CoChat

The Feasibility and Accuracy of Point-of-Care Lactate Measurement in Emergency Department Patients with Suspected Infection

Open access
Shapiro, Nathan I., Fisher, Christopher, Donnino, Michael, Cataldo, Lauren, Tang, Aimee, Trzeciak, Stephen, Horowitz, Gary, Wolfe, Richard E. · 2010 · The Journal of Emergency Medicine
Cited by 70

The DOI matches its Crossref record.

Abstract

Background Prior studies show that lactate is a useful prognostic marker in sepsis. Objective To study the feasibility and accuracy of a point-of-care (POC) analyzer capable of performing bedside serum lactate measurements; and to determine if other measurements (pH, base excess) are predictive of mortality. Methods: Design: prospective cohort study of adult (age 18 years or older) Emergency Department (ED) patients with suspected infection during the study period of May 2006 through March 2007. Setting A 55,000-annual-visit urban tertiary care ED. Intervention A point-of-care device (i-STAT, Abbott Point of Care Inc., Princeton, NJ) was deployed using a standardized training and quality assurance process. Using POC testing, we measured serum lactate, pH, and base excess, as well as concomitant lactate measurement via a central laboratory. Statistics Area under the curve (AUC) for receiver operator characteristic curve, Bland-Altman statistics along with a correlation coefficient, and relative risk with 95% confidence intervals reported. Results There were 699 patients enrolled, of whom 34 (4.9%) died. The AUCs for mortality prediction were: POC lactate 0.72, laboratory lactate 0.70, pH measurement 0.60, and base excess 0.60. Bland-Altman showed that POC lactate was, on average, 0.32 (95% confidence interval −0.35– 0.98) lower than laboratory lactate, with agreement kappa = 0.97. Conclusions A point-of-care testing device provides a reliable and feasible way to measure serum lactate at the bedside. The pH and base excess were less helpful.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jemermed.2009.07.021

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 70

Metadata

Authors
Shapiro, N. I., Fisher, C., Donnino, M., Cataldo, L., Tang, A., Trzeciak, S., Horowitz, G., & Wolfe, R. E.
Venue
The Journal of Emergency Medicine
Publisher
Elsevier BV
Published
2010-07
Volume
39
Issue
1
Pages
89-94
ISSN
0736-4679 (ISSN-L)
OpenAlex
W2142123151
Cited by
70
References
0
FWCI
3.29
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Feasibility and Accuracy of Point-of-Care Lactate Measurement in Emergency Department Patients with Suspected Infection. https://app.cochat.ai/papers/10.1016/j.jemermed.2009.07.021
The paper
Shapiro, N. I., Fisher, C., Donnino, M., Cataldo, L., Tang, A., Trzeciak, S., Horowitz, G., & Wolfe, R. E. (2010). The Feasibility and Accuracy of Point-of-Care Lactate Measurement in Emergency Department Patients with Suspected Infection. The Journal of Emergency Medicine. https://doi.org/10.1016/j.jemermed.2009.07.021

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.