The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Ultralight, highly compressible, hydrophobic and anisotropic lamellar carbon aerogels from graphene/polyvinyl alcohol/cellulose nanofiber aerogel as oil removing absorbents
Abstract
In increasingly serious marine pollution environment, environmentally friendly low-density aerogels have become potential oil-water separation materials. However, many reported aerogels have the drawbacks of low oil absorption, poor compressibility and flexibility, which limit their application. Herein, we reported a compressible, anisotropic lamellar hydrophobic and lipophilic graphene/polyvinyl alcohol/cellulose nanofiber carbon aerogel (a-GPCCA) prepared by directional freeze-drying and carbonization processes. The synthetic ultralight a-GPCCA had low density (6.17 mg/cm3) and high porosity (99.61 %). Moreover, directional freeze-drying resulted in a lamellar interpenetrated three-dimensional porous structure, which endowed it with high adsorption capacity (155-288 times of its weight), good compressibility (95 % recovery after repeating 15 cycles at 50 % strain in parallel to the freezing direction) and recyclability (oil retention rate reached 88.8 % after 10 absorption-compression cycles). Furthermore, carbonization provided it with excellent thermal stability and hydrophobic properties, resulting in oil-water selectivity and combustion cyclicity (the oil absorption capacity was reduced by only 10.2 % after 10 absorption-combustion cycles). Therefore, the a-GPCCA obtained in this study possesses a promising potential in the field of treatment of offshore oil spills and domestic industrial wastewater.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Freeze‐Casting of Porous Ceramics: A Review of Current Achievements and Issues
Deville, S. (2008) · Advanced Engineering Materials · doi:10.1002/adem.200700270 · Cited by 1,260
Bi, H., Yin, Z., Cao, X., Xie, X., Tan, C., Huang, X., Chen, B., Chen, F., Yang, Q., Bu, X., et al. (2013) · Advanced Materials · doi:10.1002/adma.201302435 · Cited by 667
Zhang, Y., Fan, W., Huang, Y., Zhang, C., & Liu, T. (2015) · RSC Advances · doi:10.1039/c4ra13015d · Cited by 112
Cited by
Chen, Y., Zhang, L., Yang, Y., Pang, B., Xu, W., Duan, G., Jiang, S., & Zhang, K. (2021) · Advanced Materials · doi:10.1002/adma.202005569 · Cited by 721
Ultralight NiCo@rGO aerogel microspheres with magnetic response for oil/water separation
Cheng, Y., Cai, Y., Wang, Z., Lu, X., & Xia, H. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.132894 · Cited by 45
Metadata
- Authors
- Zhou, L., & Xu, Z.
- Venue
- Journal of Hazardous Materials
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 388
- Pages
- 121804
- ISSN
- 0304-3894 (ISSN-L)
- OpenAlex
- W2993096652
- Cited by
- 229
- References
- 3
- FWCI
- 6.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultralight, highly compressible, hydrophobic and anisotropic lamellar carbon aerogels from graphene/polyvinyl alcohol/cellulose nanofiber aerogel as oil removing absorbents. https://app.cochat.ai/papers/10.1016/j.jhazmat.2019.121804
- The paper
- Zhou, L., & Xu, Z. (2020). Ultralight, highly compressible, hydrophobic and anisotropic lamellar carbon aerogels from graphene/polyvinyl alcohol/cellulose nanofiber aerogel as oil removing absorbents. Journal of Hazardous Materials. https://doi.org/10.1016/j.jhazmat.2019.121804
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.