Cited by 77Muscle activation and electromyography studiesMuscle Physiology and DisordersPeripheral Nerve Disorders

Consensus for experimental design in electromyography (CEDE) project: High-density surface electromyography matrix

Open access
Gallina, Alessio, Disselhorst-Klug, Catherine, Farina, Dario, Merletti, Roberto, Besomi, Manuela, Holobar, Aleš, Enoka, Roger M., Hug, François +13 more·2022·Journal of Electromyography and Kinesiology

Abstract

High-density surface electromyography (HDsEMG) can be used to measure the spatial distribution of electrical muscle activity over the skin. As this distribution is associated with the generation and propagation of muscle fiber action potentials, HDsEMG is processed to extract information on regional muscle activation, muscle fiber characteristics and behaviour of individual motor units. This matrix, developed by the Consensus for Experimental Design in Electromyography (CEDE) project, summarizes recommendations on the use of HDsEMG in experimental studies. For each application, recommendations are included regarding electrode montage, electrode type and configuration, electrode location and orientation, data analysis, and interpretation. Cautions and reporting standards are also included. The steps of the Delphi process to reach consensus are contained in an appendix. This matrix is intended to help researchers when collecting, reporting, and interpreting HDsEMG data. It is hoped that this document will be used to generate new empirical evidence to improve how HDsEMG is used in research and in clinical applications.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jelekin.2022.102656

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The frequency range of the input sine wave signals used in the performance tests (10-210 Hz) spans much of the relevant range of EEG, ECG, and EMG signals.

    “Hence, the frequency range of the input sine wave signals used in our performance tests spans much of the relevant range of these three common bioelectric signals.”

    From Comparison between Two Time Synchronization and Data Alignment Methods for Multi-Channel Wearable Biosensor Systems Using BLE Protocol (2023) · cites this paper as [38]

    The Sampling rate section gives an approximate 10–500 Hz bandwidth for high-density surface EMG, so the stated 10–210 Hz test range overlaps a substantial part of that range. Our copy does not establish the relevant frequency ranges for EEG or ECG, so it does not support the claim about all three signals. (LLM, conf=0.86)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

No references could be resolved yet.

Research works printed but not linked: 23

  1. 10.1016/j.jelekin.2004.09.003. · DOI
  2. Kleine, B. U. et al. (2007) 'Using two-dimensional spatial information in decomposition of surface EMG signals', Journal of Electromyography and Kinesiology, 17(5), pp. 535-548. doi: 10.1016/j.jelekin.2006.05.003. · DOI
  3. Lapatki, B. G. et al. (2005) 'Topographical Characteristics of Motor Units of the Lower Facial Musculature Revealed by Means of High-Density Surface EMG', Journal of Neurophysiology, 95(1), pp. 342-354. doi: 10.1152/jn.00265.2005. · DOI
  4. Lapatki, B. G. et al. (2011) 'Botulinum toxin has an increased effect when targeted toward the muscle's endplate zone: A high-density surface EMG guided study', Clinical Neurophysiology, 122(8), pp. 1611-1616. doi: 10.1016/j.clinph.2010.11.018. · DOI
  5. Madeleine, P. et al. (2006) 'Experimental muscle pain changes the spatial distribution of upper trapezius muscle activity during sustained contraction', Clinical Neurophysiology, 117(11), pp. 2436- 2445. doi: 10.1016/j.clinph.2006.06.753. · DOI
  6. Martinez-Valdes, E. et al. (2018) 'Surface electromyographic amplitude does not identify differences in neural drive to synergistic muscles', Journal of Applied Physiology, 124(4), pp. 1071-1079. doi: 10.1152/japplphysiol.01115.2017. · DOI
  7. Masuda, T., Miyano, H. and Sadoyama, T. (1983) 'The propagation of motor unit action potential and the location of neuromuscular junction investigated by surface electrode arrays', Electroencephalography and Clinical Neurophysiology, 55(5), pp. 594-600. doi: 10.1016/0013- 4694(83)90171-2. · DOI
  8. McManus, L. et al. (2021) 'Consensus for experimental design in electromyography (CEDE) project: Terminology matrix', Journal of Electromyography and Kinesiology, 59(May), p. 102565. doi: 10.1016/j.jelekin.2021.102565. · DOI
  9. Merletti, R. and Cerone, G. L. (2020) 'Tutorial. Surface EMG detection, conditioning and pre- processing: Best practices', Journal of Electromyography and Kinesiology, 54(June), p. 102440. doi: 10.1016/j.jelekin.2020.102440. · DOI · Paper page
  10. Merletti, R., Farina, D. and Gazzoni, M. (2003) 'The linear electrode array: A useful tool with many applications', Journal of Electromyography and Kinesiology, 13(1), pp. 37-47. doi: 10.1016/S1050- 6411(02)00082-2. · DOI · Paper page
  11. Merletti, R. and Muceli, S. (2019) 'Tutorial. Surface EMG detection in space and time: Best practices', Journal of Electromyography and Kinesiology, 49(August), p. 102363. doi: 10.1016/j.jelekin.2019.102363. · DOI
  12. Merletti, R., Rainoldi, A. and Farina, D. (2001) 'Surface electromyography for noninvasive characterization of muscle', Exercise & Sport Sciences Reviews, 29(1), pp. 20-25. Available at: http://articles.sirc.ca/search.cfm?id=S- 670978%0Ahttp://search.ebscohost.com/login.aspx?direct=true&db=s3h&AN=SPHS- 670978&site=ehost-live&scope=site%0Ahttp://www.acsm-essr.org.
  13. Mu, L. and Sanders, I. (2010) 'Sihler's whole mount nerve staining technique: A review', Biotechnic and Histochemistry, 85(1), pp. 19-42. doi: 10.3109/10520290903048384. · DOI
  14. Rodriguez-Falces, J. et al. (2013) 'Spatial distribution of surface action potentials generated by individual motor units in the human biceps brachii muscle', Journal of Electromyography and Kinesiology, 23(4), pp. 766-777. doi: 10.1016/j.jelekin.2013.03.011. · DOI
  15. Roeleveld, K. et al. (1997) 'The motor unit potential distribution over the skin surface and its use in estimating the motor unit location', Acta Physiologica Scandinavica, 161(4), pp. 465-472. doi: 10.1046/j.1365-201X.1997.00247.x. · DOI
  16. Schulte, E. et al. (2005) 'Estimation of the muscle fibre semi-length under varying joint positions on the basis of non-invasively extracted motor unit action potentials', Journal of Electromyography and Kinesiology, 15(3), pp. 290-299. doi: 10.1016/j.jelekin.2004.10.006. · DOI
  17. Del Vecchio, A. et al. (2020) 'Tutorial: Analysis of motor unit discharge characteristics from high- density surface EMG signals', Journal of Electromyography and Kinesiology, 53, p. 102426. doi: 10.1016/j.jelekin.2020.102426. · DOI
  18. Vieira, T. M. et al. (2019) 'Postural muscle unit plasticity in stroke survivors: Altered distribution of gastrocnemius' action potentials', Frontiers in Neurology, 10(JUN), pp. 1-10. doi: 10.3389/fneur.2019.00686. · DOI
  19. Vieira, T. M. M. et al. (2011) 'Postural activation of the human medial gastrocnemius muscle: Are the muscle units spatially localised?', Journal of Physiology, 589(2), pp. 431-443. doi: 10.1113/jphysiol.2010.201806. · DOI
  20. Waggoner, J., Carline, J. D. and Durning, S. J. (2016) 'Is there a consensus on consensus methodology? Descriptions and recommendations for future consensus research', Academic Medicine, 91(5), pp. 663- 668. doi: 10.1097/ACM.0000000000001092. · DOI
  21. Watanabe, K., Kouzaki, M. and Moritani, T. (2012) 'Task-dependent spatial distribution of neural activation pattern in human rectus femoris muscle', Journal of Electromyography and Kinesiology, 22(2), pp. 251-258. doi: 10.1016/j.jelekin.2011.11.004. · DOI
  22. Zhou, P., Suresh, N. L. and Rymer, W. Z. (2011) 'Surface electromyogram analysis of the direction of isometric torque generation by the first dorsal interosseous muscle', Journal of Neural Engineering, 8(3). doi: 10.1088/1741-2560/8/3/036028. · DOI
  23. Zwarts, M. J. and Stegeman, D. F. (2003) 'Multichannel surface EMG: Basic aspects and clinical utility', Muscle and Nerve, 28(1), pp. 1-17. doi: 10.1002/mus.10358. · DOI · Paper page

Cited by

Sorted by citations

Authors
Gallina, A., Disselhorst-Klug, C., Farina, D., Merletti, R., Besomi, M., Holobar, A., Enoka, R. M., Hug, F., Falla, D., Søgaard, K., McGill, K., Clancy, E. A., Carson, R. G., van Dieën, J. H., Gandevia, S., Lowery, M., Besier, T., Kiernan, M. C., Rothwell, J. C., Tucker, K., & Hodges, P. W.
Affiliations
  • University of Birmingham (GB)
  • RWTH Aachen University (DE)
  • Imperial College London (GB)
  • Politecnico di Torino (IT)
  • The University of Queensland (AU)
  • University of Maribor (SI)
  • University of Colorado Boulder (US)
  • University of Southern Denmark (DK)
  • United States Department of Veterans Affairs (US)
  • Worcester Polytechnic Institute (US)
  • Queen's University Belfast (GB)
  • UNSW Sydney (AU)
  • University College Dublin (IE)
  • University of Auckland (NZ)
  • The University of Sydney (AU)
  • UCL Queen Square Institute of Neurology (GB)
Corresponding author
Hodges, Paul W.
Venue
Journal of Electromyography and Kinesiology
Publisher
Elsevier BV
Published
2022-06
Volume
64
Pages
102656
ISSN
1050-6411 (ISSN-L)
OpenAlex
W4220763389
Cited by
77
References
0
Citations by year
2026: 20 · 2025: 22 · 2024: 15 · 2023: 16 · 2022: 4
FWCI
4.14
Type
journal article
Language
en
Open access
Locations
  • Journal of Electromyography and Kinesiology (publishedVersion)
  • PubMed (publishedVersion)
  • VU Research Portal (publishedVersion, other-oa)
  • UNSWorks (University of New South Wales, Sydney, Australia) (submittedVersion, cc-by-nc-nd)
  • HAL (submittedVersion, cc-by-nc-nd)
  • RWTH Publications (RWTH Aachen) (submittedVersion)
  • University of Birmingham Research Portal (University of Birmingham) (submittedVersion, cc-by-nc-nd)
  • Research Portal (Queen's University Belfast) (submittedVersion)
  • University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
Funders
  • Royal Society
  • Javna Agencija za Raziskovalno Dejavnost RS (P2-0041, L7-9421, J2-1731, Program funding P2-0041, projects J2-1731)
  • Institut Universitaire de France
  • National Health and Medical Research Council (1102905, 1132524, 1153439)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Peripheral Nerve Disorders
Keywords
high-density surface electromyography, electrode montage, electrode configuration, muscle activation, motor unit behavior, muscle fiber action potentials, Delphi consensus, reporting guidelines
MeSH terms
Electrodes, Electromyography, Humans, Research Design, Muscle, Skeletal, Consensus

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review