Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 174

The DOI matches its Crossref record.

Significance of the riboflavin film in corneal collagen crosslinking

Wollensak, Gregor, Aurich, Henning, Wirbelauer, Christopher, Sel, Saadettin · 2010 · Journal of Cataract and Refractive Surgery

Abstract

PURPOSE: To evaluate the role of the preocular riboflavin film in ultraviolet-A (UVA) absorption in corneal collagen crosslinking (CXL). SETTING: Eye Laser Institute, Department of Ophthalmology, Martin-Luther-University, Halle, Germany. METHODS: The absorption of UVA light was measured in human donor and porcine postmortem corneas with and without riboflavin film using 3 solutions: standard dextran-riboflavin, methylcellulose-riboflavin, and hypoosmolar riboflavin-sodium chloride without dextran. The breakup time of the solutions and their absorbance were also determined. RESULTS: After 30-minute instillation of riboflavin solution, the corneal absorption coefficient of the combined stroma-riboflavin film system was 56.36 cm(-1) in human corneas and 51.46 cm(-1) in porcine corneas using dextran-riboflavin; 69.87 cm(-1) and 53.86 cm(-1), respectively, using methylcellulose-riboflavin; and 48.19 cm(-1) and 42.68 cm(-1), respectively, using hypoosmolar riboflavin. For the stroma alone without riboflavin film, the absorption coefficient was reduced to 36.95 cm(-1) in human corneas and 28.91 cm(-1) in porcine corneas using dextran-riboflavin; 38.26 cm(-1) and 32.49 cm(-1), respectively, using methylcellulose-riboflavin; and 38.88 cm(-1) and 28.42 cm(-1), respectively, using hypoosmolar riboflavin solution. The breakup time was 22 minutes for the dextran-riboflavin film, 32 minutes for methylcellulose, and 90 seconds for the hypoosmolar solution. CONCLUSION: Results indicate that the cornea including the riboflavin film can be considered a composite 2-compartment system and that the riboflavin film is an integral part of the CXL procedure and important in achieving the correct stromal and endothelial UVA irradiance. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcrs.2009.07.044

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 174

Metadata

Authors
Wollensak, G., Aurich, H., Wirbelauer, C., & Sel, S.
Venue
Journal of Cataract and Refractive Surgery
Published
2010-01
Volume
36
Issue
1
Pages
114-120
ISSN
  • 0146-2776 (ISSN-L)
  • 0886-3350
OpenAlex
W2049705176
Cited by
174
References
0
FWCI
6.58
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Significance of the riboflavin film in corneal collagen crosslinking. https://app.cochat.ai/papers/10.1016/j.jcrs.2009.07.044
The paper
Wollensak, G., Aurich, H., Wirbelauer, C., & Sel, S. (2010). Significance of the riboflavin film in corneal collagen crosslinking. Journal of Cataract and Refractive Surgery. https://doi.org/10.1016/j.jcrs.2009.07.044

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.