Evaluation of a novel real-time RT-PCR using TOCE technology compared with culture and Seeplex RV15 for simultaneous detection of respiratory viruses
Open accessAbstract
Background Various kinds of commercial molecular systems have been developed for fast and more accurate detection of respiratory viruses. Anyplex™ II RV16 [RV16] was designed for simultaneous detection of 16 respiratory viruses using multiplex PCR coupled with TOCE™ technology. Objectives To compare the performance of RV16 with those of culture and Seeplex(®) RV15 ACE [RV15] by determining their sensitivity and specificity. Study design Seven hundred and thirty respiratory samples were tested by modified shell vial culture method, RV16, and RV15. For molecular tests, automated nucleic acid extraction and liquid handling system using MICROLAB Nimbus IVD (Hamilton, USA) was adopted to maximize the workflow and accuracy. Performance of each assay was determined against a composite reference standard. Results Two hundred and one samples (28%) out of 730 samples were positive by culture, while additional 281 (39%) were positive by RV16 or RV15. Sensitivities of RV16, RV15, and culture for virus tested were as follows: 100/93/63% for influenza A, 90/80/69% for influenza B, 98/94/63% for RSV, 98/52/23% for adenovirus, and 100/75/46% for PIV. For viruses not covered by culture, sensitivities of RV16 and RV15 were as follows: 99/81% for rhinovirus, 92/100% for coronavirus OC43, 100/56% for coronavirus 229E/NL63, 92/88% for metapneumovirus, 100/62% for bocavirus, and 91/91% for enterovirus. Overall, the specificities of culture, RV16, and RV15 (Seegene) were 100/99.9/99.9%. Conclusions RV16 assay was superior to culture method and RV15 and will be a promising tool for patient management and public health epidemiology.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
These HPV51 subtypes were likely to be suboptimally detected by H28, whose sensitivity relies on type-specific primers and probes strictly adapted to published sequences.
“They therefore were likely to be suboptimally detected by H28, whose sensitivity relies on type-specific primers and probes strictly adapted to published sequences (25).”
From Comparison of Seegene Anyplex II HPV28 with the PGMY-CHUV Assay for Human Papillomavirus Genotyping (2014) · cites this paper as [25]
The Discussion considers possible probe–target mismatches in influenza B assays, not detection of HPV51 subtypes by H28. The Analytical methods section describes respiratory-virus assays. Searches for HPV51, H28, and the claimed type-specific primers and probes found no passage addressing the claim. (LLM, conf=0.78)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 20
- [1]Mahony J.B. Petrich A. Smieja M. Molecular diagnosis of respiratory virus infections Crit Rev Clin Lab Sci 48 2011 217 249 22185616
- [2]Coiras M.T. Perez-Brena P. Garcia M.L. Casas I. Simultaneous detection of influenza A, B, and C viruses, respiratory syncytial virus, and adenoviruses in clinical samples by multiplex reverse transcription nested-PCR assay J Med Virol 69 2003 132 144 12436489
- [3]Kim S.R. Ki C.S. Lee N.Y. Rapid detection and identification of 12 respiratory viruses using a dual priming oligonucleotide system-based multiplex PCR assay J Virol Methods 156 2009 111 116 19063921 PMC7112863
- [4]Bellau-Pujol S. Vabret A. Legrand L. Dina J. Gouarin S. Petitjean-Lecherbonnier J. Development of three multiplex RT-PCR assays for the detection of 12 respiratory RNA viruses J Virol Methods 126 2005 53 63 15847919 PMC7112904
- [5]Gooskens J. Swaan C.M. Claas E.C. Kroes A.C. Rapid molecular detection of influenza outbreaks in nursing homes J Clin Virol 41 2008 7 12 18065263
- [6]Drews S.J. Blair J. Lombos E. DeLima C. Burton L. Mazzulli T. Use of the Seeplex RV detection kit for surveillance of respiratory viral outbreaks in Toronto, Ontario, Canada Ann Clin Lab Sci 38 2008 376 379 18988931
- [7]Brunstein J.D. Cline C.L. McKinney S. Thomas E. Evidence from multiplex molecular assays for complex multipathogen interactions in acute respiratory infections J Clin Microbiol 46 2008 97 102 17977985 PMC2224244
- [8]Li H. McCormac M.A. Estes R.W. Sefers S.E. Dare R.K. Chappell J.D. Simultaneous detection and high-throughput identification of a panel of RNA viruses causing respiratory tract infections J Clin Microbiol 45 2007 2105 2109 17507510 PMC1932978
- [9]Zhang G. Hu Y. Wang H. Zhang L. Bao Y. Zhou X. High incidence of multiple viral infections identified in upper respiratory tract infected children under three years of age in Shanghai, China PLoS ONE 7 2012 e44568 22970251 PMC3436764
- [10]Bibby D.F. McElarney I. Breuer J. Clark D.A. Comparative evaluation of the Seegene Seeplex RV15 and real-time PCR for respiratory virus detection J Med Virol 83 2011 1469 1475 21678451 PMC7166927
- [11]Roh K.H. Kim J. Nam M.H. Yoon S. Lee C.K. Lee K. Comparison of the Seeplex reverse transcription PCR assay with the R-mix viral culture and immunofluorescence techniques for detection of eight respiratory viruses Ann Clin Lab Sci 38 2008 41 46 18316781
- [12]Gharabaghi F. Hawan A. Drews S.J. Richardson S.E. Evaluation of multiple commercial molecular and conventional diagnostic assays for the detection of respiratory viruses in children Clin Microbiol Infect 17 2011 1900 1906 21707834 PMC7128441
- [13]Chun J.Y. High multiplex molecular diagnostics. Shifting the diagnostics paradigm Seegene Bull 1 2012 1 4 24133863
- [16]Guittet V. Brouard J. Vabret A. Lafay F. Guillois B. Duhamel J.F. Rhinovirus et infections respiratoires aiguës de l’enfant hospitalisé. Étude rétrospective de 1998 à 2000 Archiv Pediatr 10 2003 417 423 PMC7127855 12878334
- [17]van den Hoogen B.G. de Jong J.C. Groen J. Kuiken T. de Groot R. Fouchier R.A. A newly discovered human pneumovirus isolated from young children with respiratory tract disease Nat Med 7 2001 719 724 11385510 PMC7095854
- [18]van der Hoek L. Pyrc K. Jebbink M.F. Vermeulen-Oost W. Berkhout R.J. Wolthers K.C. Identification of a new human coronavirus Nat Med 10 2004 368 373 15034574 PMC7095789
- [19]Drosten C. Günther S. Preiser W. van der Werf S. Brodt H.R. Becker S. Identification of a novel coronavirus in patients with severe acute respiratory syndrome N Engl J Med 348 2003 1967 1976 12690091
- [20]Ksiazek T.G. Erdman D. Goldsmith C.S. Zaki S.R. Peret T. Emery S. A novel coronavirus associated with severe acute respiratory syndrome N Engl J Med 348 2003 1953 1966 12690092
- [21]Kim H.K. Oh S.H. Yun K.A. Sung H. Kim M.N. Comparison of Anyplex II RV16 with the xTAG respiratory viral panel and Seeplex RV15 for detection of respiratory viruses J Clin Microbiol 51 2013 1137 1141 23363824 PMC3666760
- [22]Zheng X. Todd K.M. Yen-Lieberman B. Kaul K. Mangold K. Shulman S.T. Unique finding of a 2009 H1N1 influenza virus-positive clinical sample suggests matrix gene sequence variation J Clin Microbiol 48 2010 665 666 20007396 PMC2815593
Cited by
Sorted by citations
Comparison of Seegene Anyplex II HPV28 with the PGMY-CHUV Assay for Human Papillomavirus Genotyping
Estrade, C., & Sahli, R. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.02749-13 · Cited by 57 · see citing works
- Authors
- Cho, C. H., Chulten, B., Lee, C. K., Nam, M. H., Yoon, S. Y., Lim, C. S., Cho, Y., & Kim, Y. K.
- Affiliations
- Korea University (KR)
- Corresponding author
- Lee, Chang Kyu
- Venue
- Journal of Clinical Virology
- Publisher
- Elsevier BV
- Published
- 2013-08
- Volume
- 57
- Issue
- 4
- Pages
- 338-342
- ISSN
- 1386-6532 (ISSN-L)
- PMC
- PMC7108272
- OpenAlex
- W2167345993
- Cited by
- 49
- References
- 0
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 1 · 2020: 3 · 2019: 6 · 2018: 6 · 2017: 3 · 2016: 8 · 2015: 9 · 2014: 4 · 2013: 4
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of Clinical Virology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Korea University
- Korea University Anam Hospital
- Topics
- Health Sciences › Medicine › Epidemiology › Respiratory viral infections research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Bacterial Identification and Susceptibility Testing
- Health Sciences › Medicine › Infectious Diseases › Viral gastroenteritis research and epidemiology
- Keywords
- respiratory viruses, multiplex RT-PCR, viral culture, influenza A virus, influenza B, respiratory syncytial virus, adenovirus, parainfluenza virus, rhinovirus, HCoV-OC43, HCoV-229E, coronavirus NL63, metapneumovirus, bocavirus, enterovirus, sensitivity and specificity
- MeSH terms
- Cells, Cultured, Humans, Respiratory Tract Infections, Sensitivity and Specificity, Viruses, Reverse Transcriptase Polymerase Chain Reaction, Molecular Diagnostic Techniques, Real-Time Polymerase Chain Reaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review