A fast response & recovery H2S gas sensor based on α-Fe2O3 nanoparticles with ppb level detection limit
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toward innovations of gas sensor technology
Yamazoe, N. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.12.075 · Cited by 1,292
The effects of thickness and operation temperature on ZnO:Al thin film CO gas sensor
Chang, J. F., Kuo, H.-Y., Leu, I., & Hon, M. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(02)00034-5 · Cited by 571
Air pollution and daily mortality: Associations with particulates and acid aerosols
Dockery, D. W., Schwartz, J., & Spengler, J. D. (1992) · Environmental Research · doi:10.1016/s0013-9351(05)80042-8 · Cited by 568
Sun, Z., Yuan, H., Liu, Z., Han, B., & Zhang, X. (2005) · Advanced Materials · doi:10.1002/adma.200501562 · Cited by 452
Semiconducting Metal Oxide Based Sensors for Selective Gas Pollutant Detection
Kanan, S. M., El-Kadri, O. M., Abu-Yousef, I. A., & Kanan, M. C. (2009) · Sensors · doi:10.3390/s91008158 · Cited by 447
Sub-ppm H2S sensing at room temperature using CuO thin films
Ramgir, N. S., Ganapathi, S. K., Kaur, M., Datta, N., Muthe, K. P., Aswal, D. K., Gupta, S. K., & Yakhmi, J. V. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.09.043 · Cited by 221
Li, Z., Shen, W., He, W., & Zu, X. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.11.095 · Cited by 213
Self-citationHighly sensitive ZnO nanowire CO sensors with the adsorption of Au nanoparticles
Chang, S.-J., Hsueh, T.-J., Chen, I.-C., & Huang, B.-R. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/17/175502 · Cited by 206
Hollow SnO 2 /α-Fe 2 O 3 spheres with a double-shell structure for gas sensors
Sun, P., Zhou, X., Wang, C., Shimanoe, K., Lu, G., & Yamazoe, N. (2014) · Journal of Materials Chemistry A · doi:10.1039/c3ta13707d · Cited by 155
Present technologies for hydrogen sulfide removal from gaseous mixtures
Wiheeb, A. D., Shamsudin, I. K., Ahmad, M. A., Murat, M. N., Kim, J., & Othman, M. R. (2013) · Reviews in Chemical Engineering · doi:10.1515/revce-2013-0017 · Cited by 150
Hosseini, Z. S., Mortezaali, A., zad, A. I., & Fardindoost, S. (2015) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2014.12.163 · Cited by 145
A high performance hydrogen sulfide gas sensor based on porous α-Fe2O3 operates at room-temperature
Huang, Y., Chen, W., Zhang, S., Kuang, Z., Ao, D., Alkurd, N., Zhou, W. L., Liu, W., Shen, W., & Li, Z. (2015) · Applied Surface Science · doi:10.1016/j.apsusc.2015.06.053 · Cited by 133
Self-citationFacile Fabrication of a Well-Ordered Porous Cu-Doped SnO 2 Thin Film for H 2 S Sensing
Zhang, S., Zhang, P., Wang, Y., Ma, Y., Zhong, J., & Sun, X. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am502671s · Cited by 129
Self-citationExcellent Toluene Sensing Properties of SnO2–Fe2O3 Interconnected Nanotubes
Shan, H., Liu, C.-B., Liu, L. M., Zhang, J., Li, H., Liu, Z., Zhang, X., Bo, X., & Chi, X. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am4015082 · Cited by 116
Liao, L., Zheng, Z., Yan, B., Zhang, J. X., Gong, H., Li, J. C., Liu, C., Shen, Z., & Yu, T. (2008) · The Journal of Physical Chemistry C · doi:10.1021/jp802968a · Cited by 98
Deng, J., Ma, J., Mei, L., Tang, Y., Chen, Y., Lv, T., Xu, Z. Q., & Wang, T. (2013) · Journal of Materials Chemistry A · doi:10.1039/c3ta12253k · Cited by 94
Grain growth and stabilisation of nanostructured aluminium at high temperatures: Review
Asgharzadeh, H., & McQueen, H. J. (2014) · Materials Science and Technology · doi:10.1179/1743284714y.0000000706 · Cited by 54
Electrochemical H2S sensor with H2SO4 pre-treated Nafion membrane as solid polymer electrolyte
Yu, C. Y. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(02)00200-9 · Cited by 51
Yao, K., Caruntu, D., Zeng, Z., Chen, J., O’Connor, C. J., & Zhou, W. L. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp905189f · Cited by 51
An optical sensor for monitoring of dissolved oxygen based on phase detection
Feng, W., Zhou, N., Chen, L., & Li, B. (2013) · Journal of Optics · doi:10.1088/2040-8978/15/5/055502 · Cited by 30
Rassaei, L., Herrmann, M., Gordeev, S. N., & Marken, F. (2012) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2012.09.022 · Cited by 6
Cited by
Metal oxide nanoparticles and their applications in nanotechnology
Chavali, M. S., & Nikolova, M. P. (2019) · SN Applied Sciences · doi:10.1007/s42452-019-0592-3 · Cited by 1,133
Li, Z., Li, H., Wu, Z., Wang, M., Luo, J., Torun, H., Hu, P., Yang, C., Grundmann, M., Liu, X., et al. (2019) · Materials Horizons · doi:10.1039/c8mh01365a · Cited by 760
Self-citationRecent Advances in Electrochemical Sensors for Detecting Toxic Gases: NO2, SO2 and H2S
Khan, M. A. H., Rao, M. V., & Li, Q. (2019) · Sensors · doi:10.3390/s19040905 · Cited by 417
Metal-Oxide Nanomaterials Synthesis and Applications in Flexible and Wearable Sensors
Yoon, Y., Truong, P. L., Lee, D., & Ko, S. H. (2022) · ACS Nanoscience Au · doi:10.1021/acsnanoscienceau.1c00029 · Cited by 313
Li, Z., Wang, N., Lin, Z., Wang, J., Liu, W., Sun, K., Fu, Y. Q., & Wang, Z. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b02893 · Cited by 270
Self-citation
Metadata
- Authors
- Li, Z., Huang, Y., Zhang, S., Chen, W., Kuang, Z., Ao, D., Liu, W., & Fu, Y.
- Venue
- Journal of Hazardous Materials
- Publisher
- Elsevier BV
- Published
- 2015-12
- Volume
- 300
- Pages
- 167-174
- ISSN
- 0304-3894 (ISSN-L)
- OpenAlex
- W1997035228
- Cited by
- 265
- References
- 21
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.