Influence of ultra-high strength infill in slender concrete-filled steel tubular columns
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper describes 24 tests conducted on slender circular tubular columns filled with normal, high, and ultra-high strength concrete for plain, bar reinforced and steel fiber reinforced columns. These were reinforced and subjected to both concentric and eccentric axial load. It is a continuation of a previous research paper (Portoles et al., 2011 [1] ), which presented test results on eccentrically loaded plain concrete columns. The test parameters are nominal strength of concrete (30, 90 and 130 MPa), eccentricity e (0, 20 and 50 mm) and type of reinforcement. A comparison with the corresponding empty tubular columns is performed, as the aim of the paper is to analyze the influence of each type of infill and establish the best option for practical application. For the limited cases analyzed the results show that the addition of high or ultra-high strength infill is more useful for concentric loaded cases than for eccentric loaded ones, where it seems that the best design option is the utilization of bar reinforced concrete filling rather than steel fiber to reinforce CFST columns. The experimental ultimate load of each test was compared with the design loads from Eurocode 4, accurate for the eccentrically loaded tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultra-High Strength Concrete Filled Composite Columns for Multi-Storey Building Construction
Liew, J. Y. R., & Xiong, D. X. (2012) · Advances in Structural Engineering · doi:10.1260/1369-4332.15.9.1487 · Cited by 170
Cited by
Design of Concrete Filled Tubular Beam-columns with High Strength Steel and Concrete
Liew, J. Y. R., Xiong, M., & Xiong, D. (2016) · Structures · doi:10.1016/j.istruc.2016.05.005 · Cited by 262
Analysis and review of concrete-filled double skin steel tubes under compression
Ayough, P., Sulong, N. H. R., & Ibrahim, Z. (2020) · Thin-Walled Structures · doi:10.1016/j.tws.2019.106495 · Cited by 191
Experimental study on circular steel tube-confined reinforced UHPC columns under axial loading
Wei, J., Xie, Z., Zhang, W., Luo, X., Yang, Y., & Chen, B. (2021) · Engineering Structures · doi:10.1016/j.engstruct.2020.111599 · Cited by 172
Behavior of steel fiber reinforced concrete-filled steel tube columns under axial compression
Lu, Y., Li, N., Li, S., & Liang, H. (2015) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2015.07.114 · Cited by 159
Behaviour of steel tubular members infilled with ultra high strength concrete
Xiong, M.-X., Xiong, D.-X., & Liew, J. Y. R. (2017) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2017.07.001 · Cited by 156
Metadata
- Authors
- Portolés, J. M., Serra, E., & Romero, M. L.
- Venue
- Journal of Constructional Steel Research
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 86
- Pages
- 107-114
- ISSN
- 0143-974X (ISSN-L)
- OpenAlex
- W1965678775
- Cited by
- 101
- References
- 1
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of ultra-high strength infill in slender concrete-filled steel tubular columns. https://app.cochat.ai/papers/10.1016/j.jcsr.2013.03.016
- The paper
- Portolés, J. M., Serra, E., & Romero, M. L. (2013). Influence of ultra-high strength infill in slender concrete-filled steel tubular columns. Journal of Constructional Steel Research. https://doi.org/10.1016/j.jcsr.2013.03.016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.