Abstract
Agreement between two methods of clinical measurement can be quantified using the differences between observations made using the two methods on the same subjects. The 95% limits of agreement, estimated by mean difference +/- 1.96 standard deviation of the differences, provide an interval within which 95% of differences between measurements by the two methods are expected to lie. We describe how graphical methods can be used to investigate the assumptions of the method and we also give confidence intervals. We extend the basic approach to data where there is a relationship between difference and magnitude, both with a simple logarithmic transformation approach and a new, more general, regression approach. We discuss the importance of the repeatability of each method separately and compare an estimate of this to the limits of agreement. We extend the limits of agreement approach to data with repeated measurements, proposing new estimates for equal numbers of replicates by each method on each subject, for unequal numbers of replicates, and for replicated data collected in pairs, where the underlying value of the quantity being measured is changing. Finally, we describe a nonparametric approach to comparing methods.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The inter-rater agreement between the two authors for quality appraisal was 85%, with Cohen's kappa = .70, indicating good to substantial agreement.
“The inter-rater agreement between the two authors was 85% (McHugh, 2012), with the inter-rater reliability score (Cohen's kappa = .70; Bland & Altman, 1999, based on Landis & Koch, 1977) indicating a good to substantial level of agreement.”
From Unraveling the Complexities of Offender Strategies as Part of Online Sexual Grooming and Technology-Assisted Child Sexual Abuse: A Systematic Review (2026) · cites this paper as Bland & Altman, 1999
Bland and Altman introduced the Bland-Altman (B&A) plot to describe agreement between two quantitative measurements.
“Bland and Altman introduced the Bland-Altman (B&A) plot to describe agreement between two quantitative measurements (6).”
From Understanding bland altman analysis (2015) · cites this paper as [6]
Bland and Altman established a method to quantify agreement between two quantitative measurements by constructing limits of agreement.
“They established a method to quantify agreement between two quantitative measurements by constructing limits of agreement.”
From Understanding bland altman analysis (2015) · cites this paper as [6]
Bland and Altman recommended that 95% of the data points should lie within ±2 standard deviations of the mean difference.
“B&A recommended that 95% of the data points should lie within ± 2s of the mean difference.”
From Understanding bland altman analysis (2015) · cites this paper as [6]
Cited by
Sorted by citations
Understanding bland altman analysis
Giavarina, D. (2015) · Biochemia Medica · doi:10.11613/bm.2015.015 · Cited by 4,022 · see citing works
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 1,864 · see citing works
Self-citationInterrater agreement and interrater reliability: Key concepts, approaches, and applications
Gisev, N., Bell, J. S., & Chen, T. F. (2013) · Research in Social and Administrative Pharmacy · doi:10.1016/j.sapharm.2012.04.004 · Cited by 924 · see citing works
The new AASM criteria for scoring hypopneas: impact on the apnea hypopnea index
Ruehland, W. R., Rochford, P. D., O’Donoghue, F. J., Pierce, R. J., Singh, P., & Thornton, A. T. (2009) · SLEEP · doi:10.1093/sleep/32.2.150 · Cited by 696 · see citing works
Celis-Morales, C. A., Perez-Bravo, F., Ibañez, L., Salas, C., Bailey, M. E. S., & Gill, J. M. R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0036345 · Cited by 486 · see citing works
Li, X., Dunn, J., Salins, D., Zhou, G., Zhou, W., Schüssler-Fiorenza Rose, S. M., Perelman, D., Colbert, E., Runge, R., Rego, S., et al. (2017) · PLOS Biology · doi:10.1371/journal.pbio.2001402 · Cited by 431 · see citing works
Diarrhoea-predominant IBS patients show mast cell activation and hyperplasia in the jejunum
Guilarte, M., Santos, J., de Torres, I., Alonso, C., Vicario, M., Ramos, L., Martinez, C., Casellas, F., Saperas, E., & Malagelada, J. R. (2007) · Gut · doi:10.1136/gut.2006.100594 · Cited by 385 · see citing works
Cecconi, M., Rhodes, A., Poloniecki, J., Della Rocca, G., & Grounds, R. M. (2009) · Critical Care · doi:10.1186/cc7129 · Cited by 351 · see citing works
Influence of hemolysis on routine clinical chemistry testing
Lippi, G., Luca Salvagno, G., Montagnana, M., Brocco, G., & Cesare Guidi, G. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.054 · Cited by 344 · see citing works
Test-retest reliability of evoked BOLD signals from a cognitive-emotive fMRI test battery.
Plichta, M. M., Schwarz, A. J., Grimm, O., Morgen, K., Mier, D., Haddad, L., Gerdes, A. B. M., Sauer, C., Tost, H., Esslinger, C., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.129 · Cited by 287 · see citing works
Thermal Indices and Thermophysiological Modeling for Heat Stress
Havenith, G., & Fiala, D. (2015) · Comprehensive Physiology · doi:10.1002/cphy.c140051 · Cited by 262 · see citing works
Detection of anaemia from retinal fundus images via deep learning
Mitani, A., Huang, A., Venugopalan, S., Corrado, G. S., Peng, L., Webster, D. R., Hammel, N., Liu, Y., & Varadarajan, A. V. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0487-z · Cited by 230 · see citing works
Methods of Blood Pressure Measurement in the ICU*
Lehman, L.-W. H., Saeed, M., Talmor, D., Mark, R., & Malhotra, A. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318265ea46 · Cited by 224 · see citing works
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226 · see citing works
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196 · see citing works
Tully, M. A., McBride, C., Heron, L., & Hunter, R. F. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-952 · Cited by 172 · see citing works
Measuring physical activity during pregnancy
Harrison, C. L., Thompson, R. G., Teede, H. J., & Lombard, C. B. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-19 · Cited by 139 · see citing works
von Wowern, E., Östling, G., Nilsson, P. M., & Olofsson, P. (2015) · PLOS ONE · doi:10.1371/journal.pone.0135659 · Cited by 134 · see citing works
Accuracy of a PDA-based dietary assessment program
Beasley, J., Riley, W. T., & Jean-Mary, J. (2005) · Nutrition · doi:10.1016/j.nut.2004.11.006 · Cited by 124 · see citing works
A non-invasive device to continuously determine heat strain in humans
Gunga, H.-C., Sandsund, M., Reinertsen, R. E., Sattler, F., & Koch, J. (2008) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2008.03.004 · Cited by 129 · see citing works
Day-to-day variability in spot urine albumin-creatinine ratio
Naresh, C. N., Hayen, A., Weening, A., Craig, J. C., & Chadban, S. J. (2013) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2013.06.016 · Cited by 107 · see citing works
Jacobs, E. M. G., Hendriks, J. C. M., van Tits, B. L. J. H., Evans, P. J., Breuer, W., Liu, D. Y., Jansen, E. H. J. M., Jauhiainen, K., Sturm, B., Porter, J. B., et al. (2005) · Analytical Biochemistry · doi:10.1016/j.ab.2005.03.008 · Cited by 101 · see citing works
Mortensen, K. H., Hjerrild, B. E., Stochholm, K., Andersen, N. H., Sørensen, K. E., Lundorf, E., Hørlyck, A., Pedersen, E. M., Christiansen, J. S., & Gravholt, C. H. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-24 · Cited by 99 · see citing works
Ball, T. J., Joy, E. A., Gren, L. H., & Shaw, J. M. (2016) · Preventing Chronic Disease · doi:10.5888/pcd13.150228 · Cited by 89 · see citing works
Tractenberg, R. E., Jonklaas, J., & Soldin, S. J. (2010) · International Journal of Analytical Chemistry · doi:10.1155/2010/234808 · Cited by 64 · see citing works
Comparing Automatic and Manual Measures of Parent–Infant Conversational Turns: A Word of Caution
Ramírez, N. F., Hippe, D. S., & Kuhl, P. K. (2021) · Child Development · doi:10.1111/cdev.13495 · Cited by 62 · see citing works
Yu, S., Powell, A., Khow, K., & Visvanathan, R. (2016) · Nutrients · doi:10.3390/nu8040189 · Cited by 58 · see citing works
Using photoplethysmography in heart rate monitoring of patients with epilepsy
van Andel, J., Ungureanu, C., Aarts, R., Leijten, F., & Arends, J. (2015) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2015.02.018 · Cited by 39 · see citing works
Lee, Q. Y., Redmond, S. J., Chan, G. S., Middleton, P. M., Steel, E., Malouf, P., Critoph, C., Flynn, G., O’Lone, E., & Lovell, N. H. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-19 · Cited by 34 · see citing works
Measurement of sodium concentration in sweat samples: comparison of 5 analytical techniques
Goulet, E. D. B., Asselin, A., Gosselin, J., & Baker, L. B. (2017) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0059 · Cited by 28 · see citing works
Therapy monitoring in congenital adrenal hyperplasia by dried blood samples
Wieacker, I., Peter, M., Borucki, K., Empting, S., Roehl, F.-W., & Mohnike, K. (2015) · Journal of Pediatric Endocrinology and Metabolism · doi:10.1515/jpem-2014-0303 · Cited by 14 · see citing works
Porcelli, C., Anderson, F., & Kloess, J. A. (2026) · Trauma, Violence, & Abuse · doi:10.1177/15248380251411261
- Authors
- Bland, J. M., & Altman, D. G.
- Affiliations
- St George's, University of London (GB)
- University of Oxford (GB)
- ORCID
- Altman, D.G.
- Venue
- Statistical Methods in Medical Research
- Publisher
- SAGE Publications
- Published
- 1999-06-01
- Volume
- 8
- Issue
- 2
- Pages
- 135-160
- ISSN
- 0962-2802 (ISSN-L)
- 1477-0334
- OpenAlex
- W2159759971
- Cited by
- 9,619
- References
- 0
- Citations by year
- 2026: 393 · 2025: 421 · 2024: 483 · 2023: 494 · 2022: 559 · 2021: 681 · 2020: 610 · 2019: 506 · 2018: 485 · 2017: 457 · 2016: 412 · 2015: 437 · 2014: 461 · 2013: 388 · 2012: 401
- FWCI
- 47.68
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Statistical Methods in Medical Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Keywords
- method comparison, measurement agreement, limits of agreement, mean difference, repeatability, regression analysis, logarithmic transformation, repeated measures, nonparametric comparison, graphical method, confidence intervals
- MeSH terms
- Humans, Medical Laboratory Science, Reproducibility of Results, Confidence Intervals, Linear Models, Statistics, Nonparametric, Clinical Laboratory Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review