Sorption of copper(II) onto super-adsorbent of bentonite–polyacrylamide composites
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this work, bentonite embedded in the polyacrylamide (PAAm) gels was used as a novel adsorbent for the removal of Cu(II) from aqueous solution. The sorption and desorption of Cu(II) on bentonite-polyacrylamide (BENT-PAAm) was investigated as the function of pH, ionic strength, adsorbent content, Cu(II) concentrations and temperature. The results indicated that the sorption of Cu(II) on BENT-PAAm was strongly dependent on pH, ionic strength and temperature. The sorption increased from about 9% to 97% at pH ranging from 2.4 to 7. The sorption of Cu(II) on BENT-PAAm increased with increasing temperature and decreasing ionic strength. The sorption of Cu(II) on BENT and on BENT-PAAm was an endothermic and irreversible process. The results of desorption indicated that the adsorbed Cu(II) ions on solid particles were difficult to be desorbed from solid to liquid phase. From the comparison with BENT, BENT-PAAm showed higher sorption capacity with C(smax) increasing from 29 to 33 mg/g at pH 6.2 and from 11 to 20mg/g at pH 5.0 for the sorption of Cu(II) from BENT to BENT-PAAm composites. The average standard enthalpy change (Delta H degrees) and the entropy change (DeltaS degrees ) of Cu(II) sorption on BENT-PAAm are higher than those of Cu(II) sorption on BENT. The BENT-PAAm composites can be used as a super-adsorbent for the removal of Cu(II) from aqueous solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The adsorption of gases on plane surfaces of glass, mica and platinum
Langmuir, I. (1918) · Journal of the American Chemical Society · doi:10.1021/ja02242a004 · Cited by 23,242
Da̧browski, A., Hubicki, Z., Podkościelny, P., & Robens, E. (2004) · Chemosphere · doi:10.1016/j.chemosphere.2004.03.006 · Cited by 1,717 · cited 1×
“Up to now, there are various technologies for removing heavy metal ions from solution, including filtration, surface complexation, chemical precipitation, ion exchange, adsorption, electrode position, and membrane processing [2–5].”
Cited by
A review on the adsorption of heavy metals by clay minerals, with special focus on the past decade
Uddin, M. K. (2017) · Chemical Engineering Journal · doi:10.1016/j.cej.2016.09.029 · Cited by 2,108
Kinetics of adsorption of metal ions on inorganic materials: A review
Sen Gupta, S., & Bhattacharyya, K. G. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.12.004 · Cited by 901
Liu, X., Pang, H., Liu, X., Li, Q., Zhang, N., Mao, L., Qiu, M., Hu, B., Yang, H., & Wang, X. (2021) · The Innovation · doi:10.1016/j.xinn.2021.100076 · Cited by 603
Self-citationBadruddoza, A. Z. M., Tay, A. S. H., Tan, P. Y., Hidajat, K., & Uddin, M. S. (2011) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.10.029 · Cited by 572
Kumar, S., Prasad, S., Yadav, K. K., Shrivastava, M., Gupta, N., Nagar, S., Bach, Q.-V., Kamyab, H., Khan, S. A., Yadav, S., et al. (2019) · Environmental Research · doi:10.1016/j.envres.2019.108792 · Cited by 560
Retracted
Metadata
- Authors
- Zhao, G., Zhang, H., Fan, Q., Ren, X., Li, J., Chen, Y., & Wang, X.
- Venue
- Journal of Hazardous Materials
- Publisher
- Elsevier BV
- Published
- 2010-01-15
- Volume
- 173
- Issue
- 1-3
- Pages
- 661-668
- ISSN
- 0304-3894 (ISSN-L)
- OpenAlex
- W1974601538
- Cited by
- 246
- References
- 2
- FWCI
- 22.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.