Sorption of copper(II) onto super-adsorbent of bentonite–polyacrylamide composites
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
In this work, bentonite embedded in the polyacrylamide (PAAm) gels was used as a novel adsorbent for the removal of Cu(II) from aqueous solution. The sorption and desorption of Cu(II) on bentonite-polyacrylamide (BENT-PAAm) was investigated as the function of pH, ionic strength, adsorbent content, Cu(II) concentrations and temperature. The results indicated that the sorption of Cu(II) on BENT-PAAm was strongly dependent on pH, ionic strength and temperature. The sorption increased from about 9% to 97% at pH ranging from 2.4 to 7. The sorption of Cu(II) on BENT-PAAm increased with increasing temperature and decreasing ionic strength. The sorption of Cu(II) on BENT and on BENT-PAAm was an endothermic and irreversible process. The results of desorption indicated that the adsorbed Cu(II) ions on solid particles were difficult to be desorbed from solid to liquid phase. From the comparison with BENT, BENT-PAAm showed higher sorption capacity with C(smax) increasing from 29 to 33 mg/g at pH 6.2 and from 11 to 20mg/g at pH 5.0 for the sorption of Cu(II) from BENT to BENT-PAAm composites. The average standard enthalpy change (Delta H degrees) and the entropy change (DeltaS degrees ) of Cu(II) sorption on BENT-PAAm are higher than those of Cu(II) sorption on BENT. The BENT-PAAm composites can be used as a super-adsorbent for the removal of Cu(II) from aqueous solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The adsorption of gases on plane surfaces of glass, mica and platinum
Langmuir, I. (1918) · Journal of the American Chemical Society · doi:10.1021/ja02242a004 · Cited by 23,242
Dubinin, M. M. (1960) · Chemical Reviews · doi:10.1021/cr60204a006 · Cited by 2,405
Da̧browski, A., Hubicki, Z., Podkościelny, P., & Robens, E. (2004) · Chemosphere · doi:10.1016/j.chemosphere.2004.03.006 · Cited by 1,717 · cited 1×
“Up to now, there are various technologies for removing heavy metal ions from solution, including filtration, surface complexation, chemical precipitation, ion exchange, adsorption, electrode position, and membrane processing [2–5].”
Özcan, A., Öncü, E. M., & Özcan, A. S. (2006) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2005.11.017 · Cited by 466
Yang, S., Li, J., Shao, D., Hu, J., & Wang, X. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.11.003 · Cited by 446
Self-citationAdsorption of Arsenic from Water Using Activated Neutralized Red Mud
Genç-Fuhrman, H., Tjell, J. C., & McConchie, D. (2004) · Environmental Science & Technology · doi:10.1021/es035207h · Cited by 375 · cited 1×
“The positive values of entropy change ( S◦) reflected the affinity of Cu(II) ions on BENT and on BENT–PAAm, suggesting some structure changes in adsorbents [24,25].”
BackgroundArsenic removal from aqueous solutions by adsorption on red mud
Soner Altundoğan, H., Altundoğan, S., Tümen, F., & Bildik, M. (2000) · Waste Management · doi:10.1016/s0956-053x(00)00031-3 · Cited by 366 · cited 1×
“The positive values of entropy change ( S◦) reflected the affinity of Cu(II) ions on BENT and on BENT–PAAm, suggesting some structure changes in adsorbents [24,25].”
BackgroundXU, D. (2008) · Applied Clay Science · doi:10.1016/j.clay.2007.09.004 · Cited by 300
A comparative study of the adsorption and desorption of o-xylene onto bentonite clay and alumina
Zaitan, H., Bianchi, D., Achak, O., & Chafik, T. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.09.070 · Cited by 219
Removal of heavy metal ions from water by complexation-assisted ultrafiltration
Trivunac, K., & Stevanovic, S. (2006) · Chemosphere · doi:10.1016/j.chemosphere.2005.11.073 · Cited by 214 · cited 1×
“Up to now, there are various technologies for removing heavy metal ions from solution, including filtration, surface complexation, chemical precipitation, ion exchange, adsorption, electrode position, and membrane processing [2–5].”
Cited by
A review on the adsorption of heavy metals by clay minerals, with special focus on the past decade
Uddin, M. K. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.09.029 · Cited by 2,108
Kinetics of adsorption of metal ions on inorganic materials: A review
Sen Gupta, S., & Bhattacharyya, K. G. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.12.004 · Cited by 901
Liu, X., Pang, H., Liu, X., Li, Q., Zhang, N., Mao, L., Qiu, M., Hu, B., Yang, H., & Wang, X. (2021) · The Innovation · doi:10.1016/j.xinn.2021.100076 · Cited by 603
Self-citationBadruddoza, A. Z. M., Tay, A. S. H., Tan, P. Y., Hidajat, K., & Uddin, M. S. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.10.029 · Cited by 572
Kumar, S., Prasad, S., Yadav, K. K., Shrivastava, M., Gupta, N., Nagar, S., Bach, Q.-V., Kamyab, H., Khan, S. A., Yadav, S., et al. (2019) · Environmental Research · doi:10.1016/j.envres.2019.108792 · Cited by 560
RetractedGuo, X., Du, B., Wei, Q., Yang, J., Hu, L., Yan, L., & Xu, W. (2014) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2014.05.075 · Cited by 555
Polymer-based nanocomposites for heavy metal ions removal from aqueous solution: a review
Zhao, G., Huang, X., Tang, Z., Huang, Q., Niu, F., & Wang, X. (2018) · Polymer Chemistry · doi:10.1039/c8py00484f · Cited by 531
Self-citationRemoval of Cu(II) and Fulvic Acid by Graphene Oxide Nanosheets Decorated with Fe3O4 Nanoparticles
Li, J., Zhang, S., Chen, C., Zhao, G., Yang, X., Li, J., & Wang, X. (2012) · ACS Applied Materials & Interfaces · doi:10.1021/am301358b · Cited by 516
Self-citationLiu, X., Ma, R., Wang, X., Ma, Y., Yang, Y., Zhuang, L., Zhang, S., Jehan, R., Chen, J., & Wang, X. (2019) · Environmental Pollution · doi:10.1016/j.envpol.2019.05.050 · Cited by 511
Self-citationSynthesis of Magnetite/Graphene Oxide Composite and Application for Cobalt(II) Removal
Liu, M., Chen, C., Hu, J., Wu, X., & Wang, X. (2011) · The Journal of Physical Chemistry C · doi:10.1021/jp208575m · Cited by 452
Self-citationApplication of graphitic carbon nitride for the removal of Pb(II) and aniline from aqueous solutions
Hu, R., Wang, X., Dai, S., Shao, D., Hayat, T., & Alsaedi, A. (2015) · Chemical Engineering Journal · doi:10.1016/j.cej.2014.09.013 · Cited by 390
Self-citationSamiey, B., Cheng, C.-H., & Wu, J. (2014) · Materials · doi:10.3390/ma7020673 · Cited by 368
Clay based nanocomposites for removal of heavy metals from water: A review
Yadav, V. B., Gadi, R., & Kalra, S. (2019) · Journal of Environmental Management · doi:10.1016/j.jenvman.2018.11.120 · Cited by 344
Srinivasan, R. (2011) · Advances in Materials Science and Engineering · doi:10.1155/2011/872531 · Cited by 315
Adsorption of heavy metals on kaolinite and montmorillonite: a review
Sen Gupta, S., & Bhattacharyya, K. G. (2012) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp40093f · Cited by 315
Study on the adsorption of Cu(II) by EDTA functionalized Fe3O4 magnetic nano-particles
Liu, Y., Chen, M., & Yongmei, H. (2013) · Chemical Engineering Journal · doi:10.1016/j.cej.2012.12.027 · Cited by 292
Barakan, S., & Aghazadeh, V. (2021) · Environmental Science and Pollution Research · doi:10.1007/s11356-020-10985-9 · Cited by 255
Mushtaq, M., Bhatti, H. N., Iqbal, M., & Noreen, S. (2016) · Journal of Environmental Management · doi:10.1016/j.jenvman.2016.03.013 · Cited by 234
Zou, Y., Wang, X., Ai, Y., Liu, Y., Ji, Y., Wang, H., Hayat, T., Alsaedi, A., Hu, W., & Wang, X. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta05958a · Cited by 217
Self-citationDa’na, E., & Sayari, A. (2011) · Chemical Engineering Journal · doi:10.1016/j.cej.2010.11.016 · Cited by 200
A review on functional polymer-clay based nanocomposite membranes for treatment of water
Buruga, K., Song, H., Shang, J., Bolan, N., Jagannathan, T. K., & Kim, K.-H. (2019) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.04.067 · Cited by 188
Adsorption thermodynamics to clean up wastewater; critical review
Doke, K. M., & Khan, E. M. (2013) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-012-9273-z · Cited by 187
Song, W., Wang, X., Wang, Q., Shao, D., & Wang, X. (2015) · Physical Chemistry Chemical Physics · doi:10.1039/c4cp04289a · Cited by 165
Self-citationSurface-modified magnetic biochar: Highly efficient adsorbents for removal of Pb (ΙΙ) and Cd (ΙΙ)
Zahedifar, M., Seyedi, N., Shafiei, S., & Basij, M. (2021) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2021.124860 · Cited by 97
Metadata
- Authors
- Zhao, G., Zhang, H., Fan, Q., Ren, X., Li, J., Chen, Y., & Wang, X.
- Venue
- Journal of Hazardous Materials
- Publisher
- Elsevier BV
- Published
- 2010-01-15
- Volume
- 173
- Issue
- 1-3
- Pages
- 661-668
- ISSN
- 0304-3894 (ISSN-L)
- OpenAlex
- W1974601538
- Cited by
- 246
- References
- 15
- FWCI
- 22.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.