Cited by 245Gas Sensing Nanomaterials and SensorsZnO doping and propertiesCatalytic Processes in Materials Science

Plasma-induced oxygen vacancies enabled ultrathin ZnO films for highly sensitive detection of triethylamine

Li, Zishuo, Liu, Xianghong, Zhou, Miao, Zhang, Shoulong, Cao, Shize, Lei, Guanglu, Lou, Chengming, Zhang, Jun·2021·Journal of Hazardous Materials

Abstract

Metal oxide semiconductor (MOS) thin films hold great promise for electronic devices such as gas sensors. However, the low surface activity of pristine MOS often leads to inferior sensitivity and the sensitization mechanism of ultrathin MOS films has received rare attention. Herein, we report a high performance gas sensor based on plasma-etched ZnO thin films. The ultrathin ZnO films (20 nm) were deposited on SiO 2 wafers by atomic layer deposition (ALD), which enables high-throughput production of sensor devices. The ZnO sensor shows typical n-type conductivity, which is highly variable to the exposure of triethylamine (TEA). Annealing temperature of the films is found to impact the sensor response, revealing calcination at a moderate temperature, i.e. 700 °C, leads to the best response. Further treatment by Ar plasma results in a remarkable decrease of sensor working temperature from 300 °C of untreated films to 250 °C and nearly 4-fold enhancement in the sensor response to 10 ppm TEA. Notably, the plasma-treated ZnO sensor also shows decent response even at room temperature (RT), which has been seldom reported for ZnO-based sensors. Structure and mechanism investigations reveal that the superior sensor properties are derived from the abundant oxygen vacancies generated by Ar plasma etching.

Integrity signals

Registry

Crossref · 10.1016/j.jhazmat.2021.125757

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Widely studied metal-oxide semiconductor vapor sensors require high temperatures to ensure sensing operation, contrary to wearable device operation.

    “widely studied metal–oxide semiconductor vapor sensors require high temperatures to ensure the sensing operation of their sensitive material, which is contrary to the operation of wearable devices”

Cited by

Sorted by citations

Authors
Li, Z., Liu, X., Zhou, M., Zhang, S., Cao, S., Lei, G., Lou, C., & Zhang, J.
Affiliations
Qingdao University (CN)
Corresponding author
  • Liu, Xianghong
  • Zhang, Jun
Venue
Journal of Hazardous Materials
Publisher
Elsevier BV
Published
2021-08
Volume
415
Pages
125757
ISSN
0304-3894 (ISSN-L)
OpenAlex
W3142403770
Cited by
245
References
0
Citations by year
2026: 19 · 2025: 44 · 2024: 45 · 2023: 53 · 2022: 49 · 2021: 35
FWCI
13.14
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Hazardous Materials (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Natural Science Foundation of Shandong Province (ZR2020JQ27)
  • National Natural Science Foundation of China (61971252, 51972182)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Materials Science › Materials Chemistry › ZnO doping and properties
  • Physical Sciences › Materials Science › Materials Chemistry › Catalytic Processes in Materials Science
Keywords
ZnO thin films, oxygen vacancies, triethylamine detection, gas sensors, plasma etching, Ar plasma treatment, calcination temperature, room-temperature gas sensing, n-type conductivity, atomic layer deposition

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review