A passive exoskeleton reduces peak and mean EMG during symmetric and asymmetric lifting
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The VT-Lowe's exoskeleton is a novel passive lift-assistive device designed to offload the back muscles during repetitive lifting. In this study, the effect of the exoskeleton on electromyographic (EMG) signals was investigated in four different lifting types (stoop, squat, freestyle and asymmetric) and two box weights (0% and 20% of body weight). Twelve young healthy adults ages 18-31 years (mean = 22.75, SD = 4.35) were participants. The EMG signals for twelve muscles (iliocostalis erector spinae (IL), longissimus erector spinae (LT), multifidus (MF), bicep femoris (BF), vastus lateralis (VL) and abdominal external oblique (AEO) muscles) were measured. The exoskeleton significantly decreased the peak and mean activity of back muscles (IL and LT) by 31.5% and 29.3%, respectively, for symmetric lifts and by 28.2% and 29.5%, respectively, for asymmetric lifts. The peak and mean EMG of leg muscles were significantly reduced by 19.1% and 14.1% during symmetric lifts, and 17.4% and 14.6% during asymmetric lifts. Although the exoskeleton reduced the activation of back and leg muscles, it slightly increased the activity of external oblique muscles, although this was not statistically significant. In conclusion, the exoskeleton is promising as a lift-assist device for manual material handlers and workers performing repetitive lifting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exoskeletons for industrial application and their potential effects on physical work load
de Looze, M. P., Bosch, T., Krause, F., Stadler, K. S., & O’Sullivan, L. W. (2016) · Ergonomics · doi:10.1080/00140139.2015.1081988 · Cited by 1,062
Epidemiology and Risk Factors for Spine Pain
Rubin, D. I. (2007) · Neurologic Clinics · doi:10.1016/j.ncl.2007.01.004 · Cited by 796
Bosch, T., van Eck, J., Knitel, K., & de Looze, M. (2016) · Applied Ergonomics · doi:10.1016/j.apergo.2015.12.003 · Cited by 462
Atlas of Muscle Innervation Zones
Barbero, M., Merletti, R., & Rainoldi, A. (2012) · Springer eBooks · doi:10.1007/978-88-470-2463-2 · Cited by 419
Exoskeletons and robotic prosthetics: a review of recent developments
Bogue, R. (2009) · Industrial Robot: An International Journal · doi:10.1108/01439910910980141 · Cited by 348
Active Exoskeleton Control Systems: State of the Art
Anam, K., & Al-Jumaily, A. A. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.273 · Cited by 304
Response of trunk muscle coactivation to changes in spinal stability
Granata, K. P., & Orishimo, K. F. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00081-1 · Cited by 247
Abdoli-E, M., Agnew, M. J., & Stevenson, J. M. (2006) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2005.12.021 · Cited by 218
Kim, S., Nussbaum, M. A., Mokhlespour Esfahani, M. I., Alemi, M. M., Jia, B., & Rashedi, E. (2018) · Applied Ergonomics · doi:10.1016/j.apergo.2018.02.024 · Cited by 205
Self-citationA Biomechanical Assessment and Model of Axial Twisting in the Thoracolumbar Spine
Marras, W. S., & Granata, K. P. (1995) · Spine · doi:10.1097/00007632-199507000-00002 · Cited by 204
Kuiper, J. I., Burdorf, A., Verbeek, J. H. A. M., Frings-Dresen, M. H. W., van der Beek, A. J., & Viikari-Juntura, E. R. A. (1999) · International Journal of Industrial Ergonomics · doi:10.1016/s0169-8141(99)00006-2 · Cited by 194
Effects of a passive exoskeleton on the mechanical loading of the low back in static holding tasks
Koopman, A. S., Kingma, I., Faber, G. S., de Looze, M. P., & van Dieën, J. H. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.11.033 · Cited by 192
Stokes, I. A. F., Gardner-Morse, M. G., & Henry, S. M. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2011.04.006 · Cited by 188
A Review of exoskeleton-type systems and their key technologies
Yang, C.-J., Zhang, J.-F., Chen, Y., Dong, Y.-M., & Zhang, Y. (2008) · Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science · doi:10.1243/09544062jmes936 · Cited by 187
Abdoli-Eramaki, M., & Stevenson, J. M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.10.012 · Cited by 149
Frost, D. M., Abdoli-Eramaki, M., & Stevenson, J. M. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.12.002 · Cited by 137
Multi-joint soft exosuit for gait assistance
Asbeck, A. T., Schmidt, K., Galiana, I., Wagner, D. A., & Walsh, C. J. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7140069 · Cited by 130
Self-citationStoop or Squat: A Biomechanical and Metabolic Evaluation
Garg, A., & Herrin, G. D. (1979) · A I I E Transactions · doi:10.1080/05695557908974474 · Cited by 106
Islam, R., Spiewak, C., Rahman, M., & Fareh, R. (2017) · IEEE International Conference on Robotics and Automation · doi:10.4172/2168-9695.1000177 · Cited by 96
Lower Extremity Exoskeleton Reduces Back Forces in Lifting
Wehner, M. F., Rempel, D. M., & Kazerooni, H. (2009) · ASME Dynamic Systems and Control Conference (DSCC) · doi:10.1115/dscc2009-2644 · Cited by 90
Effect of an on-body ergonomic aid on oxygen consumption during a repetitive lifting task
Whitfield, B. H., Costigan, P. A., Stevenson, J. M., & Smallman, C. L. W. (2013) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2013.10.002 · Cited by 87
A Biomechanical Evaluation of Two Methods of Manual Load Lifting
Park, K. S., & Chaffin, D. B. (1974) · A I I E Transactions · doi:10.1080/05695557408974941 · Cited by 67
Design and Preliminary Evaluation of a Passive Spine Exoskeleton
Zhang, H., Kadrolkar, A., & Sup, F. C. (2015) · Journal of Medical Devices · doi:10.1115/1.4031798 · Cited by 48
Review on Lower Extremity Exoskeleton Robot
Li, N., Yan, L., Qian, H., Wu, H., Wu, J., & Men, S. (2015) · The Open Automation and Control Systems Journal · Cited by 35
Cited by
Kermavnar, T., de Vries, A. W., de Looze, M. P., & O’Sullivan, L. W. (2021) · Ergonomics · doi:10.1080/00140139.2020.1870162 · Cited by 275
Ojha, A., Gautam, Y., Jebelli, H., & Akanmu, A. (2024) · Automation in Construction · doi:10.1016/j.autcon.2024.105742 · Cited by 39
Metadata
- Authors
- Alemi, M. M., Geissinger, J., Simon, A. A., Chang, S. E., & Asbeck, A. T.
- Venue
- Journal of Electromyography and Kinesiology
- Publisher
- Elsevier BV
- Published
- 2019-08
- Volume
- 47
- Pages
- 25-34
- ISSN
- 1050-6411 (ISSN-L)
- OpenAlex
- W2942692510
- Cited by
- 189
- References
- 24
- FWCI
- 5.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.