Adsorption mercury, cobalt, and nickel with a reclaimable and magnetic composite of hydroxyapatite/Fe3O4/polydopamine
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In the current investigation, the adsorptive performance of hydroxyapatite (HAp) was improved by using Fe3O4 magnetic nanoparticles and polydopamine (PDA) and was applied to eliminate Hg(II), Co(II), and Ni(II). The tests of XPS, XRD, EDX, FTIR, TGA, and VSM were applied to identify the HAp/Fe3O4/PDA structure and adsorption mechanisms. Based on the finding, pH was of the most effective variables in the elimination process and the highest yield was determined at pH 6 for all studied metals. The equilibrium data followed the Langmuir and Freundlich models (R2 > 0.9). According to isotherm modeling, Hg(II), Co(II), and Ni(II) removal using HAp/Fe3O4/PDA has a physical mechanism. The highest elimination capacity (qm) for Hg(II), Co(II), and Ni(II) was set at 51.73 mg/g, 49.32 mg/g, and 48.09 mg/g, respectively. The effect of contact time had a good consistency with the findings of the Weber and Morris kinetic, as the process was done in two steps. The Gibbs free energy parameter revealed that the abatement process is spontaneous and its spontaneity degree decreases with elevating temperature. Various analyzes were used to explore the characteristics of the HAp/Fe3O4/PDA composite. In summary, HAp/Fe3O4/PDA had an effective capability to remove toxic metals from distilled water and landfill leachate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adsorption of phosphorus by calcium-flour biochar: Isotherm, kinetic and transformation studies
Wang, S., Kong, L., Long, J., Su, M., Diao, Z., Chang, X., Chen, D., Song, G., & Shih, K. (2018) · Chemosphere · doi:10.1016/j.chemosphere.2017.12.101 · Cited by 244
Esvandi, Z., Foroutan, R., Peighambardoust, S. J., Akbari, A., & Ramavandi, B. (2020) · Surfaces and Interfaces · doi:10.1016/j.surfin.2020.100754 · Cited by 165
Self-citationBonyadi, Z., Kumar, P. S., Foroutan, R., Kafaei, R., Arfaeinia, H., Farjadfard, S., & Ramavandi, B. (2019) · Korean Journal of Chemical Engineering · doi:10.1007/s11814-019-0373-0 · Cited by 82
Self-citation
Cited by
Cadmium ion removal from aqueous media using banana peel biochar/Fe3O4/ZIF-67
Foroutan, R., Peighambardoust, S. J., Mohammadi, R., Peighambardoust, S. H., & Ramavandi, B. (2022) · Environmental Research · doi:10.1016/j.envres.2022.113020 · Cited by 176
Self-citation
Metadata
- Authors
- Foroutan, R., Peighambardoust, S. J., Ahmadi, A., Akbari, A., Farjadfard, S., & Ramavandi, B.
- Venue
- Journal of Environmental Chemical Engineering
- Publisher
- Elsevier BV
- Published
- 2021-08
- Volume
- 9
- Issue
- 4
- Pages
- 105709
- ISSN
- 2213-2929 (ISSN-L)
- 2213-3437
- OpenAlex
- W3163927456
- Cited by
- 170
- References
- 3
- FWCI
- 9.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.