · Cited by 298
Cited by
Novel Pachymetric Parameters Based on Corneal Tomography for Diagnosing Keratoconus
Ambrósio, R., Caiado, A. L. C., Guerra, F. P., Louzada, R., Roy, A. S., Luz, A., Dupps, W. J., & Belin, M. W. (2011) · Journal of Refractive Surgery · doi:10.3928/1081597x-20110721-01 · Cited by 349
Self-citationMeasuring the Refractive Index of Bovine Corneal Stromal Cells Using Quantitative Phase Imaging
Gardner, S. J., White, N., Albon, J., Knupp, C., Kamma-Lorger, C. S., & Meek, K. M. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.08.046 · Cited by 17
Metadata
- Authors
- Ambrósio, R., Alonso, R. S., Luz, A., & Coca Velarde, L. G.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2006-11
- Volume
- 32
- Issue
- 11
- Pages
- 1851-1859
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2170466279
- Cited by
- 451
- References
- 17
- FWCI
- 8.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus. https://app.cochat.ai/papers/10.1016/j.jcrs.2006.06.025
- The paper
- Ambrósio, R., Alonso, R. S., Luz, A., & Coca Velarde, L. G. (2006). Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/j.jcrs.2006.06.025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.