Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 286

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements

Shankar, Hema, Taranath, Deepa, Santhirathelagan, Chandramalar T., Pesudovs, Konrad·2008·Journal of Cataract and Refractive Surgery

Abstract

PURPOSE: To comprehensively assess the reliability of automated Pentacam (Oculus, Inc.) measurements. SETTING: Flinders Eye Centre, Flinders Medical Centre, Bedford Park, South Australia, Australia. METHODS: Both eyes of 35 normal volunteers were tested twice on the same day by 2 different observers. All automated values were recorded, and manual analysis of topographic maps was performed only to overrule variance in corneal thickness due to pupil decentration altering the central reference point. Repeatability was determined with Bland-Altman limits of agreement and reported as the coefficient of repeatability (COR = +/-1.96 standard deviation of differences). Relative repeatability (RR) was calculated as a percentage of the ratio of COR to the mean. RESULTS: Overall, repeatability was good. Corneal curvature, reported in diopters, showed good repeatability anteriorly (simulated keratometry mean COR+/-0.28D; RR=0.64%) and posteriorly (COR+/-011D; RR=1.85%). Peripheral corneal curvature was more reliable when calculated by the sagittal (axial) method (RR=1.57%) than by the tangential (meridional) method (RR=2.38%). Keratometric power deviation was less reliable (RR=16.39%). Anterior chamber measurements showed good reliability (RR=3.07%-5.68%) except for anterior chamber angle (RR=14.41%). Pupil diameter showed poor reliability (RR=25.77%). Central corneal thickness was comparable at pupil center and corneal vertex, but peripheral repeatability was much better when centered on the corneal vertex (COR+/-16.00microm; RR=2.56%) than at pupil center (COR+/-26.28microm; RR=4.23%). CONCLUSIONS: Pentacam corneal curvature and anterior chamber parameters were highly repeatable, but pupil measurements had poor repeatability. Peripheral pachymetry readings were affected by pupil decentration and required manual analysis using the corneal vertex as the point of reference to achieve good repeatability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcrs.2007.09.013

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Metadata

Authors
Shankar, H., Taranath, D., Santhirathelagan, C. T., & Pesudovs, K.
Venue
Journal of Cataract and Refractive Surgery
Published
2008-01
Volume
34
Issue
1
Pages
103-113
ISSN
  • 0146-2776 (ISSN-L)
  • 0886-3350
OpenAlex
W2064374944
Cited by
286
References
11
FWCI
15.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements. https://app.cochat.ai/papers/10.1016/j.jcrs.2007.09.013
The paper
Shankar, H., Taranath, D., Santhirathelagan, C. T., & Pesudovs, K. (2008). Anterior segment biometry with the Pentacam: Comprehensive assessment of repeatability of automated measurements. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/j.jcrs.2007.09.013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.