Surface EMG: The issue of electrode location
Open accessAbstract
This paper contributes to clarifying the conditions under which electrode position for surface EMG detection is critical and leads to estimates of EMG variables that are different from those obtained in other nearby locations. Whereas a number of previous works outline the need to avoid the innervation zone (or the muscle belly), many authors place electrodes in the central part or bulge of the muscle of interest where the innervation zone is likely to be. Computer simulations are presented to explain the effect of the innervation zone on amplitude, frequency and conduction velocity estimates from the signal and the need to avoid placing electrodes near it. Experimental signals recorded from some superficial muscles of the limbs and trunk (abductor pollicis brevis, flexor pollicis brevis, biceps, upper trapezius, vastus medialis, vastus lateralis) were processed providing support for the findings obtained from simulations. The use of multichannel techniques is recommended to estimate the location of the innervation zone and to properly choose the optimal position of the detection point(s) allowing meaningful estimates of EMG variables during movement analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The linear electrode array: a useful tool with many applications
Merletti, R., Farina, D., & Gazzoni, M. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00082-2 · Cited by 285 · cited 1×
“The increasing use of mathematical models (Farina and Merletti, 2001; Hogrel et al., 1998) and of electrode arrays and multichannel amplifiers (Merletti et al., 2001, 2003; Ostlund et al., 2007; Saitou et al., 2000) at the clinical research level (Beck et al., 2008; Campanini et al., 2007; Cescon…”
BackgroundSelf-citationGeometrical factors in surface EMG of the vastus medialis and lateralis muscles
Rainoldi, A., Nazzaro, M., Merletti, R., Farina, D., Caruso, I., & Gaudenti, S. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00024-9 · Cited by 192 · cited 2×
“1 and 2 explains and confirms the clinical observation that the amplitude of the EMG signal detected with a pair of electrodes has a minimum over the IZ (Beck et al., 2008; Rainoldi et al., 2000).”
BackgroundInfluentialSelf-citation
Cited by
Surface Electromyography Signal Processing and Classification Techniques
Chowdhury, R., Reaz, M., Ali, M., Bakar, A., Chellappan, K., & Chang, T. (2013) · Sensors · doi:10.3390/s130912431 · Cited by 1,000
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
MacDonald, G. Z., Penney, M. D. H., Mullaley, M. E., Cuconato, A. L., Drake, C. D. J., Behm, D. G., & Button, D. C. (2013) · Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e31825c2bc1 · Cited by 411
Tutorial. Surface EMG detection in space and time: Best practices
Merletti, R., & Muceli, S. (2019) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2019.102363 · Cited by 290
Self-citationMarcolin, G., Panizzolo, F. A., Petrone, N., Moro, T., Grigoletto, D., Piccolo, D., & Paoli, A. (2018) · PeerJ · doi:10.7717/peerj.5165 · Cited by 21
Metadata
- Authors
- Mesin, L., Merletti, R., & Rainoldi, A.
- Venue
- Journal of Electromyography and Kinesiology
- Publisher
- Elsevier BV
- Published
- 2009-10
- Volume
- 19
- Issue
- 5
- Pages
- 719-726
- ISSN
- 1050-6411 (ISSN-L)
- OpenAlex
- W1971652624
- Cited by
- 200
- References
- 2
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface EMG: The issue of electrode location. https://app.cochat.ai/papers/10.1016/j.jelekin.2008.07.006
- The paper
- Mesin, L., Merletti, R., & Rainoldi, A. (2009). Surface EMG: The issue of electrode location. Journal of Electromyography and Kinesiology. https://doi.org/10.1016/j.jelekin.2008.07.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.