CoChat

ELISA for human serum leucine-rich alpha-2-glycoprotein-1 employing cytochrome c as the capturing ligand

Open access
Weivoda, Starchild, Andersen, John D., Skogen, Aunica, Schlievert, Patrick M., Fontana, Donna, Schacker, Timothy, Tuite, Paul, Dubinsky, Janet M., Jemmerson, Ronald · 2008 · Journal of Immunological Methods
Cited by 63

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Leucine-rich alpha-2-glycoprotein-1 (LRG) is a serum glycoprotein of unknown function that has shown promise based on qualitative assessments as a biomarker for certain diseases including microbial infections and cancer. However, the lack of a quantitative assay for LRG has limited its application. Here an indirect enzyme-linked immunosorbent assay (ELISA) for quantifying LRG in human serum is described in which cytochrome c is employed as the capturing ligand and a monoclonal antibody specific for LRG is used to detect the captured glycoprotein. Application of this assay in quantifying LRG in various patients' sera is demonstrated. The concentration of LRG in sera of control subjects as determined by this assay is approximately 50 μg/ml. Consistent with expectations from published reports, LRG was found to be significantly elevated in the sera of some patients with a bacterial infection (toxic shock syndrome, TSS). LRG was only slightly elevated in patients infected with the human immunodeficiency virus as compared to uninfected control subjects, while normal levels of LRG were observed in patients with non-infectious diseases (inflammatory arthritis and neurological disorders, primarily Parkinson's disease). Although LRG and C-reactive protein (CRP) are both produced by the liver and are classified as acute-phase proteins, there was no significant correlation between the levels of LRG and CRP in the sera of the patients. Thus, LRG and CRP measurements are non-redundant and indicate different physiological contexts. The ELISA described in this report should be useful to further assess serum LRG as a biomarker for clinical diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jim.2008.03.004

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 63

Metadata

Authors
Weivoda, S., Andersen, J. D., Skogen, A., Schlievert, P. M., Fontana, D., Schacker, T., Tuite, P., Dubinsky, J. M., & Jemmerson, R.
Venue
Journal of Immunological Methods
Publisher
Elsevier BV
Published
2008-07
Volume
336
Issue
1
Pages
22-29
ISSN
0022-1759 (ISSN-L)
OpenAlex
W2164443190
Cited by
63
References
2
FWCI
2.06
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.