CoChat

Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.

Open access

The DOI matches its Crossref record; 286 of the 289 references it cites were found in a registry or an index; 74 of the 284 sources its claims cite were checked for support.

Abstract

Functionalized hydrogels are intrinsically conductive, self-healing, self-adhesive, biocompatible, and room-temperature sensitive.

Overview

CoChat Summary

TL;DR

This review summarizes how hydrogel properties are optimized for wearable gas and humidity sensors, and how these devices work for monitoring gases such as NO2, NH3, O2, CO2, and explosives, as well as humidity. It argues that hydrogels are promising because they can be stretchable, conductive, self-healing, and room-temperature operable, but the field is still in its early stages.

Key findings

  • Hydrogels can be engineered for wearable sensing by improving mechanical deformability, conductivity, anti-freezing/water retention, self-healing, biocompatibility, self-adhesion, and transparency.
  • For gas sensing, the review highlights reported examples with specific performance values, including NO2 detection limits as low as 4.1 ppb, 1.2 ppb, 0.1 ppb, and 2.23 ppb; NH3 detection limits as low as 0.42 ppm, 0.07 ppm, 0.5 ppm, 50 ppb, and 92 ppb; O2 detection limit as low as 5.7 ppm; and CO2 detection limit of 20 ppm in one hydrogel sensor example.
  • For humidity sensing, hydrogels show strong swelling-based and conductivity-based responses, with reported sensitivities including 13,462.1% RH%−1, 78,785.5% RH%−1, and 25,000 to 98% RH operation in one sensor example.
  • The review says hydrogel-based wearable sensors have been used for environmental monitoring, healthcare, respiratory monitoring, electronic skin, and wireless monitoring, but still need better selectivity, stability, standardization, and integration.

Methods

  • This is a review article, not an experimental study; it systematically summarizes published work on functionalized hydrogel-based wearable gas and humidity sensors.
  • The paper organizes the literature by hydrogel design/optimization and by application area: gas sensing, humidity sensing, and wearable use cases such as respiratory monitoring and e-skin.
  • Its synthesis is based on reported studies and their performance parameters, with tables and example devices used to compare sensing mechanisms and outcomes.

Limitations

  • The paper explicitly states that research on hydrogel-based vapor sensors is still in its infancy and that many practical problems remain.
  • It says the gas- and humidity-sensing mechanisms are not yet unified or fully understood, and that factors such as electrode properties, crosslinking method, crosslinking density, and conductivity need further study.
  • It notes that most gas-sensor work focuses on NO2, NH3, and O2, so other gases still need exploration.
  • Evident from the text: this is a narrative review rather than a systematic meta-analysis, so its comparisons are descriptive and depend on the cited studies rather than a standardized pooled evaluation.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1007/s40820-023-01109-2

Cites

286 of 286 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Schematic of the functionalized hydrogel-based vapor sensors for personal health and safety monitoring
Fig. 1 Schematic of the functionalized hydrogel-based vapor sensors for personal health and safety monitoringCC BY · PubMed Central
Fig. 2 a Schematic of the synthesis of tetra-PEG hydrogel. Reproduced with permission [111]. Copyright 2008, American Chemical Society. b Schematic of the synthesis of DN hydrogels. c Schematic diagram of the synthesis of clay NPs/PNIPAMNC. Reproduced with permission [112]. Copyright 2002, Wiley‐VCH
Fig. 2 a Schematic of the synthesis of tetra-PEG hydrogel. Reproduced with permission [111]. Copyright 2008, American Chemical Society. b Schematic of the synthesis of DN hydrogels. c Schematic diagram of the synthesis of clay NPs/PNIPAMNC. Reproduced with permission [112]. Copyright 2002, Wiley‐VCHCC BY · PubMed Central
Fig. 3 Main approaches for producing conductive hydrogels. Reproduced with permission [127]. Copyright 2020, Royal Society of Chemistry
Fig. 3 Main approaches for producing conductive hydrogels. Reproduced with permission [127]. Copyright 2020, Royal Society of ChemistryCC BY · PubMed Central
Fig. 4 a Encapulation: a1 Schematic diagram of elastomer encapsulated hydrogel; a2 Variation of the weight ratio of hydrogel and hydrogel-elastomer hybrid with time. Reproduced with permission [151]. Copyright 2016, Springer Nature. b Adding hygroscopic salts: b1 Schematic structure of LiBr-PAM/Carr DN hydrogel; b2 Trends in weight of hydrogels with different concentrations of LiBr content over time under room temperature drying environment; b3 DSC spectra of these hydrogels. Reproduced with permission [152]. Copyright 2022, Springer Nature. c Organohydrogel: c1-c2 Schematic diagram of PVA/CNF-Gly preparation method; c3 DSC spectra of the organohydrogels with different CNF contents; c4 Weight trends over time for organic hydrogels with different CNF contents under high temperature and dry conditions. Reproduced with permission [67]. Copyright 2022, Wiley‐VCH
Fig. 4 a Encapulation: a1 Schematic diagram of elastomer encapsulated hydrogel; a2 Variation of the weight ratio of hydrogel and hydrogel-elastomer hybrid with time. Reproduced with permission [151]. Copyright 2016, Springer Nature. b Adding hygroscopic salts: b1 Schematic structure of LiBr-PAM/Carr DN hydrogel; b2 Trends in weight of hydrogels with different concentrations of LiBr content over time under room temperature drying environment; b3 DSC spectra of these hydrogels. Reproduced with permission [152]. Copyright 2022, Springer Nature. c Organohydrogel: c1-c2 Schematic diagram of PVA/CNF-Gly preparation method; c3 DSC spectra of the organohydrogels with different CNF contents; c4 Weight trends over time for organic hydrogels with different CNF contents under high temperature and dry conditions. Reproduced with permission [67]. Copyright 2022, Wiley‐VCHCC BY · PubMed Central
Fig. 5 Schematic of self-healing mechanisms
Fig. 5 Schematic of self-healing mechanismsCC BY · PubMed Central
Fig. 6 a Schematic of a simple hydrogel-based gas sensor and its sensing process. Reproduced with permission [67]. Copyright 2023, Wiley‐VCH. b Schematic of the sensing mechanism of hydrogel for NO2 sensing. c SEM image of the Ag anode after prolonged NO2 sensing, indicating the generation of an AgCl layer. d Schematic of the electrode-masking experimental setup. e Real-time current curves of the hydrogel sensor for different NO2 concentrations when the anode or cathode is encapsulated. f Dynamic response curves of the hydrogel sensors with different numbers of Ag electrode turns to different NO2 concentrations. Reproduced with permission [150]. Copyright 2021, Wiley‐VCH. g Effect of anode material change on the sensitivity of hydrogel-based NO2 sensors. Reproduced with permission [69]. Copyright 2022, Royal Society of Chemistry
Fig. 6 a Schematic of a simple hydrogel-based gas sensor and its sensing process. Reproduced with permission [67]. Copyright 2023, Wiley‐VCH. b Schematic of the sensing mechanism of hydrogel for NO2 sensing. c SEM image of the Ag anode after prolonged NO2 sensing, indicating the generation of an AgCl layer. d Schematic of the electrode-masking experimental setup. e Real-time current curves of the hydrogel sensor for different NO2 concentrations when the anode or cathode is encapsulated. f Dynamic response curves of the hydrogel sensors with different numbers of Ag electrode turns to different NO2 concentrations. Reproduced with permission [150]. Copyright 2021, Wiley‐VCH. g Effect of anode material change on the sensitivity of hydrogel-based NO2 sensors. Reproduced with permission [69]. Copyright 2022, Royal Society of ChemistryCC BY · PubMed Central
Fig. 7 a-d Complex impedance plots of the PAA/GA sensor at different humidity values with or without 50 ppm NH3. e Complex impedance plot of the PAA/GA sensor with different NH3 concentrations at 80% RH. f Impedance modulus of the PAA/GA sensors with and without 50 ppm NH3 at different humidity levels. NH3 sensing mechanism of PAA/GA: g at low RH values, h at moderate RH values, and i at high RH values. Reproduced with permission [72]. Copyright 2021, Elsevier
Fig. 7 a-d Complex impedance plots of the PAA/GA sensor at different humidity values with or without 50 ppm NH3. e Complex impedance plot of the PAA/GA sensor with different NH3 concentrations at 80% RH. f Impedance modulus of the PAA/GA sensors with and without 50 ppm NH3 at different humidity levels. NH3 sensing mechanism of PAA/GA: g at low RH values, h at moderate RH values, and i at high RH values. Reproduced with permission [72]. Copyright 2021, ElsevierCC BY · PubMed Central
Fig. 8 a Schematic diagram of the selectivity of SnO2/RGOH for NO2. b Diagram of microheater. Reproduced with permission [210]. Copyright 2020, American Chemical Society. c Comparison of the response ability of the original hydrogel and the self-healed hydrogel to NO2. Reproduced with permission [150]. Copyright 2021, Wiley‐VCH. d Schematic of wireless sensing and alarm for NO2. d1-d4 Sensor alarm process for 2 ppm NO2: when the current exceeds the threshold, the red light comes on and the buzzer sounds. d5-d7 Wireless reception of NO2 sensing signals on a smartphone. Reproduced with permission [69]. Copyright 2022, Royal Society of Chemistry. e Real‐time responses of the PVA–CNF DN organohydrogel towards 0.4–2 ppm NO2 at 25, − 10 and − 20 °C. Reproduced with permission [67]. Copyright 2022, Wiley‐VCH. f Structure of self-powered NO2 sensor/power source. g Schematic diagram of self-powered NO2 sensing system. Reproduced with permission [214]. Copyright 2023, Wiley‐VCH
Fig. 8 a Schematic diagram of the selectivity of SnO2/RGOH for NO2. b Diagram of microheater. Reproduced with permission [210]. Copyright 2020, American Chemical Society. c Comparison of the response ability of the original hydrogel and the self-healed hydrogel to NO2. Reproduced with permission [150]. Copyright 2021, Wiley‐VCH. d Schematic of wireless sensing and alarm for NO2. d1-d4 Sensor alarm process for 2 ppm NO2: when the current exceeds the threshold, the red light comes on and the buzzer sounds. d5-d7 Wireless reception of NO2 sensing signals on a smartphone. Reproduced with permission [69]. Copyright 2022, Royal Society of Chemistry. e Real‐time responses of the PVA–CNF DN organohydrogel towards 0.4–2 ppm NO2 at 25, − 10 and − 20 °C. Reproduced with permission [67]. Copyright 2022, Wiley‐VCH. f Structure of self-powered NO2 sensor/power source. g Schematic diagram of self-powered NO2 sensing system. Reproduced with permission [214]. Copyright 2023, Wiley‐VCHCC BY · PubMed Central
Fig. 9 a Response of PAM/CArr DN hydrogel to NH3 in different tensile strains. Reproduced with permission [70]. Copyright 2020, American Chemical Society. b Response (purple column) of PAA/GA sensor to NH3 and other interfering gases. Reproduced with permission [72]. Copyright 2021, Elsevier. c-d NH3 sensing mechanism of PGA/GA sensors: c at low RH values and b at high RH values. Reproduced with permission [71]. Copyright 2020, Elsevierc. e Diagram of the breath testing process for NH3. f Response of hydrogels to exhalation with different NH3 contents. Reproduced with permission [76]. Copyright 2021, Elsevier
Fig. 9 a Response of PAM/CArr DN hydrogel to NH3 in different tensile strains. Reproduced with permission [70]. Copyright 2020, American Chemical Society. b Response (purple column) of PAA/GA sensor to NH3 and other interfering gases. Reproduced with permission [72]. Copyright 2021, Elsevier. c-d NH3 sensing mechanism of PGA/GA sensors: c at low RH values and b at high RH values. Reproduced with permission [71]. Copyright 2020, Elsevierc. e Diagram of the breath testing process for NH3. f Response of hydrogels to exhalation with different NH3 contents. Reproduced with permission [76]. Copyright 2021, ElsevierCC BY · PubMed Central
Fig. 10 a1 Response to 1% O2 under different tensile strains. a2 Response of original and self-healed organohydrogels to 1% O2. a3 Photographs showing the organohydrogel (marked by the yellow circle) adhered firmly to various materials. a4 Real-time response curve of the sensor to human exhalation in the air. a5 Diagram of the breath testing process for O2. Reproduced with permission [77]. Copyright 2022, Springer Nature. SEM of b1 PI film and b2 hydrogel on artificial skin. b3 Schematic diagram of the tcPO2 sensing device and sensing process. b4 Illustration of placing the sensor on the foot to measure tcPO2. b5-b6 Test results of tcPO2 sensing when the foot is in different states. Reproduced with permission [230]. Copyright 2021, American Association for the Advancement of Science
Fig. 10 a1 Response to 1% O2 under different tensile strains. a2 Response of original and self-healed organohydrogels to 1% O2. a3 Photographs showing the organohydrogel (marked by the yellow circle) adhered firmly to various materials. a4 Real-time response curve of the sensor to human exhalation in the air. a5 Diagram of the breath testing process for O2. Reproduced with permission [77]. Copyright 2022, Springer Nature. SEM of b1 PI film and b2 hydrogel on artificial skin. b3 Schematic diagram of the tcPO2 sensing device and sensing process. b4 Illustration of placing the sensor on the foot to measure tcPO2. b5-b6 Test results of tcPO2 sensing when the foot is in different states. Reproduced with permission [230]. Copyright 2021, American Association for the Advancement of ScienceCC BY · PubMed Central
Fig. 11 a-c Diagram of the human olfactory system for olfactory signal transmission. d-f Diagram of the sensing process of the colorimetric hydrogel sensor on the target substance. g Structure and h fabrication of colorimetric hydrogel sensor. Reproduced with permission [250]. Copyright 2020, Wiley–VCH
Fig. 11 a-c Diagram of the human olfactory system for olfactory signal transmission. d-f Diagram of the sensing process of the colorimetric hydrogel sensor on the target substance. g Structure and h fabrication of colorimetric hydrogel sensor. Reproduced with permission [250]. Copyright 2020, Wiley–VCHCC BY · PubMed Central
Fig. 12 a Swelling/contraction of CS hydrogel under different humidity conditions. Reproduced with permission [267]. Copyright 2022, American Association for the Advancement of Science. b–d Complex EIS spectra of the humidity sensor under different RH environments. e Dynamic response curves of the thin-film and bulk hydrogels at different RH values. f Variations in the thickness of hydrogel with the spin-coating speed. g Dynamic response curves of the hydrogel films of different thicknesses at different RH values. Reproduced with permission [206]. Copyright 2022, Springer Nature
Fig. 12 a Swelling/contraction of CS hydrogel under different humidity conditions. Reproduced with permission [267]. Copyright 2022, American Association for the Advancement of Science. b–d Complex EIS spectra of the humidity sensor under different RH environments. e Dynamic response curves of the thin-film and bulk hydrogels at different RH values. f Variations in the thickness of hydrogel with the spin-coating speed. g Dynamic response curves of the hydrogel films of different thicknesses at different RH values. Reproduced with permission [206]. Copyright 2022, Springer NatureCC BY · PubMed Central
Fig.13 a Optical responses (reflection spectra) of hydrogel sensors in different RH values. b CIE 1931 color space of the XY values converted from the reflection spectra. c Hydrogel sensors for high-resolution displays: the color of the display changes with the ambient humidity. Reproduced with permission [267]. Copyright 2022, American Association for the Advancement of Science. d Responses of the DN hydrogel and EG/Gly-DN organohydrogels to different RH values. e Response of the Gly-DN organohydrogel to low RH values. f Response/recovery time of respiration monitoring. Reproduced with permission [270]. Copyright 2019, Royal Society of Chemistry
Fig.13 a Optical responses (reflection spectra) of hydrogel sensors in different RH values. b CIE 1931 color space of the XY values converted from the reflection spectra. c Hydrogel sensors for high-resolution displays: the color of the display changes with the ambient humidity. Reproduced with permission [267]. Copyright 2022, American Association for the Advancement of Science. d Responses of the DN hydrogel and EG/Gly-DN organohydrogels to different RH values. e Response of the Gly-DN organohydrogel to low RH values. f Response/recovery time of respiration monitoring. Reproduced with permission [270]. Copyright 2019, Royal Society of ChemistryCC BY · PubMed Central
Fig. 14 Response of the humidity sensor to a regular and b irregular breath. Response to c finger bending, d knee bending at different frequency, e pulse at the wrist and f vocal cord vibration. Reproduced with permission [276]. Copyright 2021, Elsevier. g CGCN sensors identify different patterns of breathing. h Bending finger and i touching intermittently at – 25 °C. Reproduced with permission [78]. Copyright 2021, Elsevier
Fig. 14 Response of the humidity sensor to a regular and b irregular breath. Response to c finger bending, d knee bending at different frequency, e pulse at the wrist and f vocal cord vibration. Reproduced with permission [276]. Copyright 2021, Elsevier. g CGCN sensors identify different patterns of breathing. h Bending finger and i touching intermittently at – 25 °C. Reproduced with permission [78]. Copyright 2021, ElsevierCC BY · PubMed Central
Fig. 15 a1 Comparison of humidity response of film and block hydrogels. a2 Comparison of the response of different sensitive sources. Reproduced with permission [152]. Copyright 2022, Springer Nature. b1 Comparison of the response of different sensitive sources. b2 Schematic diagram of the handheld breath test. b3 Real-time response curve of handheld breath test in different breathing modes. b4 Schematic diagram of the mask breathing test. b5 Real-time response curve of the mask breathing test in different breathing modes. Reproduced with permission [277]. Copyright 2023, Wiley‐VCH. c1-c2 Monitoring of “normal breathing” and “apnea” with smart masks. Reproduced with permission [206]. Copyright 2022, Springer Nature
Fig. 15 a1 Comparison of humidity response of film and block hydrogels. a2 Comparison of the response of different sensitive sources. Reproduced with permission [152]. Copyright 2022, Springer Nature. b1 Comparison of the response of different sensitive sources. b2 Schematic diagram of the handheld breath test. b3 Real-time response curve of handheld breath test in different breathing modes. b4 Schematic diagram of the mask breathing test. b5 Real-time response curve of the mask breathing test in different breathing modes. Reproduced with permission [277]. Copyright 2023, Wiley‐VCH. c1-c2 Monitoring of “normal breathing” and “apnea” with smart masks. Reproduced with permission [206]. Copyright 2022, Springer NatureCC BY · PubMed Central
Fig. 16 a Output voltage of I-skin at different RH. b Humidity sensitivity of I-skin. c Output voltage of I-skin at 99% RH and 20% RH alternately. d Output voltage variation curve of I-skin under different breathing modes. e Diagram of finger distance perception by I-skin through humidity change. f Variation of output voltage of I-skin at different finger distances. Reproduced with permission [79]. Copyright 2022, American Chemical Society
Fig. 16 a Output voltage of I-skin at different RH. b Humidity sensitivity of I-skin. c Output voltage of I-skin at 99% RH and 20% RH alternately. d Output voltage variation curve of I-skin under different breathing modes. e Diagram of finger distance perception by I-skin through humidity change. f Variation of output voltage of I-skin at different finger distances. Reproduced with permission [79]. Copyright 2022, American Chemical SocietyCC BY · PubMed Central

Verification

Claims the paper makes

58 Valid · 11 Not valid · 136 Not checked · 82 Own results and interpretations

108 more claims · 18 with their cited sources checked

Create a free account to see all 287 claims and to verify the 24 references still open.

See all claims — free account
  • It may state two separate claims as one. 159
  • Probably not a substantial claim. 29
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Citations

Cites

Show all 286 references

Cited by

See all 236

Metadata

Authors
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J.
Affiliations
Sun Yat-sen University (CN)
Corresponding author
Wu, Jin
Venue
Nano-Micro Letters
Published
2023-05-24
Volume
15
Issue
1
Pages
136-136
ISSN
  • 2150-5551 (ISSN-L)
  • 2311-6706
OpenAlex
W4378070105
Cited by
236
References
289
Citations by year
2026: 55 · 2025: 97 · 2024: 68 · 2023: 16
FWCI
3.97
Type
journal article
Language
en
Open access
Licence
Locations
  • Nano-Micro Letters (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
Shanghai Jiao Tong University
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Biomaterials › Hydrogels: synthesis, properties, applications
Keywords
hydrogel-based sensors, wearable sensors, gas sensors, humidity sensor, vapor sensing, functionalized hydrogels, personal health monitoring, self-healing hydrogels, stretchable sensors, home health care

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. https://app.cochat.ai/papers/10.1007/s40820-023-01109-2
The paper
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023). Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors. Nano-Micro Letters. https://doi.org/10.1007/s40820-023-01109-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.