Differences in adsorption of serum proteins and production of IL-1ra by human monocytes incubated in different tissue culture microtiter plates

Clinchy, Birgitta, Reza Youssefi, M., Håkansson, Leif·2003·Journal of Immunological Methods

Abstract

In vitro cell culture models can be of great value in order to further analyze the regulatory mechanisms underlying the inappropriate function of the immune system in diseases such as autoimmunity and cancer. Cell culture conditions have to be well controlled in a way that they mirror the in vivo situation. The objective of this study was to compare tissue culture microtiter plates from different manufacturers with respect to their ability to support monokine production by human monocytes cultured in human serum. Tissue culture ware, made of polystyrene, undergoes treatment by the manufacturers to make the surface more suitable for culture of adherent cell populations. It is possible that quality differences in this treatment can lead to variations in protein binding properties and thereby influence the adherence and functional properties of monocytes. We measured spontaneous interleukin-1 receptor antagonist (IL-1ra) production by peripheral blood monocytes, cultured in human serum, in five different microtiter plates made for adherent cell culture. Culture in plates from two of the five manufacturers resulted in significantly lower amounts of secreted IL-1ra. IL-1ra release by human monocytes can be induced by adherent IgG cross-linking membrane receptors for the Fc part of IgG (FcgammaR). We found that reduced IL-1ra production coincided with a reduced capacity for binding of serum IgG in one case. Furthermore, this brand of microtiter plate also displayed the lowest level…

Integrity signals

Registry

Crossref · 10.1016/j.jim.2003.07.013

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Monocyte adhesion, cytokine release, maturation of oocytes, and differentiation of neurons can be significantly affected by different types of plastic and different plastic manufacturing processes.

    “It has been shown that monocyte adhesion, cytokine release, maturation of oocytes, and differentiation of neurons, to name just a few, can be significantly affected by different types of plastic and different plastic manufacturing processes (Shen and Horbett, 2001; Brodbeck et al., 2002; Clinchy et al., 2003; Schildknecht et al., 2009).”

    From In Vitro research Reproducibility: Keeping up High Standards (2019) · cites this paper as Clinchy et al., 2003

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Clinchy, B., Reza Youssefi, M., & Håkansson, L.
Affiliations
Linköping University Hospital (SE)
Corresponding author
Clinchy, Birgitta
Venue
Journal of Immunological Methods
Publisher
Elsevier BV
Published
2003-11
Volume
282
Issue
1-2
Pages
53-61
ISSN
0022-1759 (ISSN-L)
OpenAlex
W2095325862
Cited by
10
References
1
Citations by year
2025: 1 · 2023: 1 · 2019: 1 · 2014: 1 · 2013: 1 · 2012: 1
FWCI
0.26
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Immunological Methods (publishedVersion)
  • PubMed (publishedVersion)
Funders
Linköpings Universitet
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Monoclonal and Polyclonal Antibodies Research
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Life Sciences › Immunology and Microbiology › Immunology › T-cell and B-cell Immunology
Keywords
serum protein adsorption, interleukin-1 receptor antagonist, human monocytes, albumin adsorption, Fc gamma receptor, polystyrene
MeSH terms
Adsorption, Blood Proteins, Cells, Cultured, Humans, Immunoglobulin G, Monocytes, Sialoglycoproteins, Interleukin 1 Receptor Antagonist Protein

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review