The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Recent advances and challenges in electrochemical biosensors for emerging and re-emerging infectious diseases
Open accessAbstract
The rise of emerging infectious diseases (EIDs) as well as the increase in spread of existing infections is threatening global economies and human lives, with several countries still fighting repeated onslaught of a few of these epidemics. The catastrophic impact a pandemic has on humans and economy should serve as a reminder to be better prepared to the advent of known and unknown pathogens in the future. The goal of having a set of initiatives and procedures to tackle them is the need of the hour. Rapid detection and point-of-care (POC) analysis of pathogens causing these diseases is not only a problem entailing the scientific community but also raises challenges in tailoring appropriate treatment strategies to the healthcare sector. Among the various methods used to detect pathogens, Electrochemical Biosensor Technology is at the forefront in the development of POC devices. Electrochemical Biosensors stand in good stead due to their rapid response, high sensitivity and selectivity and ease of miniaturization to name a few advantages. This review explores the innovations in electrochemical biosensing based on the various electroanalytical techniques including voltammetry, impedance, amperometry and potentiometry and discusses their potential in diagnosis of emerging and re-emerging infectious diseases (Re-EIDs), which are potential pandemic threats.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584 · cited 1×
“An amperometric glucose biosensor itself was the stepping stone towards the development of cost effective, reliable, rapid and handy POC diagnostic devices, which then created a revolution in medical diagnosis [82].”
Cited by
Fundamentals of bio-electrochemical sensing
Shanbhag, M. M., Manasa, G., Mascarenhas, R. J., Mondal, K., & Shetti, N. P. (2023) · Chemical Engineering Journal Advances · doi:10.1016/j.ceja.2023.100516 · Cited by 273
Metadata
- Authors
- Menon, S., Mathew, M. R., Sam, S., Keerthi, K., & Kumar, K. G.
- Venue
- Journal of Electroanalytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 878
- Pages
- 114596
- ISSN
- 1572-6657 (ISSN-L)
- OpenAlex
- W3080436440
- Cited by
- 212
- References
- 1
- FWCI
- 9.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent advances and challenges in electrochemical biosensors for emerging and re-emerging infectious diseases. https://app.cochat.ai/papers/10.1016/j.jelechem.2020.114596
- The paper
- Menon, S., Mathew, M. R., Sam, S., Keerthi, K., & Kumar, K. G. (2020). Recent advances and challenges in electrochemical biosensors for emerging and re-emerging infectious diseases. Journal of Electroanalytical Chemistry. https://doi.org/10.1016/j.jelechem.2020.114596
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.