The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Optimal Jamar Dynamometer Handle Position to Assess Maximal Isometric Hand Grip Strength in Epidemiological Studies
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roberts, H. C., Denison, H. J., Martin, H. J., Patel, H. P., Syddall, H., Cooper, C., & Sayer, A. A. (2011) · Age and Ageing · doi:10.1093/ageing/afr051 · Cited by 3,001
Objectively measured physical capability levels and mortality: systematic review and meta-analysis
Cooper, R., Kuh, D., Hardy, R., Mortality Review Group, & teams, O. B. O. T. F. A. H. S. (2010) · BMJ · doi:10.1136/bmj.c4467 · Cited by 1,166
Hand-Grip Dynamometry Predicts Future Outcomes in Aging Adults
Bohannon, R. W. (2008) · Journal of Geriatric Physical Therapy · doi:10.1519/00139143-200831010-00002 · Cited by 948
Cited by
Differences in handgrip strength protocols to identify sarcopenia and frailty - a systematic review
Sousa-Santos, A. R., & Amaral, T. F. (2017) · BMC Geriatrics · doi:10.1186/s12877-017-0625-y · Cited by 273
Eisenga, M. F., Gomes-Neto, A. W., van Londen, M., Ziengs, A. L., Douwes, R. M., Stam, S. P., Osté, M. C. J., Knobbe, T. J., Hessels, N. R., Buunk, A. M., et al. (2018) · BMJ Open · doi:10.1136/bmjopen-2018-024502 · Cited by 141
“Furthermore, to create uniformity among assessments, the second handle position of the hand dynamometer will be used, which has been shown to be the most accurate position.(20) Lung function will be measured by means of an Asma-1 handheld spirometer (Vitalograph, Buckingham, UK).”
MethodHandgrip strength: a comparison of values obtained from the NHANES and NIH Toolbox studies
Bohannon, R. W., Wang, Y.-C., Yen, S.-C., & Grogan, K. A. (2019) · American Journal of Occupational Therapy · doi:10.5014/ajot.2019.029538 · Cited by 72
“Moreover, the NHANES protocol calls for adjustment of the handle position and three trials, both of which require additional time and are not necessary (Trampisch et al., 2012).”
BackgroundMethodInfluentialFactor, S., Druckmann, I., Atlan, F., Rosenblatt, Y., Tordjman, D., Krespi, R., Kazum, E., Pritsch, T., & Eisenberg, G. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12051866 · Cited by 20
Goudie, S., Dixon, D., McMillan, G., Ring, D., & McQueen, M. (2018) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999.0000000000000095 · Cited by 20
“Grip strength on both the injured and uninjured sides was measured in kilograms with a standard, adjustable handle Jamar dynamometer (Sammons Preston Rolyan, Bolingbrook, IL, USA) set to the second rung position, the optimal setting for measuring grip strength with this instrument [53], the elbow at 90° flexion, and t…”
Method
Metadata
- Authors
- Trampisch, U. S., Franke, J., Jedamzik, N., Hinrichs, T., & Platen, P.
- Venue
- The Journal of Hand Surgery
- Publisher
- Elsevier BV
- Published
- 2012-11
- Volume
- 37
- Issue
- 11
- Pages
- 2368-2373
- ISSN
- 0363-5023 (ISSN-L)
- OpenAlex
- W2088372249
- Cited by
- 238
- References
- 3
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal Jamar Dynamometer Handle Position to Assess Maximal Isometric Hand Grip Strength in Epidemiological Studies. https://app.cochat.ai/papers/10.1016/j.jhsa.2012.08.014
- The paper
- Trampisch, U. S., Franke, J., Jedamzik, N., Hinrichs, T., & Platen, P. (2012). Optimal Jamar Dynamometer Handle Position to Assess Maximal Isometric Hand Grip Strength in Epidemiological Studies. The Journal of Hand Surgery. https://doi.org/10.1016/j.jhsa.2012.08.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.