Calculating Cornell voltage from nonstandard chest electrode recording site in the Reasons for Geographic And Racial Differences in Stroke study
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background To minimize participants’ burden and the need for disrobing, a 7-lead electrocardiogram (ECG) recording using a single mid-sternal chest lead was recorded at the initial stages of The REasons for Geographic And Racial Differences in Stroke (REGARDS) Study. ECG-detected left ventricular hypertrophy (ECG-LVH) by Cornell voltage (RaVL +SV3) cannot be assessed from this method because of the absence of V3. We examined the possibility that the S wave amplitude in the mid-sternal lead (SV) could be used as a surrogate for SV3. Methods The REGARDS study is a US national study where 7-lead ECGs were performed in 8,330 (29%) participants and standard 12-lead EGCs were performed in 20,811 (71%). Cornell voltage was calculated as the sum of aVL amplitude + SV (in the 7-lead group) or SV3 (in the 12-lead group). Logistic regression analysis was used to examine and compare the magnitude of the association between the LVH risk factors with ECG-LVH in both groups, and Cox Proportional Hazards analysis was used to examine and compare the hazard ratios of overall mortality and cardiovascular mortality associated with ECG-LVH in both groups. Results Regardless of the Cornell voltage calculation method, ECG-LVH was significantly associated with LVH risk factors, and with the exception of sex there was no evidence of a difference in the magnitude of the association. ECG-LVH from both approaches were significantly and similarly associated with both all cause and cardiovascular mortality. Conclusion ECG-LVH by Cornell voltage calculated from a 7-lead ECG (using SV in the formula) has demographic and clinical associations that are similar to that calculated from a standard 12-lead ECG (using SV3). In epidemiologic studies recording 7-lead ECG, SV could be used as an alternative to SV3 in the Cornell voltage formula.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Probability of stroke: a risk profile from the Framingham Study.
Wolf, P. A., D'Agostino, R. B., Belanger, A. J., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.3.312 · Cited by 1,782 · cited 1×
“Furthermore, 12-lead ECG will provide more information regarding anterior or anterolateral myocardial infarction/ischemia as well as more options to detect electrocardiogram-detected left ventricular hypertrophy (ECG-LVH), a major risk for stroke and a component of the Framingham stroke risk score.(3) Therefore, after…”
Cited by
Baber, U., Howard, V. J., Halperin, J. L., Soliman, E. Z., Zhang, X., McClellan, W., Warnock, D. G., & Muntner, P. (2011) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.110.957100 · Cited by 247
Self-citationRevised Framingham Stroke Risk Profile to Reflect Temporal Trends
Dufouil, C., Beiser, A., McLure, L. A., Wolf, P. A., Tzourio, C., Howard, V. J., Westwood, A. J., Himali, J. J., Sullivan, L., Aparicio, H. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.115.021275 · Cited by 212
Self-citationThacker, E. L., Gillett, S. R., Wadley, V. G., Unverzagt, F. W., Judd, S. E., McClure, L. A., Howard, V. J., & Cushman, M. (2014) · Journal of the American Heart Association · doi:10.1161/jaha.113.000635 · Cited by 169
“Left ventricular hypertrophy (LVH) was defined based on ECG.(11)”
InfluentialSelf-citationVascular risk factors and cognitive impairment in a stroke-free cohort
Unverzagt, F. W., McClure, L. A., Wadley, V. G., Jenny, N. S., Go, R. C., Cushman, M., Kissela, B. M., Kelley, B. J., Kennedy, R., Moy, C. S., et al. (2011) · Neurology · doi:10.1212/wnl.0b013e318236ef23 · Cited by 152
Self-citationFibroblast Growth Factor 23 and Risk of Incident Stroke in Community-Living Adults
Panwar, B., Jenny, N. S., Howard, V. J., Wadley, V. G., Muntner, P., Kissela, B. M., Judd, S. E., & Gutiérrez, O. M. (2015) · Stroke · doi:10.1161/strokeaha.114.007489 · Cited by 65
Self-citation
Metadata
- Authors
- Soliman, E. Z., Howard, G., Prineas, R. J., McClure, L. A., & Howard, V. J.
- Venue
- Journal of Electrocardiology
- Publisher
- Elsevier BV
- Published
- 2010-05
- Volume
- 43
- Issue
- 3
- Pages
- 209-214
- ISSN
- 0022-0736 (ISSN-L)
- OpenAlex
- W2168111494
- Cited by
- 27
- References
- 1
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.